Bolt preload is a critical parameter in bolted connections with a strong influence on their general structural behavior. Traditional bolt preload estimation methods are sensitive to the surface conditions of the fastening elements while more accurate measuring methods might require significant modifications of the connection, such as embedded sensors. In this study, a novel contactless bolt preload monitoring method based on Digital Image Correlation measurements of the bolt elongation was developed. A fixed bolted setup was designed to validate the optical measurements with laser triangulation and three-dimensional point tracking, while the bolt preload was monitored with an embedded load cell. Two M16 bolt classes, 8.8 and 10.9, and multiple bolt lengths were evaluated. The bolt preload and displacement results correlated well with the available bolt theoretical models and an accurate preload estimation was possible. An analysis on the method resolution demonstrates that better resolutions are achieved with slender and long bolts. The method resolution is estimated to be under 2.25% and 1.8% of the recommended bolt preload value for each bolt class, respectively.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Optical measurement and interference techniques · Structural Health Monitoring Techniques · Advanced Measurement and Detection Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Yan, Y., Wen, W.D., Chang, F.K., Shyprykevich, P.: Experimental study on clamping effects on the tensile strength of composite plates with a bolt-filled hole. Compos. A Appl. Sci. Manuf. 30(10), 1215–1229 (1999). https://doi.org/10.1016/S1359-835X(99)00002-010.1016/S1359-835X(99)00002-0 ↗
2. Jiménez-Peña, C., Talemi, R.H., Rossi, B., Debruyne, D.: Investigations on the fretting fatigue failure mechanism of bolted joints in high strength steel subjected to different levels of pre-tension. Tribol. Int. (2017). https://doi.org/10.1016/j.triboint.2016.11.01410.1016/j.triboint.2016.11.014 ↗
3. Benhamena, A., Talha, A., Benseddiq, N., Amrouche, A., Mesmacque, G., Benguediab, M.: Effect of clamping force on fretting fatigue behaviour of bolted assemblies: case of couple steel–aluminium. Mater. Sci. Eng. A 527(23), 6413–6421 (2010). https://doi.org/10.1016/j.msea.2010.06.08010.1016/j.msea.2010.06.080 ↗
4. Esmaeili, F., Chakherlou, T.N., Zehsaz, M.: Investigation of bolt clamping force on the fatigue life of double lap simple bolted and hybrid (bolted/bonded) joints via experimental and numerical analysis. Eng. Fail. Anal. 45, 406–420 (2014). https://doi.org/10.1016/j.engfailanal.2014.07.01410.1016/j.engfailanal.2014.07.014 ↗
5. Esmaeili, F., Chakherlou, T.N., Zehsaz, M., Hasanifard, S.: Investigating the effect of clamping force on the fatigue life of bolted plates using volumetric approach. J. Mech. Sci. Technol. 27(12), 3657–3664 (2013). https://doi.org/10.1007/s12206-013-0911-310.1007/s12206-013-0911-3 ↗
6. Bickford, J.: Handbook of Bolts and Bolted Joints. CRC Press, Boca Raton (1998)10.1201/9781482273786 ↗
7. EN B (2008) 1090-2 (2008): Execution of steel structures and aluminium structures-Part 2: 2. Technical requirements for steel structures. British Standards Institution, London
8. Ueno, T., Yamaji, M., Tsubaki, H., Amasaka, K.: Establishment Of bolt tightening simulation system for automotive industry application of the highly reliable CAE model. Int. Bus. Econ. Res. J. (IBER) (2009). https://doi.org/10.19030/iber.v8i5.313610.19030/iber.v8i5.3136 ↗
9. Nah, H.-S., Lee, H.-J., Kim, K.-S., Kim, J.-H., Kim, W.-B.: Evaluating relaxation of high-strength bolts by parameters on slip faying surfaces of bolted connections. Int. J. Steel Struct. 10(3), 295–303 (2010). https://doi.org/10.1007/bf0321583810.1007/bf03215838 ↗
10. Sedlacek, G., Kammel, C.: Zum Dauerverhalten von GV-Verbindungen in verzinkten Konstruktionen-Erfahrungen mit Vorspannkraftverlusten. Stahlbau 70(12), 917–926 (2001)10.1002/stab.200103120 ↗
