journal article·2020-07

RETRACTED ARTICLE: KRLODPLSMR-GCV3DC—improving contrast-based photoacoustic imaging based on model reconstruction

Weixin Kang, Haoxiang Gao, Dawei Pan, Xuandi Zhao

Journal of Nanoparticle Research· Volume 22· Issue 7
This record is marked as retracted by the source. Review the publisher’s notice before using its findings.
Publisher page

Abstract

Contrast-based photoacoustic imaging is an emerging imaging technology that gold nanoparticles (a kind of photoacoustic contrast agent with a size of 100 nm) are injected into blood vessels for photoacoustic imaging. Image reconstruction is a critical step in photoacoustic imaging, due to the fact that limitations and incompleteness of photoacoustic imaging data of image reconstruction are equivalent to the linear inverse problems. The photoacoustic data is transferred to IOT based on the platform of MATLAB and is quickly processed through the regularization method of Krylov space (the widely used method is LSQR). In order to solve the problem of Krylov space uncertainty, Krylov space dimension selection, and the minimum mismatch of the LSQR objective function (the limitation of LSQR algorithm) of LSQR algorithm, a KRLODPLSMR-GCV3DC algorithm is proposed to solve the above problems in this paper.In this study, the raw photoacoustic data was obtained by injecting gold nanoparticles into capillaries and subcutaneous veins of the palm, and the KRLODPLSMR-GCV3DC algorithm was verified to solve the limitations of LSQR algorithm through four groups of experiments.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Thermography and Photoacoustic Techniques · Optical Imaging and Spectroscopy Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Agarwal A, Huang S, O’donnell M, Day K, Day M, Kotov N, Ashkenazi S (2007) Targeted gold nanorod contrast agent for prostate cancer detection by photoacoustic imaging. J Appl Phys 102(6):06470110.1063/1.2777127 ↗
2. Beard P (2011) Biomedical photoacoustic imaging. Interface Focus 1(4):602–63110.1098/rsfs.2011.0028 ↗
3. Bhatt M, Acharya A, Yalavarthy PK (2016a) Computationally efficient error estimate for evaluation of regularization in photoacoustic tomography. J Biomed Opt 21(10):10600210.1117/1.JBO.21.10.106002 ↗
4. Bhatt M, Gutta S, Yalavarthy PK (2016b) Exponential filtering of singular values improves photoacoustic image reconstruction. JOSA A 33(9):1785–179210.1364/JOSAA.33.001785 ↗
5. Boley DL (1994) Krylov space methods on state-space control models. Circ Syst Signal Process 13(6):733–75810.1007/BF02523124 ↗
6. Bu S, Liu Z, Shiina T, Kondo K, Yamakawa M, Fukutani K, Someda Y, Asao Y (2012) Model-based reconstruction integrated with fluence compensation for photoacoustic tomography. IEEE Trans Biomed Eng 59(5):1354–136310.1109/TBME.2012.2187649 ↗
7. Busse G, Rosencwaig A (1980) Subsurface imaging with photoacoustics. Appl Phys Lett 36(10):815–81610.1063/1.91327 ↗
8. Chung J, Nagy JG, O’Leary DP (2008) A weighted GCV method for Lanczos hybrid regularization. Electronic Transactions on Numerical Analysis 28 (Electronic Transactions on Numerical Analysis)
9. Copland JA, Eghtedari M, Popov VL, Kotov N, Mamedova N, Motamedi M, Oraevsky AA (2004) Bioconjugated gold nanoparticles as a molecular based contrast agent: implications for imaging of deep tumors using optoacoustic tomography. Mol Imaging Biol 6(5):341–34910.1016/j.mibio.2004.06.002 ↗
10. Cox B, Tarvainen T, Arridge S (2011) Multiple illumination quantitative photoacoustic tomography using transport and diffusion models. In: Bal G, Finch D, Kuchment P, Schotland J, Stefanov P, Uhlmann G (eds) Tomography and inverse transport theory, vol 559, pp 1–1210.1090/conm/559/11067 ↗
