journal article·2018-03

Experimental Measurement of Scatter to Primary Ratio by Localized Primary Modulation in Industrial Computed Radiography

Aboutaleb Kermani, Seyed Amir Hossein Feghhi

Publisher page

Abstract

The scatter-to-primary ratio (SPR), can serve as an important parameter for performing the scatter correction procedures or build up factor determination in radiography projections. In this work an experimental technique is presented based on localized primary modulation for direct SPR measurement. As illustrative examples, the SPR is measured for steel and aluminum step wedges to demonstrate the applicability of the presented technique in computed radiography. As a required parameter, the effective transmission factor of the modulator is measured using primary beam stopping concept over a calibration block. This technique has significant advantages such as a straight forward theory, simplified applicability in industrial site conditions, beam hardening consideration as well as automation possibility. The technique works by a single image acquisition, without image data loss in the interested area.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Geophysical Methods and Applications · Radiation Detection and Scintillator Technologies · Microwave Imaging and Scattering Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Rowlands, J.A.: The physics of computed radiography. Phys. Med. Biol. 47(23), R123–R166 (2002). https://doi.org/10.1088/0031-9155/47/23/20110.1088/0031-9155/47/23/201 ↗
2. Correa, S.C.A., Souza, E.M., Silva, A.X., Cassiano, D.H., Lopes, R.T.: Computed radiography simulation using the Monte Carlo code MCNPX. Appl. Radiat. Isot. 68(9), 1662–1670 (2010). https://doi.org/10.1016/j.apradiso.2010.02.01110.1016/j.apradiso.2010.02.011 ↗
3. Bushberg, J.T., Seibert, J.A., Leidholdt, E.M., Boone, J.M.: The Essential Physics of Medical Imaging, 2nd edn. Lippincott Williams & Wilkins, Philadelphia (2003)
4. Cooper, V.N., Boone, J.M., Seibert, J.A., Pellot-Barakat, C.J.: An edge spread technique for measurement of the scatter-to-primary ratio in mammography. Med. Phys. 27(5), 845–853 (2000). https://doi.org/10.1118/1.59895010.1118/1.598950 ↗
5. Schörner, K., Goldammer, M., Stephan, J.: Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CT. Nucl. Instr. Method B 269(3), 292–299 (2011). https://doi.org/10.1016/j.nimb.2010.11.05310.1016/j.nimb.2010.11.053 ↗
6. Maltz, J.S., Blanz, W.E., Hristov, D., Bani-Hashemi, A.: Cone beam X-ray scatter removal via image frequency modulation and filtering. In: IEEE Engineering in Medicine and Biology, 27th Annual Conference (2006). https://doi.org/10.1109/IEMBS.2005.161681110.1109/IEMBS.2005.1616811 ↗
7. Zhu, L., Bennett, N.R., Fahrig, R.: Scatter correction method for X-ray CT using primary modulation: theory and preliminary results. IEEE Trans. Med. Imaging 25, 1573–1587 (2006). https://doi.org/10.1109/TMI.2006.88463610.1109/TMI.2006.884636 ↗
8. Gao, H., Zhu, L., Fahrig, R.: Modulator design for x-ray scatter correction using primary modulation: material selection. Med. Phys. 37(8), 4029–4037 (2010). https://doi.org/10.1118/1.345747210.1118/1.3457472 ↗
9. Zhu, L., StarLack, J., Bennett, N.R., Li, T., Xing, L., Fahrig, R.: Improved scatter correction for X-ray cone-beam CT using primary modulation. Proc. SPIE. (2007). https://doi.org/10.1117/12.71367810.1117/12.713678 ↗
10. Ritschl, L., Fahrig, R., Knaup, M., Maier, J., Kachelrieß, M.: Robust primary modulation-based scatter estimation for cone-beam CT. Med. Phys. 42(1), 469–478 (2015). https://doi.org/10.1118/1.490326110.1118/1.4903261 ↗
11. Schörner, K., Goldammer, M., Stephan, J.: Scatter correction by modulation of primary radiation in industrial X-ray CT: beam-hardening effects and their correction. In: International Symposium on Digital Industrial Radiology and Computed Tomography (2011)
12. Geng, P., Ten, F., Xiao, D., Kang, Y.: A new X-ray scatter correction method based on BAG for cone-beam CT. In: IEEE International Conference on Information and Automation, Shenyang. (2012). https://doi.org/10.1109/ICInfA.2012.624682710.1109/ICInfA.2012.6246827 ↗
13. Yan, H., Mou, X., Tang, Sh., Chen, X.: Iterative scatter correction for x-ray cone-beam CT with semi-transparent beam stop array. In: Medical Imaging, International Society for Optics and Photonics. (2009). https://doi.org/10.1117/12.81238910.1117/12.812389 ↗
14. Kermani, A., Feghhi, S.A.H.: Scatter signal elimination by localized primary modulation in industrial computed radiography. J. Nondestruct. Eval. 36, 71 (2017)10.1007/s10921-017-0448-y ↗
15. Boone, J.M., Seibert, J.A.: Monte carlo simulation of the scattered radiation distribution in diagnostic radiology. Med. Phys. 15(5), 713–720 (1988). https://doi.org/10.1118/1.59618510.1118/1.596185 ↗
16. Love, L.A., Kruger, R.A.: Scatter estimation for a digital radiographic system using convolution filtering. Med. Phys. 14(2), 178–185 (1987). https://doi.org/10.1118/1.59612610.1118/1.596126 ↗
17. Seibert, J.A., Boone, J.M.: X-ray scatter removal by deconvolution. Med. Phys. 15(4), 567–575 (1988). https://doi.org/10.1118/1.59620810.1118/1.596208 ↗
18. Report of AAPM Task Group 10: Acceptance testing and quality control of photostimulable storage phosphor imaging systems. American Association of Physicists in Medicine (2006)
19. Rokrok, B., Arezabak, B., Khodakarami, M., Kermani, A., Movafeghi, A.: Characteristic curves of phosphorous imaging plates in industrial digital radiography. In: IRNDT International Conference (2016)
20. Rokrok, B., Kermani, A.: Digital radiography image quality assessment of steel step wedge specimen. In: IRNDT International Conference (2016)