A new DTA method for measuring critical cooling rate for glass formation
Source abstract
Abstract
A new differential thermal analysis (DTA) experimental method has been developed to determine the critical cooling rate for glass formation, R(sub c). The method, which is found especially suitable for melts that, upon cooling, have a small heat of crystallization or a very slow crystallization rate, has been verified using a 38Na2O-62SiO2 (mol%) melt with a known R(sub c) (-approx. 19 C/min), then used to determine R(sub c) for two complex lithium silicate glass forming melts. The new method is rapid, easy to conduct and yields values for R(sub c) that are in excellent agreement with the R(sub c)-values measured by standard DTA techniques.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Glass properties and applications · Thermal and Kinetic Analysis · Pigment Synthesis and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Glass science and technology
2. Materials science and technology
3. Barandiaran · J. Non-Cryst. Solids · 1981 · 46 · 27710.1016/0022-3093(81)90006-5 ↗
4. Whichard · J. Non-Cryst. Solids · 1984 · 66 · 47710.1016/0022-3093(84)90371-5 ↗
5. Huang · J. Non-Cryst. Solids · 1986 · 86 · 20410.1016/0022-3093(86)90488-6 ↗
6. Schroers · Appl. Phys. Lett. · 2002 · 80 · 206910.1063/1.1462861 ↗
7. Havermans · J. Non-Cryst. Solids · 1970 · 5 · 6610.1016/0022-3093(70)90197-3 ↗
8. EasyPlot Software IITM, version 2.20, Spiral Software, Brooklin, MA, 1992