11. Engl HW, Grever W (1994) Using the l–curve for determining optimal regularization parameters. Numer Math 69(1):25–3110.1007/s002110050078 ↗
12. Golub G, Kahan W (1965) Calculating the singular values and pseudo-inverse of a matrix. J Soc Ind Appl Math Series B Numer Anal 2(2):205–22410.1137/0702016 ↗
13. Golub G, Von Matt U (1997) Generalized cross-validation for large-scale problems. J Comput Graph Stat 6(1):1–3410.1080/10618600.1997.10474725 ↗
14. Golub G, Hansen PC, O’Leary DP (1999) Tikhonov regularization and total least squares. SIAM J Matrix Anal Appl 21(1):185–19410.1137/S0895479897326432 ↗
15. Gutta S, Kalva SK, Pramanik M, Yalavarthy PK (2018) Accelerated image reconstruction using extrapolated tikhonov filtering for photoacoustic tomography. Med Phys 45(8):3749–376710.1002/mp.13023 ↗
16. Hannukainen A, Hyvonen N, Majander H, Tarvainen T (2016) Efficient inclusion of total variation type priors in quantitative photoacoustic tomography. SIAM J Imaging Sci 9(3):1132–115310.1137/15M1051737 ↗
17. Hansen PC, O’Leary DP (1993) The use of the l-curve in the regularization of discrete ill-posed problems. SIAM J Sci Comput 14(6):1487–150310.1137/0914086 ↗
18. Hansen PC, Nagy JG, O’leary DP (2006) Deblurring images: matrices, spectra, and filtering, vol 3. Siam10.1137/1.9780898718874 ↗
19. Hansen PC (2007a) Regularization tools version 4.0 for matlab 7.3. Numer Algorithm 46(2):189–19410.1007/s11075-007-9136-9 ↗
20. Hansen PC, Kilmer ME (2007b) A parameter-choice method that exploits residual information. In: PAMM: Proceedings in Applied Mathematics and Mechanics, vol 7. Wiley Online Library, pp 1021705–102170610.1002/pamm.200700264 ↗
21. Hodgson R (1994) Regularization techniques applied to depth profiling with photoacoustic spectroscopy. J Appl Phys 76(11):7524–752910.1063/1.357983 ↗
22. Hristova Y, Kuchment P, Nguyen L (2008) Reconstruction and time reversal in thermoacoustic tomography in acoustically homogeneous and inhomogeneous media. Inverse Probl 24(5):05500610.1088/0266-5611/24/5/055006 ↗
23. Jose J, Willemink RG, Steenbergen W, Slump CH, van Leeuwen TG, Manohar S (2012) Speed-of-sound compensated photoacoustic tomography for accurate imaging. Med Phys 39 (12):7262–727110.1118/1.4764911 ↗
24. Kirchner M, Gloe T (2009) On resampling detection in re-compressed images. In: 2009 First IEEE International Workshop on Information Forensics and Security (WIFS). IEEE, pp 21–2510.1109/WIFS.2009.5386489 ↗
25. Ku G, Wang X, Stoica G, Wang L (2004) Multiple-bandwidth photoacoustic tomography. Phys MeSSSiol 49(7):1329
26. Kuntz J, Flach B, Kueres R, Semmler W, Kachelrieß M, Bartling S (2013) Constrained reconstructions for 4d intervention guidance. Phys Med Biol 58(10):328310.1088/0031-9155/58/10/3283 ↗
27. Lee C, Kim J, Zhang Y, Jeon M, Liu C, Song L, Lovell JF, Kim C (2015) Dual-color photoacoustic lymph node imaging using nanoformulated naphthalocyanines. Biomaterials 73:142–14810.1016/j.biomaterials.2015.09.023 ↗
28. Liu W, Wang L, Li L, Liu J, Liu FQ, Wang Z (2011) Fast simultaneous measurement of multi-gases using quantum cascade laser photoacoustic spectroscopy. Appl Phys B 103 (3):743–74710.1007/s00340-010-4298-x ↗
29. Lorent A, Cierniak R (2014) Regularized image reconstruction from projections method. In: 2014 International Conference on Engineering and Telecommunication. IEEE, pp 82–8610.1109/EnT.2014.28 ↗
30. Mojabi P, LoVetri J (2008) Adapting the normalized cumulative periodogram parameter-choice method to the Tikhonov regularization of 2-d/tm electromagnetic inverse scattering using born iterative method. Progress Electromagnet Res 1:111–13810.2528/PIERM08012401 ↗
