journal article·2019-06

A Procedure for the Structural Identification of Masonry Towers

Milorad Pavlovic, Sebastiano Trevisani, Antonella Cecchi

Publisher page

Abstract

Historic masonry towers, as well as bell towers, minarets and chimneys, represent an important part of the Mediterranean basin architectural heritage. Widely spread out on the Italian peninsula, the bell towers reflect cultural, social and religious aspects of the communities, thus, their conservation remains an open challenge for scientists, governments and local communities. The seismic behavior of slender masonry structures is, generally, characterized by the combination, of the static vertical loads with dynamic loading. However, the determination of the structural behavior of masonry structures is always a complex challenge due to the material inhomogeneity, manufacturing imperfections, geometric configuration or structural interaction between the layers in the case multi-leaf masonry structures. In this research, an expeditious and low-cost procedure for the structural identification of historic masonry towers is proposed. The procedure, based on experimental measurements and numerical modeling, aims at the estimation of the average mechanical characteristics under service loads. In particular, the procedure proposes the acquisition of the fundamental frequency by means of a single compact digital tromograph and successive finite element model calibration starting from the experimental data. The whole identification procedure has been at first verified on an elementary laboratory specimen, then applied on the historic bell tower of Basilica dei Frari located in the historic city center of Venice.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Health Monitoring Techniques · Masonry and Concrete Structural Analysis · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (52)

Show source-provided references
1. Acito, M., Bocciarelli, M., Chesi, C., Milani, G.: Collapse of the clock tower in Finale Emilia after the May 2012 Emilia Romagna earthquake sequence: numerical insight. Eng. Struct. 72, 70–91 (2014). https://doi.org/10.1016/j.engstruct.2014.04.02610.1016/j.engstruct.2014.04.026 ↗
2. Binda, L., Gatti, G., Mangano, G., Poggi, C., Sacchi Landriani, G.: The collapse of the Civic Tower of Pavia: a survey of the materials and structure. Mason. Int. 6, 11–20 (1992)
3. Cornaro, F.: Notizie storiche delle chiese e monasteri di Venezia, e di Torcello tratte dalle chiese veneziane, e torcellane illustrate da Flaminio Corner. Stamperia del Seminario, Padova (1758)
4. Zanetti, V.: Piccola guida di Murano e delle sue Officine. Naratovich, Venezia (1869)
5. Levi, C.A.: I campanili di Venezia, notizie storiche. Ferdinando Ongaria Editore, Venezia (1890)
6. Antonelli, C., Caselli, C., Arcaini, R.: Relazione sullo stato del Campanile di S. Stefano presentata all’ Ill.o signor sindaco dagli ingegneri architetti Costanzo Antonelli, Crescentino Caselli ed architetto Raineri Arcaini. Officine grafiche Ferrari, Venezia (1902)
7. Donghi, D.: Progetto per la ricostruzione del campanile di San Marco a Venezia. Iuav-Archivio Progetti, Venezia (1902–1912)
8. Beltrami, L.: Resoconto delle indagini e degli studi per la ricostruzione del campanile di San Marco dal marzo al maggio 1903. Tipografia Umberto Allegretti, Milano (1903)
9. Ongaro, M.: Come è caduto il campanile di San Marco. Nutini, Venezia (1904)
10. Fradeletto, A.: Il campanile di San Marco riedificato: studi, ricerche, relazioni. Carlo Ferrari, Venezia (1912)
