journal article·2019-07

Conformational changes in self-assembled monolayers of 4-pyridineethanethiol and 2-aminoethanethiol on the gold nanoparticle-graphene oxide composite and advantages in Hg(II) determination

Pham Hong Phong, Dang Thanh Huyen, Vu Duc Loi, Vu Thi Thu Ha, Nguyen Thi Cam Ha, Nguyen Ngoc Ha, Le Minh Thanh

Journal of Nanoparticle Research· Volume 21· Issue 7
Publisher page

Abstract

In this study, the advance in modification of glassy carbon electrode (GCE) has been further developed for enhancing advantages in Hg(II) determination by differential pulse voltammetry. A composite of gold nanoparticles (AuNPs) and graphene oxide (GO) was first produced under the reduced potential of Au(III). The composite was then modified with self-assembled monolayer (SAMs) of 4-pyridineethanethiol (PET), which followed by an introduction of 2-aminoethanethiol (AET). Properties of the synthesized AuNPs and the modified SAMs were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), cyclic voltammetry (CV), and infrared reflection absorption spectroscopy. The results indicated that the presence of GO did not only increase the active surface area, but also involved in the intermolecular interactions. The latter property which is similar to the role of AET led to reduction of the highly ordered state of alkyl chains and conformations of terminated groups in alkanethiolates. This postulation was in good agreement with the interaction energy calculated by density functional theory (DFT). The influence of various parameters on the voltammetric response of Hg(II) was also investigated. Under the optimized conditions, the modified GCE offered higher sensitivity in the Hg(II) determination. The linear correspondence of the peak current response to the concentration of Hg(II) was from 0.149 to 17.421 nM with a correlation coefficient of 0.999, and with the detection limit of 0.012 nM (signal/noise = 3). The modified GCE was also employed to determine Hg(II) in sampled water collected in different local areas, which showed satisfactory results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical Analysis and Applications · Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (65)

Show source-provided references
1. Abollino O, Giacomino A, Malandrino M, Piscionieri G, Mentasti E (2008) Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode. Electroanal 20:75–83. https://doi.org/10.1002/elan.20070404410.1002/elan.200704044 ↗
2. Adam RN (1969) Electrochemistry at solid electrodes (monographs in electroanalytical chemistry and electrochemistry (1969), pp.402. https://doi.org/10.1002/ange.1970082192210.1002/ange.19700821922 ↗
3. Bard AJ, Faukner LR (2001) Electrochemical methods and fundamentals and application, John Wiley & Sons, Inc, chapter 5, pp.166–167.
4. Bates N (2003) Metallic and inorganic mercury poisoning. J Emerg Nurs 11:25–31. https://doi.org/10.7748/en2003.04.11.1.25.c111010.7748/en2003.04.11.1.25.c1110 ↗
5. Bernalte E, Sanchez CM, Gil EP (2012) Gold nanoparticles-modified screen-printed carbon electrodes for anodic stripping voltammetric determination of mercury in ambient water samples. Sensors Actuators B 161:669–674. https://doi.org/10.1016/j.snb.2011.10.08810.1016/j.snb.2011.10.088 ↗
6. Burshtain D, Mandler D (2005) Studying the binding of Cd(II) by –mercaptoalkanoic acid self-assembled monolayers by cyclic voltammetry and scanning electrochemical microscopy (SECM). J Electroanal Chem 581:310–319. https://doi.org/10.1016/j.jelechem.2005.05.00610.1016/j.jelechem.2005.05.006 ↗
7. Chen D, Zhuang X, Zhai J et al (2018) Preparation of highly sensitive Pt nanoparticles-carbon quantum dots/ionic liquid functionalized graphene oxide nanocomposites and application for H2O2 detection. Sensors Actuators B Chem 255:1500–1506. https://doi.org/10.1016/j.snb.2017.08.15610.1016/j.snb.2017.08.156 ↗