31. Nguyen N, Milanfar P, Golub G (2001) A computationally efficient superresolution image reconstruction algorithm. IEEE Trans Image Process 10(4):573–58310.1109/83.913592 ↗
32. Okawa S, Hirasawa T, Kushibiki T, Ishihara M (2015) Image reconstruction of the absorption coefficients with l1-norm minimization from photoacoustic measurements. Quant Imaging Med Surgery 5(1):78
33. Prakash J, Raju AS, Shaw CB, Pramanik M, Yalavarthy PK (2014) Basis pursuit deconvolution for improving model-based reconstructed images in photoacoustic tomography. Biomed Opt Express 5(5):1363–137710.1364/BOE.5.001363 ↗
34. Roitner H, Haltmeier M, Nuster R, O’Leary DP, Berer T, Paltauf G, Grün H, Burgholzer P (2014) Deblurring algorithms accounting for the finite detector size in photoacoustic tomography. J Biomed Opt 19(5):05601110.1117/1.JBO.19.5.056011 ↗
35. Scherzer O (1993) The use of Morozov’s discrepancy principle for tikhonov regularization for solving nonlinear ill-posed problems. Computing 51(1):45–6010.1007/BF02243828 ↗
36. Sguarizi-Antonio D, Torres VO, Firmino EL, Lima SM, Andrade LH, Antonialli-Junior WF (2017) Observation of intra-and interspecific differences in the nest chemical profiles of social wasps (hymenoptera: Polistinae) using infrared photoacoustic spectroscopy. J Photochem Photobiol B: Biol 176:165–17010.1016/j.jphotobiol.2017.10.001 ↗
37. Shaw CB, Prakash J, Pramanik M, Yalavarthy PK (2013) Least squares QR-based decomposition provides an efficient way of computing optimal regularization parameter in photoacoustic tomography. J Biomed Opt 18(8):08050110.1117/1.JBO.18.8.080501 ↗
38. Song X, Pogue BW, Jiang S, Doyley MM, Dehghani H, Tosteson TD, Paulsen KD (2004) Automated region detection based on the contrast-to-noise ratio in near-infrared tomography. Appl opt 43(5):1053–106210.1364/AO.43.001053 ↗
39. Wang Z, Bovik AC, Sheikh HR, Simoncelli EP (2004) Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Process 13(4):600–61210.1109/TIP.2003.819861 ↗
40. Wang L (2009) Photoacoustic imaging and spectroscopy. CRC Press, Boca Raton
41. Wang K, Su R, Oraevsky AA, Anastasio MA (2012a) Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography. Phys Med Biol 57(17):539910.1088/0031-9155/57/17/5399 ↗
42. Wang L, Hu S (2012b) Photoacoustic tomography: in vivo imaging from organelles to organs. Science 335(6075):1458–146210.1126/science.1216210 ↗
43. Wang L, Gao L (2014) Photoacoustic microscopy and computed tomography: from bench to bedside. Ann Rev Biomed Eng 16:155–18510.1146/annurev-bioeng-071813-104553 ↗
44. Wu M, Zhu A, Wang Z (1987) Interactions of ethanol with clean and oxygen-preadsorbed surfaces of polycrystalline ag studied by photoacoustic spectroscopy. Phys Rev B 36(18):982410.1103/PhysRevB.36.9824 ↗
45. Xu M, Wang LV (2006) Photoacoustic imaging in biomedicine. Rev Sci Instrum 77 (4):04110110.1063/1.2195024 ↗
46. Yuan Z, Wu C, Zhao H, Jiang H (2005) Imaging of small nanoparticle-containing objects by finite-element-based photoacoustic tomography. Opt Lett 30(22):3054–305610.1364/OL.30.003054 ↗
47. Zeng L, Xing D, Gu H, Yang D, Yang S, Xiang L (2007) High antinoise photoacoustic tomography based on a modified filtered backprojection algorithm with combination wavelet. Med Phys 34(2):556–56310.1118/1.2426406 ↗
48. Zhang HF, Maslov K, Stoica G, Wang L (2006) Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging. Nat Biotechnol 24(7):848–85110.1038/nbt1220 ↗
49. Zhong J, Yang S (2014) Contrast-enhanced photoacoustic imaging using indocyanine green-containing nanoparticles. J Innov Opt Health Sci 7(01):135002910.1142/S1793545813500296 ↗
50. Zhou Y, Zhang C, Yao DK, Wang LV (2012) Photoacoustic microscopy of bilirubin in tissue phantoms. J Biomed Opt 17(12):12601910.1117/1.JBO.17.12.126019 ↗