Abstract

To determine failure locations is a practical effort in many engineering applications. A proper selection of signal wave velocity is critical for the implementation. Current practice in AE using a constant velocity model has a serious disadvantage that may introduce significant error and slow the speed of convergence, and it becomes even worse when the material is in form of complicated structure. In this paper, we proposed a variable velocity model to address this disadvantage. The variable velocity approach is validated by static tests (pencil lead break) and dynamic tests (fatigue tests) performed on a cemented total hip arthroplasty (THA) that has four material layers. Compared to the constant velocity model, the variable velocity approach reduces source location errors in both static (from 7.1 mm to 4.7 mm) and dynamic tests. The results indicated that the proposed variable velocity approach has significant advantages over the constant velocity approach when microcracks occur in a complicated structure.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. Ge, M.: Interpretation of physical status of arrival picks for microseismic source location. Bull. Seismol. Soc. Am. 80, 1643–1660 (1990)10.1785/BSSA08006A1643 ↗
2. Ge, M.: Analysis of AE data from a rocket motor case: key questions in AE source location. In: 40th Meeting of Acoustic Emission Working Group, Chicago, 1997
3. Ge, M.: Analysis of source location algorithms part I: overview and non-iterative methods. J. Acoust. Emis. 21, 14–28 (2004)
4. Ge, M.: Analysis of source location algorithms part II: iterative methods. J. Acoust. Emis. 21, 29–51 (2004)
5. Geiger, L.: Probability method for the determination of earthquake epicenters from the arrival time only. Bull. St. Louis Univ. 8, 60–71 (1912)
6. Li, J.: A 3D acoustic emission based microcrack source localization method and its biomechanical application. Dissertation. The University of Memphis and University of Tennessee Health Science Center, Memphis, TN (2006)
7. Li, J., Qi, G., Mouchon, W.: Noninvasive investigation of early microcrack development in cemented Femur stem models. In: Orthopedic Research Society 52th Annual Meeting, 2006
8. Qi, G., Li, J., Mouchon, W., Lewis, G.: Defect-induced fatigue microcrack formation in cement mantle. J. Biomed. Mater. Res. 75A, 414–424 (2005)10.1002/jbm.a.30446 ↗
9. Qi, G., Li, J., Mann, K., Whitten, A., Hamstad, M., Salehi, A.: 3D real time methodology to monitor cement failure in femoral component of total hip arthroplasty. J. Biomed. Mater. Res. 71A, 391–402 (2004)10.1002/jbm.a.30133 ↗
10. Thurber, C.: Nonlinear earthquake location: theory and examples. Bull. Seismol. Soc. Am. 75, 779–790 (1985)10.1785/BSSA0750030779 ↗