journal article·2020-09

Porous titanium substrates coated with a bilayer of bioactive glasses

Ana M. Beltrán, Ana Alcudia, Belén Begines, José A. Rodríguez-Ortiz, Yadir Torres

Publisher page

Abstract

Porous titanium substrates coated by dripping-sedimentation technique with a novel bilayer of (45S5 / 1393) bioactive glasses are proposed to overcome some limitations of the use of titanium for implants, such as the stress shielding and the poor osseointegration. Composition, thickness, roughness and micromechanical behavior (P-h curves) of the coating and the influence of the porous titanium substrates have been characterized. Best results were found for the substrate with 30 vol.% of porosity and a range size of 355 ‒ 500 μm, since it enhanced the mechanical and biofunctional behavior, due to the good adhesion of the 1393 bioglass to the substrate and the greater bioactivity of the 45S5 bioglass, which would be in contact with the bone.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. I.R. Dental Implants Market Size & Growth, Dental Implants Market Size, Share & Trends Analysis Report By Product (Titanium Implants, Zirconium Implants), By Region (North America, Europe, Asia Pacific, Latin America, MEA), And Segment Forecasts, 2018–2024, 2018. https://doi.org/10.18637/jss.v042.i08.10.18637/jss.v042.i08 ↗
2. Risk factors associated with early failure of dental implants. A literature review
3. Removal of failed dental implants revisited: questions and answers10.1002/cre2.234 ↗
4. Factors influencing the failure of dental implants: a systematic review
5. Current state-of-the-art and future perspectives of the three main modern implant-dentistry concerns: aesthetic requirements, mechanical properties, and peri-implantitis prevention10.1002/jbm.a.36661 ↗
6. Balancing biofunctional and biomechanical properties using porous titanium reinforced by carbon nanotubes10.1002/jbm.a.36586 ↗
7. Porous titanium cylinders obtained by the freeze- casting technique: influence of process parameters on porosity and mechanical behavior
8. Methods to improve osseointegration of dental implants in low quality (type-IV) bone: an overview
9. Titanium surface modified by hydroxyapatite coating for dental implants10.1016/j.surfcoat.2012.03.037 ↗
10. Processing and properties of hydroxyapatite-based biomaterials for use as hard tissue replacement implants10.1557/JMR.1998.0015 ↗
11. Bone bonding behavior of the hydroxyapatite containing glass-titanium composite prepared by the Cullet method10.1016/S0142-9612(00)00402-6 ↗
12. A comprehensive review of hydroxyapatite-based coatings adhesion on metallic biomaterials10.1016/j.ceramint.2017.10.162 ↗
13. Hydroxyapatite coatings in prosthetic joints10.1016/S1888-4415(08)74805-7 ↗
14. Nanoscale hydroxyapatite particles for bone tissue engineering10.1016/j.actbio.2011.03.019 ↗
15. Nasar · 2018
16. Reprint of: review of bioactive glass: from Hench to hybrids10.1016/j.actbio.2015.07.019 ↗
17. Effect of crystallization on apatite-layer formation of bioactive glass 45S510.1002/(SICI)1097-4636(199604)30:4<509::AID-JBM9>3.0.CO;2-T ↗
18. 45S5 Bioglass®-derived glass-ceramic scaffolds for bone tissue engineering10.1016/j.biomaterials.2005.11.025 ↗
19. Preparation and characterization of mechanical properties of carbon nanotube/45S5Bioglass composites for biologic applications10.1016/j.msea.2010.10.077 ↗
20. Porous and strong bioactive glass (13-93) scaffolds prepared by unidirectional freezing of camphene-based suspensions10.1016/j.actbio.2011.07.034 ↗
21. Bioactive glasses: where are we and where are we going?10.3390/jfb9010025 ↗
22. Coefficient of thermal expansion of bioactive glasses: available literature data and analytical equation estimates10.1016/j.ceramint.2011.05.048 ↗
23. Studies on effect of CuO addition on mechanical properties and in vitro cytocompatibility in 1393 bioactive glass scaffold10.1016/j.msec.2018.08.003 ↗
24. Bioactive glass in tissue engineering10.1016/j.actbio.2011.03.016 ↗
25. Processing, characterization and biological testing of porous titanium obtained by space-holder technique10.1007/s10853-012-6586-9 ↗
26. Development of porous titanium for biomedical applications: a comparison between loose sintering and space-holder techniques10.1016/j.msec.2013.11.036 ↗
27. On the influence of space holder in the development of porous titanium implants: mechanical, computational and biological evaluation10.1016/j.matchar.2015.08.019 ↗
28. Porous titanium for biomedical applications: evaluation of the conventional powder metallurgy frontier and space-holder technique
29. Designing, processing and characterisation of titanium cylinders with graded porosity: an alternative to stress-shielding solutions10.1016/j.matdes.2014.06.012 ↗
30. Bioactive glass coatings: a review10.1179/1743294410Y.0000000008 ↗
31. Induction of VEGF secretion from bone marrow stromal cell line (ST-2) by the dissolution products of mesoporous silica glass particles containing CuO and SrO10.1016/j.jnoncrysol.2018.07.073 ↗
32. Structural characterization of bioactive glasses by solid state NMR10.1007/s10971-018-4795-7 ↗