8. Chow E, Hibbert DB, Gooding JJ (2005) Voltammetric detection of cadmium ions at glutathione-modified electrodes. Analyst 130:831–837. https://doi.org/10.1039/B416831C10.1039/B416831C ↗
9. Deng W, Tan Y, Li Y, Wen Y, Su Z, Huang Z, Huang S, Meng Y, Xie Q, Luo Y, Yao S (2010) Square wave voltammetric determination of Hg(II) using thiol functionalized chitosan-multiwalled carbon nanotubes nanocomposite film electrode. Microchim Acta 169:367–373. https://doi.org/10.1007/s00604-010-0366-510.1007/s00604-010-0366-5 ↗
10. Devi NR, Sasidharan M, Sundramoorthy AK (2018) Gold nanoparticles-thiol-functionalized reduced graphene oxide coated electrochemical sensor system for selective detection of mercury ion. J Electrochem Soc 165:B3046–B3053. https://doi.org/10.1149/2.0081808jes10.1149/2.0081808jes ↗
11. Du Y, Zhao W, Xu JJ, Chen HY (2009) Electrochemical determination of arsenite in neutral media on reusable gold nanostructured films. Talanta 79:243–248. https://doi.org/10.1016/j.talanta.2009.03.03710.1016/j.talanta.2009.03.037 ↗
12. Filho NLD, Carmo DR, Rosa AH (2006) An electroanalyticak application of 2-aminothiazole-modified solica gel after adsorption and separation of Hg(II) from heavy metals in aqueous solution. Electrochim Acta 52:956–972. https://doi.org/10.1016/j.electacta.2006.06.03310.1016/j.electacta.2006.06.033 ↗
13. Finot MO, Dermott MTM (2000) Characterization of n-alkanethiolate monolayer adsorbed to electrochemically deposited gold nanoparticles on glassy carbon electrode. J Electroanal Chem 488:125–132. https://doi.org/10.1016/S0022-0728(00)00201-110.1016/S0022-0728(00)00201-1 ↗
14. Gan H, Pan D, Wang C, Zhu R (2017) Controlled synthesis of dendritic gold nanostructures by graphene oxide and their morphology-dependent performance for iron detection in coastal water. RSC Adv 7:15833–15,841. https://doi.org/10.1039/C6RA27075A10.1039/C6RA27075A ↗
15. Gao F, El-Deab MS, Okajima T, Ohsaka T (2005) Electrochemical preparation of a Au crystal with peculiar morphology and unique growth orientation and its catalysis for oxygen reduction. J Electrochem Soc 15:A1226–A1232. https://doi.org/10.1149/1.190602310.1149/1.1906023 ↗
16. Glaspell G, Hassan HM, Elzatahry A, Fuoco L, Radwan NR, El-Shall MS (2010) Nanocatalysis on tailored shape supports: Au and Pd nanoparticles supported on MgO nanocubes and ZnO nanobelts. J Phys Chem 110:21387–21,393 http://pubs.acs.org/doi/10.1021/jp065103410.1021/jp0651034 ↗
17. Goncalves G, Marques PAAP, Granadeiro CM, Nogueira HIS, Singh MK, Grácio J (2009) Surface modification of graphene nanosheets with gold nanoparticles: the role of oxygen moieties at graphene surface on gold nucleation and growth. Chem Mater 21:4796–4802. https://doi.org/10.1021/cm901052s10.1021/cm901052s ↗
18. Gong J, Zhou T, Song D, Zhang L, Hu X (2010) Stripping voltammetric detection of Hg(II) based on a bimetallic Au-Pt inorganic-organic hybrid nanocomposite modified glassy carbon electrode. Anal Chem 82:567–573. https://doi.org/10.1021/ac901846a10.1021/ac901846a ↗
19. Gupta MC (2008) Atomic and molecular spectroscopy, New Age International Publishers chapter 8, pp.231–232.
20. Hezard T, Fajerwerg K, Evrard D, Collière V, Behra P, Gros P (2012) Influences of the gold nanoparticle electrodeposition method on Hg(II) trace electrochemical detection. Electrochim Acta 73:15–22. https://doi.org/10.1016/j.electacta.2011.10.10110.1016/j.electacta.2011.10.101 ↗
21. Hu K, Bard AJ (1998) In situ monitoring of kinetics of charged thiol adsorption on gold using an atomic force microscope. Langmuir 14:4790–4794. https://doi.org/10.1021/la971363o10.1021/la971363o ↗
22. Huan TN, Ganesh T, Kim KS, Kim S, Han SH, Chung H (2011) Three-dimensional gold nanodendrite network porous structure and its application for an electrochemical sensing. Biosens Bioelectron 27:183–186. https://doi.org/10.1016/j.bios.2011.06.01110.1016/j.bios.2011.06.011 ↗
