First measurements of main chamber power load during JET disruptions
Source abstract
Abstract
Interaction of the plasma with the main chamber is observed with infrared thermography during disruption of JET plasmas. Taking into account the effect of surface layers on some of the limiter surfaces, we make the first estimates of the energy density deposited on the walls. Assuming toroidal symmetry and extrapolating over the whole JET vessel gives a good energy balance with the pre-disruption stored energy.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnetic confinement fusion research · Fusion materials and technologies · Laser-Plasma Interactions and Diagnostics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Paley · J. Nucl. Mater. · 2005 · 337–339 · 70210.1016/j.jnucmat.2004.10.097 ↗
2. Riccardo · Plasma Phys. Contr. Fusion · 2002 · 44 · 90510.1088/0741-3335/44/6/320 ↗
3. E. Gauthier et al., J. Nucl. Mater., these Proceedings.
4. A. Herrmann and ASDEX Upgrade Team, Europhysics Conference, Abstracts (CD-ROM, Proc. of the 28th EPS Conference on Controlled Fusion and Plasma Physics, Madeira 2001), p. 2109 (2001).
5. Coad · Nucl. Fusion · 2006 · 46 · 35010.1088/0029-5515/46/2/018 ↗
6. Andrew · J. Nucl. Mater · 2003 · 313–316 · 13510.1016/S0022-3115(02)01586-6 ↗
7. Andrew · J. Nucl. Mater. · 2005 · 337–339 · 9910.1016/j.jnucmat.2004.10.145 ↗
8. Nakamura · Plasma Phys. Contr. Fusion · 1996 · 38 · 179110.1088/0741-3335/38/10/007 ↗