journal article·2023-03Open access

Feature-Sensitive Ring Artifact Correction for Computed Tomography

Markus Wedekind, Susana Castillo, Marcus Magnor

Abstract

Abstract In computed tomography (CT) reconstruction, ring artifacts emerge from incorrectly normalized or defective detector elements. Correction algorithms often introduce blur or do not correctly accommodate the behaviour of those artifacts. Normalization errors stem from noise in the detector images during the normalization process and are always present to some degree. We propose a method for correcting ring artifacts from incorrectly normalized detector elements in the sinogram. Our approach compensates for errors both in the individual gain as well as offset of pixel values. We reduce blur by inferring gain and offset information for each pixel from its neighbors only in a subset of all projections. We show with datasets from real measurments that our method is effective at mitigating the shortcomings of purely offset based approaches and approaches using all projections. Furthermore, our method can be efficiently implemented compensating for most overhead times. Under usual circumstances, our method can be implemented to function with no additional time overhead at all.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging · Radiation Dose and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (14)

Show source-provided references
1. Rashid, S., Lee, S.Y., Hasan, M.K.: An improved method for the removal of ring artifacts in high resolution CT imaging. EURASIP J. Adv. Signal Process. 2012(1), 93 (2012)10.1186/1687-6180-2012-93 ↗
2. Hasan, M.K., Sadi, F., Lee, S.Y.: Removal of ring artifacts in micro-CT imaging using iterative morphological filters. SIViP 6(1), 41–53 (2012)10.1007/s11760-010-0170-z ↗
3. Wei, Z., Wiebe, S., Chapman, D.: Ring artifacts removal from synchrotron CT image slices. J. Instrum. 8(06), 06006 (2013)10.1088/1748-0221/8/06/C06006 ↗
4. Münch, B., Trtik, P., Marone, F., Stampanoni, M.: Stripe and ring artifact removal with combined wavelet-fourier filtering. Opt. Express 17(10), 8567–8591 (2009)10.1364/OE.17.008567 ↗
5. Liang, X., Zhang, Z., Niu, T., Yu, S., Wu, S., Li, Z., Zhang, H., Xie, Y.: Iterative image-domain ring artifact removal in cone-beam CT. Phys. Med. Biol. 62(13), 5276 (2017)10.1088/1361-6560/aa7017 ↗
6. Ji, D.-J., Qu, G.-R., Hu, C.-H., Liu, B.-D., Jian, J.-B., Guo, X.-K.: Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts. Chin. Phys. B 26(6), 060701 (2017)10.1088/1674-1056/26/6/060701 ↗
7. Yousuf, M., Asaduzzaman, M.: An efficient ring artifact reduction method based on projection data for micro-CT images. J. Sci. Res. 2(1), 37–45 (2010)10.3329/jsr.v2i1.2645 ↗
8. Anas, E.M.A., Lee, S.Y., Hasan, M.K.: Removal of ring artifacts in CT imaging through detection and correction of stripes in the sinogram. Phys. Med. Biol. 55(22), 6911 (2010)10.1088/0031-9155/55/22/020 ↗
9. Titarenko, V.: 1-D filter for ring artifact suppression. IEEE Signal Process. Lett. 23(6), 800–804 (2016)10.1109/LSP.2016.2554363 ↗
10. Eldib, M.E., Hegazy, M., Mun, Y.J., Cho, M.H., Cho, M.H., Lee, S.Y.: A ring artifact correction method: validation by micro-CT imaging with flat-panel detectors and a 2d photon-counting detector. Sensors 17(2), 269 (2017)10.3390/s17020269 ↗
11. Chang, S., Chen, X., Duan, J., Mou, X.: A cnn based hybrid ring artifact reduction algorithm for CT images. IEEE Trans. Radiat. Plasma Med. Sci. 5, 253 (2020)10.1109/TRPMS.2020.2983391 ↗
12. Yan, L., Wu, T., Zhong, S., Zhang, Q.: A variation-based ring artifact correction method with sparse constraint for flat-detector CT. Phys. Med. Biol. 61(3), 1278 (2016)10.1088/0031-9155/61/3/1278 ↗
13. Alexeev, T., Kavanagh, B., Miften, M., Altunbas, C.: A novel total variation based ring artifact suppression method for cbct imaging with two-dimensional antiscatter grids. Med. Phys. 46(5), 2181–2193 (2019)10.1002/mp.13456 ↗
14. Croton, L.C., Ruben, G., Morgan, K.S., Paganin, D.M., Kitchen, M.J.: Ring artifact suppression in X-ray computed tomography using a simple, pixel-wise response correction. Opt. Express 27(10), 14231–14245 (2019)10.1364/OE.27.014231 ↗