In-pile testing of ITER first wall mock-ups at relevant thermal loading conditions
Source abstract
Abstract
Abstract The paper describes the experimental technique and preliminary results of thermal fatigue testing of ITER first wall (FW) water-cooled mock-ups inside the core of the RBT-6 experimental fission reactor (RIAR, Dimitrovgrad, Russia). This experiment has provided simultaneous effect of neutron fluence and thermal cycling damages on the mock-ups. A PC-controlled high-temperature graphite ohmic heater was applied to provide cyclic thermal load onto the mock-ups surface. This experiment lasted for 309 effective irradiation days with a final damage level (CuCrZr) of 1 dpa in the mock-ups. About 3700 thermal cycles with a heat flux of 0.4–0.5 MW/m 2 onto the mock-ups were realized before the heater fails. Then, irradiation was continued in a non-cycling mode.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Graphite, nuclear technology, radiation studies · Nuclear Materials and Properties · Nuclear reactor physics and engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (5)
Show source-provided references
1. Litunovsky · Fusion Eng. Des. · 2000 · 51&52 · 80310.1016/S0920-3796(00)00189-7 ↗
2. R. Giniyatulin et al., in: Proceedings of JAERI-Conference 98-001, October 1997, p. 221.
3. Roedig · J. Nucl. Mater. · 2002 · 307–311 · 5310.1016/S0022-3115(02)01030-9 ↗
4. Gervash · Fusion Eng. Des. · 2001 · 56&57 · 38110.1016/S0920-3796(01)00333-7 ↗
5. Gervash · J. Fusion Technol. Am. Nucl. Soc. · 2000 · 38 · 27710.13182/FST00-A36140 ↗