Overview on the IFMIF test cell development
Source abstract
Abstract
The major components of the test cell are the three test modules, the shield plugs and the test cell covers. The existing drawings of the IFMIF test cell and the internals were put together to have a common basis for discussion. The high-flux-test-module was redesigned. The rigs were designed with a flat plate geometry. They are equipped with an electric heater system, with which the temperatures in the specimens stack can be kept at temperature levels between 250 and 650 °C within a tolerance of 30 °C. The temperature level of each rig can be adjusted independently. First result of the optimization of the medium-flux-test-module are also described.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Superconducting Materials and Applications · Electromagnetic Launch and Propulsion Technology · Fusion materials and technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (3)
Show source-provided references
1. M. Martone (Ed.), IFMIF International fusion materials irradiation facility conceptural design activity final report, ENEA Frascati Report RT/ERG/FUS/96/11, December 1996
2. S. Gordeev, V. Heinzel, K. H. Lang, A. Möslang, K. Schleisiek, V. Slobodtchouk, E. Stratmanns, Optimized design and thermo-hydraulic analyses of the IFMIF/HFTM test section FZK 6895
3. IFMIF-KEP report JAERI-Tech 2003-005, March 2003