23. Huang H, Chen T, Ma H (2014) Ultrasensitive and simultaneous detection of heavy metal ions based on three-dimensional graphene-carbon nanotubes hybrid electrode materials. Anal Chem 852:45–54. https://doi.org/10.1016/j.aca.2014.09.01010.1016/j.aca.2014.09.010 ↗
24. Hummers WS, Offeman RE (1958) Preparation of graphene oxide. J Am Chem Soc 80:1339–1339. https://doi.org/10.1021/ja01539a01710.1021/ja01539a017 ↗
25. Jiang R, Liu N, Gao S, Mamat X, Su Y, Wagberg T, Li Y, Hu X, Hu G (2018) A facile electrochemical sensor based on PyTS-CNTs for simultaneous determination of cadmium and lead ions. Sensor 18:1567–1582. https://doi.org/10.3390/s1805156710.3390/s18051567 ↗
26. Ju H, Leech D (2000) Electrochemical study of a metallothionein modified gold disk electrode and its action on Hg(II) cations. J Electroanal Chem 484:150–156. https://doi.org/10.1016/S0022-0728(00)00071-110.1016/S0022-0728(00)00071-1 ↗
27. Khani H, Rofouei MK, Arab P, Gupta VK, Vafaei Z (2010) Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: application to potentiometry monitoring of Hg(II). Hazard Mater 183:402–409. https://doi.org/10.1016/j.jhazmat.2010.07.03910.1016/j.jhazmat.2010.07.039 ↗
28. Lee PM, Wang Z, Liu X, Chen Z, Liu E (2005) Glassy carbon electrode modified by graphene-gold nanocomposite coating for detection of trace lead ions in acetate buffer solution. Thin Solid Films 584:85–89. https://doi.org/10.1016/j.tsf.2015.03.01710.1016/j.tsf.2015.03.017 ↗
29. Lee C, Wei X, Kysar JW, Hone J (2008) Measurement of the elastic properties and intrinsic strength of monolayer graphene. Science 321:385–385. https://doi.org/10.1126/science.115799610.1126/science.1157996 ↗
30. Li Y, Huang Q, Xie Q, Sun L, Gu T, Li Z, Bu L, Yao S, Tu Z, Luo Z, Luo S (2013) Electrodeposition of electroreduced graphene oxide-Au nanoparticles composite film at glassy carbon electrode for anodic stripping voltammetric analysis of trace arsenic (III). Sensors Actuators B 188:894–901. https://doi.org/10.1016/j.snb.2013.07.11310.1016/j.snb.2013.07.113 ↗
31. Liu Y, Su G, Zhang B, Jiang G, Yan B (2011) Nanoparticle-based strategies for detection and recommendation of environmental pollutants. Analyst 136:872–877. https://doi.org/10.1039/c0an00905a10.1039/c0an00905a ↗
32. Malel E, Sinha JK, Zawisza I, Wittstock G, Mandler D (2008) Electrochemical detection of Cd(II) ions by self-assembled monolayer of 1,9-nonanedithiol on gold. Electrochim Acta 53:6753–6758. https://doi.org/10.1016/j.electacta.2008.02.03310.1016/j.electacta.2008.02.033 ↗
33. Mališíc M, Janoševíc A, Paunlovíc ŠB, Stojkovíc L, Ćiríc-Marjanovíc G (2012) Exploration of MnO2 carbon composites and their application to simultaneous electroanalytical determination of Pb(II) and Cu(II). Electrochim Acta 74:158–164. https://doi.org/10.1016/j.electacta.2012.04.04910.1016/j.electacta.2012.04.049 ↗
34. Matlou GG, Nkosi D, Pillay K, Arotiba O (2016) Electrochemical detection of Hg(II) in water using self assembled single walled carbon nanotube-poly(m-amino benzene sulfonic acid) on gold electrode. Sen Bio Sen Res 10:27–33. https://doi.org/10.1016/j.sbsr.2016.08.00310.1016/j.sbsr.2016.08.003 ↗
35. Mendez SS, Renendo OD, Martinez MJA (2009) Determination of arsenic(III) using platinum nanoparticle-modified screen carbon-based electrodes. Electroanal 21:635–639. https://doi.org/10.1002/elan.20080438910.1002/elan.200804389 ↗
36. Musameh MH, Hickey M, Kyratzis IL (2011) Carbon nanotube based extraction and electrochemical detection of heavy metals. Res Chem Intermed 37:675–689. https://doi.org/10.1007/s11164-011-0307-x10.1007/s11164-011-0307-x ↗
