Application of lock-in thermography non destructive technique to CFC armoured plasma facing components
Source abstract
Abstract
Abstract A non destructive testing technique – so called modulated photothermal thermography or lock-in thermography – has been set-up for plasma facing components examination. Reliable measurements of phase contrast were obtained on 8 mm carbon fiber composite (CFC) armoured W7-X divertor component with calibrated flaws. A 3D finite element analysis allowed the correlation of the measured phase contrast and showed that a 4 mm strip flaw can be detected at the CFC/copper interface.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Welding Techniques and Residual Stresses · Thermography and Photoacoustic Techniques · Microstructure and Mechanical Properties of Steels
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. Durocher · Fus. Eng. Des. · 2003 · 66–68 · 30510.1016/S0920-3796(03)00175-3 ↗
2. Fouquet · Fus. Eng. Des. · 2006 · 81 · 26510.1016/j.fusengdes.2005.06.363 ↗
3. Traxler · Phys. Script · 2004 · T111 · 20310.1238/Physica.Topical.111a00203 ↗
4. D. Wu, A. Salerno, U. Malter, R. Aoki et al., in: Proc. of QIRT 1996, Edizioni ETS, Pisa, p. 251.
5. Appendino · J. Nuc. Mater. · 2004 · 329–333 · 156310.1016/j.jnucmat.2004.04.313 ↗
6. Boscary · Nucl. Fusion · 2003 · 43 · 83110.1088/0029-5515/43/9/306 ↗
7. Maillet · 2000