Temperature measurement for in-situ crack monitoring under high-frequency loading
Source abstract
Abstract
Abstract A liquid mercury target vessel, composed of type 316L stainless steel and used in a pulsed spallation neutron source, suffers not only from proton and neutron damage but also cyclic impact stresses caused by proton beam-induced pressure waves. In a previous study, we carried out an ultrasonic fatigue test to gigacycles and observed that the specimen surface temperature rose abruptly just before failure. To understand the mechanism of this temperature rise, the temperature distribution of the specimen surface was measured using a thermography instrument during an ultrasonic fatigue test. The result showed that the temperature rose locally, especially at the crack tip, and the peak position moved with crack propagation. Furthermore, nonlinear structural analysis by LS-DYNA was performed to clarify the mechanism of this temperature rise. The analytical results showed that the heat due to plastic deformation at the crack tip is the dominant factor underlying the temperature rise rather than friction between crack surfaces.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Non-Destructive Testing Techniques · Fatigue and fracture mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (17)
Show source-provided references
1. Targetry overview –various target concepts and expectable next generation targets in power frontier applications–
2. Neutron Source Section · 2012
3. Gigacycle fatigue properties for high-strength low-alloy steel at 100 Hz, 600 Hz, and 20 kHz10.1016/S1359-6462(01)01213-1 ↗
4. Evaluation of giga-cycle fatigue properties of austenitic stainless steels using ultrasonic fatigue test10.1299/jmmp.2.366 ↗
5. Investigation of effect of pre-strain on very high-cycle fatigue strength of austenitic stainless steels10.1299/jpes.3.38 ↗
6. Post-irradiation tensile properties of the first and second operational target modules at the spallation neutron source10.1016/j.jnucmat.2014.02.037 ↗
7. Very high cycle fatigue in pulsed high power spallation neutron source10.4028/www.scientific.net/AMR.891-892.536 ↗
8. Gigacycle fatigue behavior of austenitic stainless steels used for mercury target vessel10.1016/j.jnucmat.2015.07.040 ↗
9. Development of self-reference lock-in thermography and its application to remote nondestructive inspection of fatigue cracks in steel brides10.3166/qirt.7.73-84 ↗
10. Infrared thermographic scanning of fatigue in metals10.1016/0029-5493(95)01043-H ↗
11. Fatigue limit evaluation for austenitic stainless steel10.2472/jsms.61.953 ↗
12. Fatigue crack initiation detection by an infrared thermography method10.1111/j.1460-2695.2009.01410.x ↗
13. Application of in situ thermography for evaluating the high-cycle and very high-cycle fatigue behavior of cast aluminium alloy AlSi7Mg(T6)10.1016/j.ultras.2013.03.001 ↗
14. Study of thermal effects associated with crack propagation during very high cycle fatigue tests10.1016/j.actamat.2008.04.023 ↗
15. The prediction of fatigue life using ultrasound testing, in: ultrasonic fatigue
16. Livermore Software Technology Corporation · 2016
17. Coupling possibilities in LS-DYNA: development status and sample applications