A porous microneedle electrochemical glucose sensor fabricated on a scaffold of a polymer monolith
Source abstract
Abstract
Abstract Porous microneedle electrodes with pores of ∼1 µ m diameter were fabricated by electroless plating of nickel followed by gold on a polymer monolith of poly(glycidyl methacrylate). The specific surface area of the fabricated electrode evaluated by the Brunauer–Emmett–Teller method was 2.559 ± 0.050 m 2 g −1 (standard error of mean), while that of the non-porous control was <0.001 m 2 g −1 . Electrochemical glucose sensors were then fabricated by immobilizing glucose oxidase on the gold-plated microneedle electrodes. The sensitivity of the porous microneedle glucose sensor between 0 and 15 mM glucose was 22.99 ± 0.72 µ A mM −1 , and that of the non-porous control was 3.16 ± 0.56 µ A mM −1 . The amperometry of glucose concentration in solution was demonstrated using the fabricated electrode as a working electrode, along with an Ag/AgCl reference electrode and gold counter electrode both of which were made of microneedles. These results indicate the advantages of porous structures for electrochemical sensing with increased sensitivity.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Advancements in Transdermal Drug Delivery · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Microneedles for transdermal drug delivery10.1016/j.addr.2003.10.023 ↗
2. Epidermal electronics10.1126/science.1206157 ↗
3. Wearable chemical sensors: present challenges and future prospects10.1021/acssensors.6b00250 ↗
4. Hydrogel-forming microneedle arrays allow detection of drugs and glucose in vivo: potential for use in diagnosis and therapeutic drug monitoring10.1371/journal.pone.0145644 ↗
5. A swellable microneedle patch to rapidly extract skin interstitial fluid for timely metabolic analysis10.1002/adma.201702243 ↗
6. Microneedle-based self-powered glucose sensor10.1016/j.elecom.2014.07.014 ↗
7. Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring10.1007/s00216-016-9961-6 ↗
8. Use of microneedle array devices for continuous glucose monitoring: a review10.1089/dia.2012.0188 ↗
9. A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring10.1039/C8AY00264A ↗
10. Porous polymer microneedles with interconnecting microchannels for rapid fluid transport10.1039/C6RA07882F ↗
11. Novel monolithic materials using poly(ethylene glycol) as porogen for protein separation10.1016/j.polymer.2006.01.096 ↗
12. Organic electrochromic timer for enzymatic skin patches10.1016/j.bios.2018.07.013 ↗
13. An array of porous microneedles for transdermal monitoring of intercellular swelling10.1007/s10544-017-0207-y ↗
14. Metallic microneedles with interconnected porosity: a scalable platform for biosensing and drug delivery10.1016/j.actbio.2018.09.007 ↗
15. Nanoporous gyroid platinum with high catalytic activity from block copolymer templates via electroless plating10.1038/am.2015.13 ↗
16. Exceptionally high glucose current on a hierarchically structured porous carbon electrode with ‘wired’ flavin adenine dinucleotide-dependent glucose dehydrogenase10.1021/ja5053736 ↗
17. Synthesis of monodisperse nickel-coated polymer particles by electroless plating method utilizing functional polymeric ligands10.1002/app.23807 ↗
18. A practical three-step synthesis of vinylferrocene10.1055/s-0036-1589142 ↗
19. Characterization of poly(vinylferrocene-co-2-hydroxyethyl methacrylate) for use as electron mediator in enzymatic glucose sensor10.1016/S1381-5148(97)00146-6 ↗
20. Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensor10.1016/j.snb.2005.01.003 ↗
21. Microneedle array-based carbon paste amperometric sensors and biosensors10.1039/c1an00012h ↗
22. Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring10.1016/j.sbsr.2016.10.004 ↗
23. Minimally-invasive microneedle-based biosensor array for simultaneous lactate and glucose monitoring in artificial interstitial fluid10.1002/elan.201800630 ↗
24. Use of flash glucose-sensing technology (FreeStyle Libre) in youth with type 1 diabetes: AWeSoMe study group real-life observational experience10.1007/s00592-018-1218-8 ↗