37. Nishiyama K, Tsuchiyama M, Kubo A, Seriu H, Miyazaki S, Yoshimoto S, Taniguchi I (2008) Conformational change in 4-pyridineethanethiol self-assembled monolayers on Au(111) driven by protonation/deprotonation in electrolyte solutions. Phys Chem Chem Phys 10:6935–6939. https://doi.org/10.1039/B810777G10.1039/B810777G ↗
38. Nuzzo RG, Dubois LH, Allara DL (1990) Fundamental studies of microscopic wetting on organic surface.1. Formation and structural characterization of a self-consistent series of polyfunctional organic monolayers. J Am Chem Soc 112:558–569. https://doi.org/10.1021/ja00158a01210.1021/ja00158a012 ↗
39. Phong PH, Anh NH, Hung LQ, Ha NTC, Ha VTT (2013a) Voltammetric behavior of two stacking layers of copper bound 3- mercaptopropionic self-assembled monolayer on gold electrode and application in enhancement of detection of Cu(II). Asian J Chem 25:1456–1460. https://doi.org/10.14233/ajchem.2013.1307710.14233/ajchem.2013.13077 ↗
40. Phong PH, Anh NH, Hung LQ, Ha NTC, Ha VTT (2013b) Highly sensitive determination of Hg(II) using self-assembled monolayer of 4-pyridienethanethiol on gold nanoparticles modified-glassy carbon electrode pretreated by exclusively cathodic polarization. Asian J Chem 25:6562–6568. https://doi.org/10.14233/ajchem.2013.1443210.14233/ajchem.2013.14432 ↗
41. Phong PH, Huyen DT, Anh NH, Ha VTT (2015) Effects of introducing 2-aminoethanethiol into 4-pyridineethanthiol self-assembled monolayer applicable to enhance sensitivity of Hg(II) electrochemical analysis. J New Mater Electrochem Syst 18:207–212. https://doi.org/10.14447/jnmes.v18i4.34910.14447/jnmes.v18i4.349 ↗
42. Porter MD, Bright TB, Allara DL, Chidsey CED (1987) Spontaneously organized molecular assemblies. 4. structural characterization of n-alkyl thiol monolayers on gold by optical ellipsometry, infrared spectroscopy, and electrochemistry. J Am Chem Soc 109:3559–3568. https://doi.org/10.1021/ja00246a01110.1021/ja00246a011 ↗
43. Sawaguchi T, Mizutani F, Yoshimoto S, Taniguchi I (2000) Voltammetric and in situ STM studies on self-assembled monolayers of 4-mercaptopyridine, 2 mercaptopyridine and thiolphenol on Au(111) electrodes. Electrochim Acta 45:2861–2867. https://doi.org/10.1016/S0013-4686(00)00360-110.1016/S0013-4686(00)00360-1 ↗
44. Shein JB, Lai LMH, Eggers PK, Paddon-Row MN, Gooding JJ (2009) Formation of efficient electron transfer pathways by adsorbing gold nanoparticles to self-assembled monolayer modified electrodes. Langmuir 25:11121–11,128. https://doi.org/10.1021/la901421m10.1021/la901421m ↗
45. Shervedani RK, Mozaffari SA (2006) Copper(II) nanosensor based on a gold cysteamine self-assembled monolayer functionalized with salicylaldehyde. Anal Chem 78:4957–4963. https://doi.org/10.1021/ac052292y10.1021/ac052292y ↗
46. Shi L, Wang Y, Chu Z, Yin Y, Jiang D, Luo J, Ding S, Jin W (2017) A highly sensitive and reusable electrochemical mercury biosensor based on tuneable single-walled carbon nanotubes and a target recycling strategy. J Mater Chem B 5:1073–1080. https://doi.org/10.1039/C6TB02658C10.1039/C6TB02658C ↗
47. Shih CJ, Lin S, Sharma R, Strano MS, Blankschtein D (2012) Understanding the pH-dependent behavior of graphene oxide aqueous solutions: A comparative experimental and molecular dynamics simulation study. Langmuir 28:235–241. https://doi.org/10.1021/la203607w10.1021/la203607w ↗
48. Sierański T (2017) Discovering the stacking landscape of as pyridine-pyridine system. J Mol Model 23:338. https://doi.org/10.1007/s00894-017-3496-410.1007/s00894-017-3496-4 ↗
49. Snyder RG, Strauss HL, Elliger CA (1982) Carbon-hydrogen stretching modes and the structure of n-alkyl chains. 1. Long, disordered chains. J Phys Chem 86:5145–5150. https://doi.org/10.1021/j100223a01810.1021/j100223a018 ↗
50. Socrates G (2001) Infrared and Ranman Characteristic group frequencies Tables and Charts. John Widely & Sons, Ltd., pp. 162.
