Abstract

Pulsed eddy current testing of wall-thinning through cladding and insulation was studied from both theoretical and experimental aspects. The analytical solution was derived for a simplified four-layered structure and was used to conduct simulations to ascertain the feasibility of this method. A pulsed eddy current testing probe consisting of a circular excitation coil and an AMR-sensor-embedded differential detector was fabricated to measure the time-varying magnetic field signals on the axisymmetric excitation coil’s axis. The measurement system was able to measure magnetic field down to a few hundred micro-Gausses in an unshielded environment. Simulation and test results showed that over a certain time after turning off the excitation current the magnetic field signal’s decay behavior is almost merely relevant to the pipe’s wall thickness. Future development of a carbon steel pipe’s wall-thinning can be evaluated by using decay coefficients estimated from previously obtained test data.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Non-Destructive Testing Techniques · Ultrasonics and Acoustic Wave Propagation · Welding Techniques and Residual Stresses

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Smith, R.A., Hugo, G.R.: Transient eddy current NDE for ageing aircraft—capabilities and limitations. Insight 43, 14–20 (2001)
2. Harrison, D.J.: Transient eddy currents-are they here to stay? Insight 47(3), 144–152 (2005)10.1784/insi.47.3.144.61310 ↗
3. Tai, C., Rose, J.H., Moulder, J.C.: Thickness and conductivity of metallic layers from pulsed eddy-current measurements. Rev. Sci. Instrum. 67(11), 3965–3972 (1996)10.1063/1.1147300 ↗
4. Bowler, J.: Prediction and analysis of transient eddy-current probe signal. Rev. Progr. Quant. Nondestruct. Eval. 9, 287–293 (1990)10.1007/978-1-4684-5772-8_35 ↗
5. Bowler, J., Johnson, M.: Pulsed eddy-current response to a conducting half-space. IEEE Trans. Magn. 33(3), 2258–2264 (1997)10.1109/20.573841 ↗
6. De Hann, V.O., De Jong, P.A.: Analytical expression for transient induction voltage in a receiving coil due to coaxial transmitting coil over a conducting plate. IEEE Trans. Magn. 40(2), 371–378 (2004)10.1109/TMAG.2004.824100 ↗
7. Ludwig, R., Dai, X.: Numerical and analytical modeling of pulsed eddy current currents in a conducting half-space. IEEE Trans. Magn. 26(1), 299–307 (1990)10.1109/20.50558 ↗
8. Burke, S.K.: Eddy current inspection of cracks in a multilayer conductor. J. Appl. Phys. 67(1), 465–476 (1990)10.1063/1.345227 ↗
9. Burke, S.K., Hugo, G.R., Harrison, D.J.: Transient eddy-current NDE for hidden corrosion in multilayer structure. Rev. Progr. Quant. Nondestruct. Eval. 17, 307–314 (1998)10.1007/978-1-4615-5339-7_39 ↗
10. Burke, S.K., Hugo, G.R., Moulder, J.C.: Short-time behavior in pulsed eddy-current nondestructive evaluation. Rev. Progr. Quant. Nondestruct. Eval. 18, 485–492 (1999)10.1007/978-1-4615-4791-4_61 ↗
11. Dolabdjian, C.P., Perez, L., De Hann, V.O., De Jong, P.A.: Performance of magnetic pulsed-eddy-current system using high dynamic and high linearity improved giant magneto resistance magnetometer. IEEE Sens. J. 6(6), 1511–1517 (2006)10.1109/JSEN.2006.883095 ↗
12. Cohn, M.J., Norton, J.W.: Case studies of pulsed eddy current to measure wall loss in feed water piping and heater shells. In: Proceeding of PVP2008 ASME Pressure Vessels and Piping Division Conference (2008)
13. Robers, M.A., Scottini, R.: Pulsed eddy current in corrosion detection. NDT.net 7(10) (2002). http://www.ndt.net/article/ecndt02/251/251.htm . Accessed on Sep. 12, 2011
14. Fan, M., Huang, P., et al.: Analytical modeling for transient probe response in pulsed eddy current testing. NDT E Int. 42(5), 376–383 (2009)10.1016/j.ndteint.2009.01.005 ↗
15. Cheng, W., Komura, I.: Simulation for the assessment of wall-thinning using eddy current method. In: Proc. 7th Annual Conference of Japanese Society of Maintenology, pp. 308–313 (2010)
16. Cheng, W., Komura, I.: Simulation for the assessment of wall-thinning using eddy current method. Rev. Progr. Quant. Nondestruct. Eval. 30, 372–379 (2010)
17. Gibb’s phenomenon: http://en.wikipedia.org/wiki/Gibbs_phenomenon . Accessed on Sep. 12, 2011
18. Honeywell: 1- and 2-Axis Magnetic Sensors. http://www51.honeywell.com/aero/common/documents/myaerospacecatalog-documents/Missiles-Munitions/HMC_1001-1002-1021-1022_Data_Sheet.pdf . Accessed on Sep. 12, 2011
19. Angain, C.S., Park, D.G., Kim, C.G., Leela, P., Kollu, P., Cheong, Y.M.: The pulsed eddy current differential probe to detect variation in an insulated stainless steel. J. Nondestruct. Eval. 29(4), 248–252 (2010)10.1007/s10921-010-0083-3 ↗