11. Lionello, A.: Tecniche costruttive, dissesti e consolidamenti dei campanili di Venezia. Ministero per i beni e le attività culturali, Soprintendenza per i beni architettonici e paesaggistici di Venezia e Laguna, Corbo e Fiore, Venezia (2011)
12. Modena, C., Valluzzi, M.R., Tongini Folli, R., Binda, L.: Design choices and intervention techniques for repairing and strengthening of the Monza cathedral bell-tower. Constr. Build. Mater. 16, 385–395 (2002). https://doi.org/10.1016/S0950-0618(02)00041-710.1016/S0950-0618(02)00041-7 ↗
13. Carpinteri, A., Invernizzi, S., Lacidogna, G.: In situ damage assessment and non linear modelling of a historical masonry tower. Eng. Struct. 27, 387–395 (2005). https://doi.org/10.1016/j.engstruct.2004.11.00110.1016/j.engstruct.2004.11.001 ↗
14. Barsotti, R., Bennati, S., Nardini, L., Salvatore, W.: Characterisation of the mechanical behaviour of the bell tower of the cathedral of San Miniato (Pisa). WIT Trans. Built Environ. 98, 343–355 (2008). https://doi.org/10.2495/SU08034110.2495/SU080341 ↗
15. Anzani, A., Binda, L., Carpinteri, A., Invernizzi, S., Lacidogna, G.: A multilevel approach for the damage assessment of Historic masonry towers. J. Cult. Herit. 11, 459–470 (2010). https://doi.org/10.1016/j.culher.2009.11.00810.1016/j.culher.2009.11.008 ↗
16. Lorenzoni, F., Valluzzi, M.R., Modena, C., Simonato, E., Casarin, F., Lionello, A.: Settlement induced damage modelling of historical buildings: the Bell tower of the “Basilica dei Frari” in Venice. Adv. Mater. Res. 133–134, 561–566 (2010). https://doi.org/10.4028/www.scientific.net/AMR.133-134.56110.4028/www.scientific.net/AMR.133-134.561 ↗
17. Foti, D., Diaferio, M., Giannocaro, N.I., Mongelli, M.: Ambient vibration testing, dynamic identification and model updating of a historic tower. NDT&E Int. 47, 88–95 (2012). https://doi.org/10.1016/j.ndteint.2011.11.00910.1016/j.ndteint.2011.11.009 ↗
18. Ewins, D.J.: Modal Testing: Theory, Practice and Application. Research Studies Press LTD, Letchworth (1984)
19. Delli Carri, A., Weekes, B., Di Maio, D., Ewins, D.J.: Extending modal testing technology for model validation of engineering structures with sparse nonlinearities: a first case study. Mech. Syst. Signal Process. 84, 97–115 (2017). https://doi.org/10.1016/j.ymssp.2016.04.01210.1016/j.ymssp.2016.04.012 ↗
20. Papadopoulos, M., Beeumen, R.V., François, S., Degrande, G., Lombaert, G.: Modal characteristics of structures considering dynamic soil-structure interaction effects. Soil Dyn. Earthq. Eng. 105, 114–118 (2018). https://doi.org/10.1016/j.soildyn.2017.11.01210.1016/j.soildyn.2017.11.012 ↗
21. Gentile, C., Saisi, A.: Ambient vibration testing of historic masonry towers for structural identification and damage assessment. Constr. Build. Mater. 21, 1311–1321 (2007). https://doi.org/10.1016/j.conbuildmat.2006.01.00710.1016/j.conbuildmat.2006.01.007 ↗
22. Teza, G., Pesci, A., Trevisani, S.: Multisensor surveys of tall historical buildings in high seismic hazard areas before and during a seismic sequence. J. Cult. Herit. 16(3), 255–266 (2015). https://doi.org/10.1016/j.culher.2014.06.00810.1016/j.culher.2014.06.008 ↗
23. Jacobsen, N.J., Thourhage, O.: Data acquisition systems for Operational Modal Analysis. In: Proceedings of the 3rd IOMAC, 4–6 May 2009, Porto Novo, Italy, pp. 215–222 (2009)
24. Masjedian, M.H., Keshmiri, M.: A review on Operational Modal Analysis researches: classification of methods and applications. In: Proceedings of the 3rd IOMAC, 4–6 May 2009, Porto Novo, Italy, 677–686 (2009)
25. Foti, D.: Non-destructive techniques and monitoring for the evolutive damage detection of an ancient masonry structure. Key Eng. Mater. 628, 168–177 (2015). https://doi.org/10.4028/www.scientific.net/KEM.628.16810.4028/www.scientific.net/KEM.628.168 ↗
