journal article·2026-02-19Open access

Lowering of Proton and Deuteron Mean Kinetic Energy in the LiTFSI Water-in-Salt Electrolyte System

Mi Zhang, Andrew G. Seel, Patrick L. Cullen

Abstract

High Resolution Image Download MS PowerPoint Slide Water-in-salt electrolytes have emerged as promising materials for energy storage devices, significantly extending the electrochemical stability window of water through confinement within a salt matrix. While the structure and distribution of water molecules in these systems is becoming increasingly better characterized, the molecular nature and energetics of water present a greater challenge. Measurement of the quantum kinetic energy of light atoms is a sensitive probe of their environment, reflecting the potential experienced by the atoms and inclusive of their zero-point energy. It is found that the mean kinetic energy of the proton and deuteron in the archetypal water-in-salt electrolyte system, LiTFSI-H 2 O, decreases as a function of salt concentration. This indicates that while the disruption of the hydrogen bond network of water is known to lead to an increasing OH stretching frequency, other components to the quantum kinetic energy must decrease to result in the overall lower measured average.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Battery Materials and Technologies · Spectroscopy and Quantum Chemical Studies · Electrostatics and Colloid Interactions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Engineering and Materials Science

Queen Mary University of London

ISIS Spallation Neutron and Muon Source

Rutherford Appleton Laboratory

Department of Physics

Royal Holloway University of London

Funding

Science and Technology Facilities Council

References (26)

Show source-provided references
1. 10.1126/science.aab159510.1126/science.aab1595 ↗
2. 10.1038/nenergy.2016.12910.1038/nenergy.2016.129 ↗
3. 10.1002/adfm.20242588510.1002/adfm.202425885 ↗
4. 10.1021/acs.jpcb.1c0675910.1021/acs.jpcb.1c06759 ↗
5. 10.1080/0001873050040313610.1080/00018730500403136 ↗
6. 10.1080/00018732.2017.131796310.1080/00018732.2017.1317963 ↗
7. 10.1063/1.314270010.1063/1.3142700 ↗
8. 10.1103/PhysRevLett.106.25550210.1103/PhysRevLett.106.255502 ↗
9. 10.1103/PhysRevB.86.10430810.1103/PhysRevB.86.104308 ↗
10. 10.1021/jz401538r10.1021/jz401538r ↗
11. 10.1103/PhysRevLett.100.17780110.1103/PhysRevLett.100.177801 ↗
12. 10.1103/PhysRevLett.100.12780210.1103/PhysRevLett.100.127802 ↗
13. 10.1590/S0103-9733200900030001410.1590/S0103-97332009000300014 ↗
14. 10.1021/acs.jpclett.0c0254710.1021/acs.jpclett.0c02547 ↗
15. 10.1063/1.278943610.1063/1.2789436 ↗
16. 10.1039/c0cp02479a10.1039/c0cp02479a ↗
17. 10.1007/s11467-017-0699-110.1007/s11467-017-0699-1 ↗
18. 10.1103/PhysRevB.85.04540310.1103/PhysRevB.85.045403 ↗
19. 10.1103/PhysRevLett.116.16780210.1103/PhysRevLett.116.167802 ↗
20. 10.1063/5.002192610.1063/5.0021926 ↗
21. 10.1088/0957-0233/23/4/04590210.1088/0957-0233/23/4/045902 ↗
22. 10.1016/S0168-9002(01)01335-310.1016/S0168-9002(01)01335-3 ↗
23. 10.1039/C9CP06483D10.1039/C9CP06483D ↗
24. 10.1021/acsenergylett.4c0302210.1021/acsenergylett.4c03022 ↗
25. 10.1039/D5EB00105F10.1039/D5EB00105F ↗
26. 10.1021/acs.jpcb.1c0218910.1021/acs.jpcb.1c02189 ↗