Calorimetry in Tore Supra.
Source abstract
Abstract
In the framework of the Tore Supra-CIEL upgrade, designed for steady-state operation, the calorimetric diagnostic implemented in the cooling water loop has been completely rebuilt. Both the techniques used to increase the diagnostic sensitivity and examples of calorimetric analysis are reported. The interest and relevance of such a diagnostic for ITER or other actively cooled machines are briefly discussed.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fusion materials and technologies · Magnetic confinement fusion research · Superconducting Materials and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Vallet · J. Nucl. Mater. · 2001 · 290–293 · 102310.1016/S0022-3115(00)00494-3 ↗
2. J. Wesley, ITER internal report reference S 19 RI 8 97-07-10 F1
3. P. Garin, in: Proceedings of the 20th SOFT, Fusion Technology, vol.2, 1998, p.1709
4. Spuig · Fus. Eng. Des. · 2001 · 56&57 · 99910.1016/S0920-3796(01)00446-X ↗
5. Guillerminet · Fus. Eng. Des. · 2002 · 60 · 42710.1016/S0920-3796(02)00043-1 ↗
6. Mitteau · J. Nucl. Mater. · 1999 · 266–269 · 79810.1016/S0022-3115(98)00843-5 ↗
7. R. Mitteau, J.-C. Vallet, et al., these Proceedings
8. Escourbiac · Fus. Eng. Des. · 2001 · 56&57 · 28510.1016/S0920-3796(01)00301-5 ↗