journal article·2011-06

Nondestructive Microstructural Analysis of Porous Bioceramics by Microfocus X-ray Computed Tomography (μCT): A Proposed Protocol for Standardized Evaluation of Porosity and Interconnectivity Between Macro-pores

Hitoshi Nakayama, Douglas M. Burns, Tomoyuki Kawase

Publisher page

Abstract

Microfocus X-ray computed tomography (μCT) has now become widely available for the nondestructive evaluation of porous bioceramics suitable for use as a bone substitute in orthopedic surgery. As part of an official Japanese working committee, we recently participated in the preparation of a proposed standard protocol for the quantitative μCT analysis of porous bioceramics sent to the International Organization for Standardization (ISO). In this protocol, the recommended basic conditions for analysis were [field of view (XY plane): 3.0 mm, spatial resolution: 6 μm/pixel (or the closest minimal values available for both parameters on a particular μCT system), matrix size: 512 pixels], and we have now further determined the optimal values for more detailed parameters (e.g., threshold determination). To validate the utility of the complete protocol, three different types of ceramic sample [a ceramic of β-tricalcium phosphate (β-TCP) and two types of hydroxyapatite (HAp) with different porosities] were evaluated with three different types of cone-beam μCT scanner (the Shimadzu SMX-100CT, Shimadzu inspeXio-90CT, and Skyscan-1174 scanners). Acquired images were quantified using 3D-reconstruction software, VGStudio MAX (version 1.2). After comparing data obtained from these three μCT scanners, we have found that determinations of both porosity and pore-interconnectivity were very similar from one system to the other although the total number of measured pores did vary between scanners. The present data indicate that our protocol for μCT analysis is reliable enough to quantify the porosity and interconnectivity of porous bioceramics and would therefore facilitate both large-scale screening and quality control of porous bioceramic samples.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Advanced X-ray and CT Imaging · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. Sakamoto, M., Nakasu, M., Matzumoto, T., Okihana, H.: Development of superporous hydroxyapatites and their examination with a culture of primary rat osteoblasts. J. Biomed. Mater. Res., Part A 82A, 238–242 (2007)10.1002/jbm.a.31013 ↗
2. Yamamoto, A., Nakajima, T., Tominaga, Y. Ogawa, T.: Porous hydroxyapatite ceramics. Tissue Cell Res. Commun. 18, 235–244 (1999) (in Japanese)
3. Annual report 2008 for “Standardization for Characterization of Bioactive Ceramics” Project, R&D on Standardization Enterprise, the Ministry of Economy, Trade and Industry, Japan (2009) (in Japanese)
4. Nakayama, H., Kawase, T.: Fine structural analysis of bioactive porous ceramics using microcomputed tomography (μCT). Dent. Radiol. 49, 33–40 (2009) (in Japanese)
5. Seibert, J.A.: Flat-panel detectors: how much better are they? Pediatr. Radiol. 36(2), 173–181 (2006)10.1007/s00247-006-0208-0 ↗
6. Bokou, C., Schreiner-Karoussou, A., Breisch, R., Beissel, J.: Changing from image intensifier to flat detector technology for interventional cardiology procedures: a practical point of view. Radiat. Prot. Dosim. 129, 83–86 (2008)10.1093/rpd/ncn151 ↗
7. Spahn, M.: Flat detectors and their clinical applications. Eur. Radiol. 15, 1934–1947 (2005)10.1007/s00330-005-2734-9 ↗
8. Renghini, C., Komlev, V., Fiori, F., Verné, E., Baino, F., Vitale-Brovarone, C.: Micro-CT studies on 3-D bioactive glass-ceramic scaffolds for bone regeneration. Acta Biomater. 5, 1328–1337 (2009)10.1016/j.actbio.2008.10.017 ↗
9. Sprawls, P.: Image characteristics and quality. In: The Physical Principles of Medical Imaging (Online Textbook). http://www.sprawls.org/ppmi2/IMAGCHAR/ (accessed on August 2, 2010)
10. Yamasaki, N., Hirao, M., Nanno, K., Sugiyasu, K., Tamai, N., Hashimoto, N., Yoshikawa, H., Myoui, A.: A comparative assessment of synthetic ceramic bone substitutes with different composition and microstructure in rabbit femoral condyle model. J. Biomed. Mater. Res., Part B, Appl. Biomater. 91, 788–798 (2009)10.1002/jbm.b.31457 ↗
11. Kawase, T., Okuda, K., Kogami, H., Nakayama, H., Nagata, M., Sato, T., Wolff, L.F., Yoshie, H.: Human periosteum-derived cells combined with superporous hydroxyapatite blocks used as an osteogenic bone substitute for periodontal regenerative therapy: Animal implantation study using nude mice. J. Periodontal Res. 81, 420–427 (2010)10.1902/jop.2009.090523 ↗