11. Mascarenas, D.L., Park, G., Farinholt, K.M., Todd, M.D., Farrar, C.R.: A low-power wireless sensing device for remote inspection of bolted joints. Proc. Inst. Mech. Eng. Part G J. Aerosp. Eng. 223(5), 565–575 (2009)10.1243/09544100JAERO378 ↗
12. Xu, C., Wu, G., Du, F., Zhu, W., Mahdavi, S.H.: A modified time reversal method for guided wave based bolt loosening monitoring in a lap joint. J. Nondestr. Eval. 38(4), 85 (2019). https://doi.org/10.1007/s10921-019-0626-110.1007/s10921-019-0626-1 ↗
13. Yang, J., Chang, F.-K.: Detection of bolt loosening in C-C composite thermal protection panels: I. Diagnostic principle. Smart Mater. Struct. 15(2), 581 (2006)10.1088/0964-1726/15/2/041 ↗
14. Huang, Y., Liu, L., Yeung, T., Hung, Y.: Real-time monitoring of clamping force of a bolted joint by use of automatic digital image correlation. Opt. Laser Technol. 41(4), 408–414 (2009)10.1016/j.optlastec.2008.08.010 ↗
15. Nassar, S.A., Meng, A.: Optical monitoring of bolt tightening using 3D electronic speckle pattern interferometry. J. Pressure Vessel Technol. 129(1), 89–95 (2007)10.1115/1.2389024 ↗
16. Bickford, J.: An Introduction to the Design and Behavior of Bolted Joints, Revised and Expanded, vol. 97. CRC Press, Boca Raton (1995)
17. Koshti, A.M.: Ultrasonic measurement and monitoring of loads in bolts used in structural joints. In: SPIE Smart Structures and Materials+ Nondestructive Evaluation and Health Monitoring, 2015. International Society for Optics and Photonics, pp 94370T-94370T-9431510.1117/12.2083220 ↗
18. Koshti, A.M.: Estimation of accuracy in ultrasonic preload measurements. In: Kundu, T. (ed.) Advanced Nondestructive Evaluation for Structural and Biological Health Monitoring, pp. 300–311. International Society for Optics and Photonics, Bellingham (2001)10.1117/12.434186 ↗
19. Cunningham, B., Holt, A., Johnson, G.: Sensitivity of an ultrasonic technique for axial stress determination. In: Thompson, D.O., Chimenti, D.E. (eds.) Review of Progress in Quantitative Nondestructive Evaluation, pp. 1405–1412. Springer, New York (1988)10.1007/978-1-4613-0979-6_63 ↗
20. Jiménez-Peña, C., Lavatelli, A., Balcaen, R., Rossi, B., Debruyne, D.: Model based bolt preload monitoring using digital image correlation. In: Multidisciplinary Digital Publishing Institute Proceedings, 2018. Vol. 8, p 51410.3390/ICEM18-05413 ↗
21. Bickford, J.: An Introduction to the Design and Behavior of Bolted Joints. Revised and expanded. Routledge, London (2018)
22. Ingeneure, V.D.: VDI 2230: systematic calculation of high duty bolted joints. VDI-Gesellschaft Entwicklung Konstruktion Vertrieb (2003)
23. ISO P (2013) 898-1: 2013. Mechanical properties of fasteners made of carbon steel and alloy steel—Part 1:898-891
24. ASTM International, A.: ASTM F606/F606M-16, Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets. West Conshohocken (2016)
25. Sutton, M.A., Orteu, J.J., Schreier, H.: Image Correlation for Shape, Motion and Deformation Measurements: Basic Concepts, Theory and Applications. Springer, New York (2009)
26. Mazzoleni, P., Zappa, E., Matta, F., Sutton, M.A.: Thermo-mechanical toner transfer for high-quality digital image correlation speckle patterns. Opt. Lasers Eng. 75, 72–80 (2015)10.1016/j.optlaseng.2015.06.009 ↗
27. MatchID software. http://www.matchidmbc.be
28. VIC-3D Software http://correlatedsolutions.com/vic-3d/
29. Bossuyt, S.: Optimized patterns for digital image correlation. In: Jin, H., Sciammarella, C., Furlong, C., Yoshida, S. (eds.) Imaging Methods for Novel Materials and Challenging Applications, vol. 3, pp. 239–248. Springer, New York (2013)10.1007/978-1-4614-4235-6_34 ↗
30. HBM Catalogue: SG/Y series http://www.disensors.com/downloads/products/LY11%20Micro%20Strain%20Gauge_338.pdf
31. ISO E: Fasteners–hexagon head screws–product grades A and B (ISO 4017: 2014) (2014)
32. ISO P 898-1: 2013. Mechanical properties of fasteners made of carbon steel and alloy steel–Part 1:898-891