51. Suherman AL, Ngamchuea K, Tanner EEL, Sokolov SV, Holter J, Young NP, Compton RG (2017) Electrochemical detection of ultra-trace (picomolar) levels of Hg(II) using a silver nanoparticle-modified glassy carbon electrode. Anal Chem 89:7166–7173. https://doi.org/10.1021/acs.analchem.7b0130410.1021/acs.analchem.7b01304 ↗
52. Wang ZL, Gao RP, Poncharal P, de Heer WA, Dai ZR, Pan ZW (2001) Mechanic and electrostatic properties of carbon nanotubes and nanowire. Mat Sci Eng C 16:3–10. https://doi.org/10.1016/S0928-4931(01)00293-410.1016/S0928-4931(01)00293-4 ↗
53. Wang D, Zhang F, Tang J (2015) Sodium alginate decirated carbon nanotubes-graphene composite aerogel for heavy metal ions detection. Electroanal Chem 83:84–90. https://doi.org/10.5796/electrochemistry.83.8410.5796/electrochemistry.83.84 ↗
54. Wang N, Lin M, Dai H, Ma H (2016) Functional gold nanoparticles/reduced graphene oxide nanocomposites for ultrasensitive electrochemical sensing of mercury ions based on thymine-mercury-thymine structure. Biosen Bioelectro 79:320–326. https://doi.org/10.1016/j.bios.2015.12.05610.1016/j.bios.2015.12.056 ↗
55. Wang S, Zhai S, Li Y, Zhang C, Han Z, Peng R, Wang X, Lin Z, Lin L, Liu Y, Mei X, Zhang J (2018) Simultaneously detection of Pb(II) and Hg(II) using electrochemically reduced graphene oxide. Int J Electrochem Sci 13:785–796. https://doi.org/10.20964/2018.01.8410.20964/2018.01.84 ↗
56. Wei J, Yang D, Chen H, Gao Y, Li H (2014) Stripping voltammetric determination of mercury (II) based on SWCNT-PhSH modified gold electrode. Sensors Actuators B 190:968–974. https://doi.org/10.1016/j.snb.2013.09.08310.1016/j.snb.2013.09.083 ↗
57. Yasri NG, Sundrammoorthy AK, Chang WJ, Gunasekaran S (2014) Highly selective mercury detection at partially oxidized graphene/poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)nanocomposite film-modified. Frontiers in Materials 1:1–10. https://doi.org/10.3389/fmats.2014.0003310.3389/fmats.2014.00033 ↗
58. Zahra N, Kalim I, Mahmood M, Naeem N (2017) Perilous effects of heavy metals contamination on human health. Pak J Anal Environ Chem 18:1–17. https://doi.org/10.21743/pjaec/2017.06.0110.21743/pjaec/2017.06.01 ↗
59. Zhang T, Cheng Z, Wang Y, Li Z, Wang C, Li Y, Fang Y (2010) Self-assembled 1-octodecanethiol monolayers on graphene for mercury detection. Nano Lett 10:4738–4741. https://doi.org/10.1021/nl103255610.1021/nl1032556 ↗
60. Zheng B, Ding X, Zhao F (2008) Voltammetric response of glutathione and 3-mercaptopropionic acid self-assembled monolayer modified gold electrodes to Cu(II). Electroanalysis 14:651–656. https://doi.org/10.1002/1521-410910.1002/1521-4109 ↗
61. Zhou H, Wang X, Yu P, Chen X, Mao L (2012) Sensitive and selective voltammetric measurement of Hg2+ by rational covalent functionalization of graphene oxide with cysteamine. Analyst 137:305–308. https://doi.org/10.1039/C1AN15793K10.1039/C1AN15793K ↗
62. Zhuang X, Wang H, He T et al (2016a) Enhanced voltammetric determination of dopamine using a glassy carbon electrode modified with ionic liquid-functionalized graphene and carbon dots. Microchim Acta 183:3177–3182. https://doi.org/10.1007/s00604-016-1971-810.1007/s00604-016-1971-8 ↗
63. Zhuang X, Tian C, Luan F et al (2016b) One-step electrochemical fabrication of a nickel oxide nanoparticle/polyaniline nanowire/graphene oxide hybrid on a glassy carbon electrode for use as a non-enzymatic glucose biosensor. RSC Adv 6:92541–92,546. https://doi.org/10.1039/C6RA14970G10.1039/C6RA14970G ↗
64. Zhuang X, Chen D, Wang S et al (2017) Manganese dioxide nanosheet-decorated ionic liquid-functionalized graphene for electrochemical theophylline biosensing. Sensors Actuators B Chem 251:185–191. https://doi.org/10.1016/j.snb.2017.05.04910.1016/j.snb.2017.05.049 ↗
65. Zhuang X, Chen D, Zhang S et al (2018) Reduced graphene oxide functionalized with a CoS2/ionic liquid composite and decorated with gold nanoparticles for voltammetric sensing of dopamine. Microchim Acta 185:166. https://doi.org/10.1007/s00604-018-2712-y10.1007/s00604-018-2712-y ↗