26. Diaferio, D., Foti, D., Gentile, C., Giannoccaro, N.I., Saisi, A.: Dynamic testing of a historical slender building using accelerometers and radar. In: Proceedings of the 6th IOMAC, 12–14 May 2015, Giyon, Spain, pp. 129–130 (2015)
27. Foti, D., Diaferio, M., Giannoccaro, N.I., Ivorra, S.: Structural Identification and numerical models for slender historic structures. In: Asteris, P., Plevris, V. (eds.) Handbook of Research on Seismic Assessment and Rehabilitation of Historic Structures. Engineering Science Reference, pp. 674–703. (2015). https://doi.org/10.4018/978-1-4666-8286-3.ch02310.4018/978-1-4666-8286-3.ch023 ↗
28. David-West, O.S., Wang, J., Cooper, R.: Finite element model updating of a thin wall enclosure under impact excitation. Appl. Mech. Mater. 24(25), 337–342 (2010). https://doi.org/10.4028/www.scientific.net/AMM.24-25.33710.4028/www.scientific.net/AMM.24-25.337 ↗
29. Diaferio, M., Foti, D., Giannoccaro, N.I., Ivorra, S.: Optimal model through identified frequencies of a masonry building structure with wooden floors. Int. J. Mech. 8(1), 282–288 (2014)
30. Mottershead, J.E., Friswell, M.I.: Model updating in structural dynamics: a survey. J. Sound Vib. 22(2), 347–375 (1993). https://doi.org/10.1006/jsvi.1993.134010.1006/jsvi.1993.1340 ↗
31. Mares, C., Mottershead, J.E., Friswell, M.I.: Results obtained by minimising natural-frequency errors and using physical reasoning. Mech. Syst. Signal Process. 17(1), 39–46 (2003). https://doi.org/10.1006/mssp.2002.153710.1006/mssp.2002.1537 ↗
32. Nalitolela, N.G., Penny, J.E.T., Friswell, M.I.: A mass or stiffness addition technique for structural parameter updating. Int. J. Anal. Exp. Modal Anal. 7(3), 157–168 (1992)
33. Reh, S., Beley, J.D., Mukherjee, S., Khor, E.H.: Probabilistic finite element analysis using ANSYS. Struct. Saf. 28, 17–43 (2006). https://doi.org/10.1016/j.strusafe.2005.03.01010.1016/j.strusafe.2005.03.010 ↗
34. Zapico, J.L., Gonzalez, M.P., Friswell, M.I., Taylor, C.A., Crewe, A.J.: Finite element model updating of a small scale bridge. J. Sound Vib. 268(5), 993–1012 (2003). https://doi.org/10.1016/S0022-460X(03)00409-710.1016/S0022-460X(03)00409-7 ↗
35. Bayraktar, A., Türker, T., Sevim, B., Altunişik, A.C., Yildirim, F.: Modal parameter identification of Hagia Sophia bell-tower via ambient vibration test. J. Nondestr. Eval. 28, 37–47 (2009). https://doi.org/10.1007/s10921-009-0045-910.1007/s10921-009-0045-9 ↗
36. Diaferio, M., Foti, D., Potenza, F.: Prediction of the fundamental frequencies and modal shapes of historic masonry towers by empirical equations based on experimental data. Eng. Struct. 156, 433–442 (2018)10.1016/j.engstruct.2017.11.061 ↗
37. Bonnefoy-Claudet, S., Cotton, F., Bard, P.: The nature of noise wavefield and its applications for site effects studies. A literature review. Earth-Sci. Rev. 79(3–4), 205–227 (2006)10.1016/j.earscirev.2006.07.004 ↗
38. Tromino, http://moho.world/en/tromino/ , Accessed 21 March, 2018
39. Trevisani, S., Boaga, J., Agostini, L., Galgaro, A.: Insights into bedrock surface morphology using low-cost passive seismic surveys and integrated geostatistical analysis. Sci. Total Environ. 578, 186–202 (2017). https://doi.org/10.1016/j.scitotenv.2016.11.04110.1016/j.scitotenv.2016.11.041 ↗
40. Boaga, J., Renzi, S., Deiana, R., Cassiani, G.: Soil damping influence on seismic ground response: a parametric analysis for weak to moderate ground motion. Soil Dyn. Earthq. Eng. 79, 71–79 (2015). https://doi.org/10.1016/j.soildyn.2015.09.00210.1016/j.soildyn.2015.09.002 ↗
