journal article·2022-09-01

Site-Selective Ion Intercalation Controls Spectral Response in Electrochromic Hexagonal Tungsten Oxide Nanocrystals

Benjamin Z. Zydlewski, Hsin-Che Lu, Hugo Celio, Delia J. Milliron

The Journal of Physical Chemistry C· Volume 126· Issue 34
Publisher page

Abstract

The electrochromism of tungsten oxide occurs through electrochemical reduction, providing active solar control to smart windows, but control over the spectral response is limited and largely empirical. To determine how specific chemical changes result in the optical absorption processes responsible for coloration, we pair structurally well-defined electrochromic nanocrystals (NCs) with cations of varying ionic radii to limit intercalation into specific crystallographic sites. The localized surface plasmon absorption of hexagonal cesium-doped tungsten oxide (Cs:WO 3 ) NCs is enhanced, and new absorption features appear, depending on how the cations intercalate into various interstitial voids. These differences were rationalized using X-ray photoelectron and Raman spectroscopies to reveal the chemical and structural changes leading to the observed variations in the electrochemically induced absorption spectra. Smaller cations, Na + and Li +, can access additional interstitial sites, leading to a secondary, polaronic mechanism of electrochromism, accounting for enhanced visible light absorption.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Transition Metal Oxide Nanomaterials · Gas Sensing Nanomaterials and Sensors · Ga2O3 and related materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States

McKetta Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States

Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States

Funding

Welch Foundation · National Science Foundation · Companhia Brasileira de Metalurgia e Minera??o

References (52)

Show source-provided references
1. 10.1002/aelm.20180018510.1002/aelm.201800185 ↗
2. 10.1016/j.electacta.2017.11.16910.1016/j.electacta.2017.11.169 ↗
3. 10.1016/j.solmat.2019.02.04110.1016/j.solmat.2019.02.041 ↗
4. 10.1016/j.buildenv.2015.02.02110.1016/j.buildenv.2015.02.021 ↗
5. 10.1063/1.280083810.1063/1.2800838 ↗
6. 10.1016/j.ssi.2003.08.01710.1016/j.ssi.2003.08.017 ↗
7. 10.1021/acsenergylett.0c0123610.1021/acsenergylett.0c01236 ↗
8. 10.1021/acs.nanolett.7b0273010.1021/acs.nanolett.7b02730 ↗
9. 10.1021/acs.chemrev.7b0061310.1021/acs.chemrev.7b00613 ↗
10. 10.1021/jp001003110.1021/jp0010031 ↗
11. 10.1002/adom.20120005110.1002/adom.201200051 ↗
12. 10.1063/1.9541510.1063/1.95415 ↗
13. 10.1021/cm800668x10.1021/cm800668x ↗
14. 10.1557/jmr.2012.2510.1557/jmr.2012.25 ↗
15. 10.1021/acs.chemmater.5b0398010.1021/acs.chemmater.5b03980 ↗
16. 10.1016/S0925-8388(96)02470-X10.1016/S0925-8388(96)02470-X ↗
17. 10.1021/acs.nanolett.0c0005210.1021/acs.nanolett.0c00052 ↗
18. 10.1021/acsanm.1c0021510.1021/acsanm.1c00215 ↗
19. 10.1021/acs.nanolett.6b0139010.1021/acs.nanolett.6b01390 ↗
20. 10.1021/cm403063810.1021/cm4030638 ↗
21. 10.1107/S002188981103897010.1107/S0021889811038970 ↗
22. Celio, H. Interface Designed with Differential Pumping and Built-in Figure of Merit Method to Monitor Chambers Where Environmentally Sensitive Samples Are Prepared and Transferred for Analysis. 9945761, April 17, 2018.
23. 10.1038/s41563-018-0130-510.1038/s41563-018-0130-5 ↗
24. 10.1021/jp301210q10.1021/jp301210q ↗
25. 10.1063/1.508537410.1063/1.5085374 ↗
26. 10.1021/acs.jpcc.6b0293610.1021/acs.jpcc.6b02936 ↗
27. 10.1021/cm803445510.1021/cm8034455 ↗
28. 10.1016/j.electacta.2014.08.09610.1016/j.electacta.2014.08.096 ↗
29. 10.1016/j.apsusc.2015.09.05010.1016/j.apsusc.2015.09.050 ↗
30. 10.1007/BF0088288510.1007/BF00882885 ↗
31. 10.1103/PhysRevB.97.15510210.1103/PhysRevB.97.155102 ↗
32. 10.1103/PhysRevMaterials.3.02500110.1103/PhysRevMaterials.3.025001 ↗
33. 10.1103/PhysRevB.81.16520710.1103/PhysRevB.81.165207 ↗
34. 10.1103/PhysRevB.92.03511010.1103/PhysRevB.92.035110 ↗
35. 10.1063/5.002161310.1063/5.0021613 ↗
36. 10.1021/jacs.1c0873910.1021/jacs.1c08739 ↗
37. 10.1103/PhysRevB.16.69710.1103/PhysRevB.16.697 ↗
38. 10.1021/jp909317210.1021/jp9093172 ↗
39. 10.1016/j.cplett.2005.06.02310.1016/j.cplett.2005.06.023 ↗
40. 10.1039/FT996920213710.1039/FT9969202137 ↗
41. 10.1016/j.jallcom.2021.15920010.1016/j.jallcom.2021.159200 ↗
42. 10.1016/S0368-2048(02)00207-410.1016/S0368-2048(02)00207-4 ↗
43. 10.1021/acs.accounts.9b0028710.1021/acs.accounts.9b00287 ↗
44. 10.1002/smll.20050026110.1002/smll.200500261 ↗
45. 10.1016/j.elspec.2008.10.00210.1016/j.elspec.2008.10.002 ↗
46. 10.1016/j.elspec.2012.01.00410.1016/j.elspec.2012.01.004 ↗
47. 10.1016/j.nanoen.2020.10572110.1016/j.nanoen.2020.105721 ↗
48. 10.1016/0022-4596(87)90359-810.1016/0022-4596(87)90359-8 ↗
49. 10.1111/jace.1641410.1111/jace.16414 ↗
50. 10.1016/S0167-2738(00)00332-510.1016/S0167-2738(00)00332-5 ↗
51. 10.1016/S0167-2738(99)00338-010.1016/S0167-2738(99)00338-0 ↗
52. 10.1038/s41586-018-0347-010.1038/s41586-018-0347-0 ↗