41. D’Amico, V., Picozzi, M., Baliva, F., Albarello, D.: Ambient noise measurements for preliminary site-effects characterization in the Urban area of Florence, Italy. Bull. Seismol. Soc. Am. 98(3), 1373–1388 (2008). https://doi.org/10.1785/012007023110.1785/0120070231 ↗
42. Seht, M.I., Wohlenberg, J.: Microtremor measurements used to map thickness of soft sediments. Bull. Seismol. Soc. Am. 89(1), 250–259 (1999)10.1785/BSSA0890010250 ↗
43. Mucciarelli, M.: Ambient noise measurements on soil and buildings. Bull. Earthq. Eng. 8(3), 481–482 (2010). https://doi.org/10.1007/s10518-010-9179-510.1007/s10518-010-9179-5 ↗
44. Masi, A., Vona, M.: Experimental and numerical evaluation of the fundamental period of undamaged and damaged RC framed buildings. Bull. Earthq. Eng. 8(3), 643–656 (2009). https://doi.org/10.1007/s10518-009-9136-310.1007/s10518-009-9136-3 ↗
45. Massa, M., Marzorati, S., Ladina, C., Lovati, S.: Urban seismic stations: soil–structure interaction assessment by spectral ratio analyses. Bull. Earthq. Eng. 8(3), 723–738 (2009). https://doi.org/10.1007/s10518-009-9138-110.1007/s10518-009-9138-1 ↗
46. Castellaro, S., Perricone, L., Bartolomei, M., Isani, S.: Dynamic characterization of the Eiffel tower. Eng. Struct. 126, 628–640 (2016). https://doi.org/10.1016/j.engstruct.2016.08.02310.1016/j.engstruct.2016.08.023 ↗
47. Aldreghetti, I., Baraldi, D., Boscato, G., Cecchi, A., Massaria, L., Pavlovic, M., Reccia, E., Tofani, I.: Multi-leaf masonry walls with full, damaged and consolidated infill: experimental and numerical analyses. Key Eng. Mater. 747, 488–495 (2017). https://doi.org/10.4028/www.scientific.net/KEM.747.48810.4028/www.scientific.net/KEM.747.488 ↗
48. Gottardi, G., Lionello, A., Marchi, M., Rossi, P.P.: Monitoring-driven design of a multiphase intervention for the preservation of the Frari bell tower in Venice. Riv. Italiana Geotec. 49(1), 45–64 (2015)
49. Lorenzoni, F., Valluzzi, M.R., Modena, C., Simonato, E., Casarin, F., Lionello, A.: Settlement induced damage modelling of historical buildings: the bell tower of the “Basilica dei Frari” in Venice. Adv. Mater. Res. 133(134), 561–566 (2010). https://doi.org/10.4028/www.scientific.net/AMR.133-134.56110.4028/www.scientific.net/AMR.133-134.561 ↗
50. Lionello, A., Cavaggioni, I., Rossi, P.P., Rossi, C., Modena, C., Casarin, F., Marchi, G., Gottardi, G., Ragazzini, A.: Preliminary investigation and monitoring for the design of a strengthening intervention of the Frari basilica in Venice. SAHC 2004 Structural Analysis of Historic Constructions, Possibilities of Numerical and Experimental Techniques. Proceedings of the fourth International Seminar on Structural Analysis of Historical Structures, 10–13 November 2004, Padova, Italy, pp. 1323–1333 (2005)
51. Pavlovic, M., Baraldi, D., Reccia, E., Tralli, A.: Modal analysis of Frari historical bell tower in Venice: A comparison between detailed and simplified models. CIVIL-COMP 2015, The Fifteenth International Conference on Civil, Structural and Environmental Engineering Computing, at Prague (Czech Republic) In: Proceedings of the fifteenth international conference on civil, structural and environmental engineering computing, vol. 108, pp. 1–19 (2015) https://doi.org/10.4203/ccp.108.5210.4203/ccp.108.52 ↗
52. Pavlovic, M., Trevisani, S., Cecchi, A.: Experimental and numerical analysis of a historical bell tower. In: ICACCE 2016: 18th International Conference on Architectural, Civil and Construction Engineering, December 19–20, Istanbul, Turkey. World Academy of Science, Engineering and Technology. Int. J. Civil Environ. Struct. Constr. Archit. Eng. 10(12), 1500–1507. (2016) http://waset.org/publications/10005836