journal article·2013-09

Highly sensitive detection of human IgG using a novel bio-barcode assay combined with DNA chip technology

Zhenbao Liu, Bo Zhou, Haiqing Wang, Feng Lu, Tianjun Liu, Cunxian Song, Xigang Leng

Journal of Nanoparticle Research· Volume 15· Issue 9
Publisher page

Abstract

A simple and ultrasensitive detection of human IgG based on signal amplification using a novel bio-barcode assay and DNA chip technology was developed. The sensing platform was a sandwich system made up of antibody-modified magnetic microparticles (Ab-MMPs)/human IgG/Cy3-labeled single-stranded DNA and antibody-modified gold nanoparticles (Cy3-ssDNA-Ab-AuNPs). The MMPs (2.5 μm in diameter) modified with mouse anti-human IgG monoclonal-antibodies could capture human IgG and further be separated and enriched via a magnetic field. The AuNPs (13 nm in diameter) conjugated with goat anti-human IgG polyclonal-antibodies and Cy3-ssDNA could further combine with the human IgG/Ab-MMP complex. The Cy3-ssDNA on AuNPs was then released by TCEP to hybridize with the DNA chip, thus generating a detectable signal by the fluorescence intensity of Cy3. In order to improve detection sensitivity, a three-level cascaded signal amplification was developed: (1) The MMP enrichment as the first-level; (2) Large quantities of Cy3-ssDNA on AuNPs as the second-level; (3) The Cy3-ssDNA conjugate with DNA chip as the third-level. The highly sensitive technique showed an increased response of the fluorescence intensity to the increased concentration of human IgG through a detection range from 1 pg mL−1 to 10 ng mL−1. This sensing technique could not only improve the detection sensitivity for the low concentration of human IgG but also present a robust and efficient signal amplification model. The detection method has good stability, specificity, and reproducibility and could be applied in the detection of human IgG in the real samples.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · Advanced Biosensing Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Ackerson CJ, Sykes MT, Kornberg RD (2005) Defined DNA/nanoparticle conjugates. Proc Natl Acad Sci USA 102(38):13383–1338510.1073/pnas.0506290102 ↗
2. Alivisatos AP, Johnsson KP, Peng X, Wilson TE, Loweth CJ, Bruchez MP Jr, Schultz PG (1996) Organization of ‘nanocrystal molecules’ using DNA. Nature 382(6592):609–61110.1038/382609a0 ↗
3. Ambrosi A, Castaneda MT, Killard AJ, Smyth MR, Alegret S, Merkoci A (2007) Double-codified gold nanolabels for enhanced immunoanalysis. Anal Chem 79(14):5232–524010.1021/ac070357m ↗
4. Ankarberg-Lindgren C, Norjavaara E (2008) A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children. Eur J Endocrinol 158(1):117–12410.1530/EJE-07-0403 ↗
5. Bao YP, Wei TF, Lefebvre PA, An H, He L, Kunkel GT, Muller UR (2006) Detection of protein analytes via nanoparticle-based bio bar code technology. Anal Chem 78(6):2055–205910.1021/ac051798d ↗
6. Cui R, Huang H, Yin Z, Gao D, Zhu JJ (2008) Horseradish peroxidase-functionalized gold nanoparticle label for amplified immunoanalysis based on gold nanoparticles/carbon nanotubes hybrids modified biosensor. Biosens Bioelectron 23(11):1666–167310.1016/j.bios.2008.01.034 ↗
7. Ehrhart JC, Bennetau B, Renaud L, Madrange JP, Thomas L, Morisot J, Brosseau A, Allano S, Tauc P, Tran PL (2008) A new immunosensor for breast cancer cell detection using antibody-coated long alkylsilane self-assembled monolayers in a parallel plate flow chamber. Biosens Bioelectron 24(3):467–47410.1016/j.bios.2008.04.027 ↗
8. Fernandez-Sanchez C, Pellicer E, Orozco J, Jimenez-Jorquera C, Lechuga LM, Mendoza E (2009) Plasma-activated multi-walled carbon nanotube-polystyrene composite substrates for biosensing. Nanotechnology 20(33):33550110.1088/0957-4484/20/33/335501 ↗
9. Georganopoulou DG, Chang L, Nam JM, Thaxton CS, Mufson EJ, Klein WL, Mirkin CA (2005) Nanoparticle-based detection in cerebral spinal fluid of a soluble pathogenic biomarker for Alzheimer’s disease. Proc Natl Acad Sci USA 102(7):2273–227610.1073/pnas.0409336102 ↗
10. Grabar RGF KC, Hommer MB, Natan MJ (1995) Preparation and Characterization of Au Colloid Monolayers. Anal Chem 67(4):735–74310.1021/ac00100a008 ↗
11. Han JC, Han GY (1994) A procedure for quantitative determination of tris(2-carboxyethyl)phosphine, an odorless reducing agent more stable and effective than dithiothreitol. Anal Biochem 220(1):5–1010.1006/abio.1994.1290 ↗
12. Hill HD, Mirkin CA (2006) The bio-barcode assay for the detection of protein and nucleic acid targets using DTT-induced ligand exchange. Nat Protoc 1(1):324–33610.1038/nprot.2006.51 ↗
13. Hill HD, Vega RA, Mirkin CA (2007) Nonenzymatic detection of bacterial genomic DNA using the bio bar code assay. Anal Chem 79(23):9218–922310.1021/ac701626y ↗
14. Kim N, Kim DK, Cho YJ, Moon DK, Kim WY (2008) Carp vitellogenin detection by an optical waveguide lightmode spectroscopy biosensor. Biosens Bioelectron 24(3):391–39610.1016/j.bios.2008.04.013 ↗
15. Kong XL, Qiao FY, Qi H, Li FR (2008) One-step preparation of antibody and oligonucleotide dual-labeled gold nanoparticle bio-probes and their properties. Biotechnol Lett 30(12):2071–207710.1007/s10529-008-9802-6 ↗
16. Liao Y, Yuan R, Chai Y, Zhuo Y, Yang X (2010) Study on an amperometric immunosensor based on Nafion-cysteine composite membrane for detection of carcinoembryonic antigen. Anal Biochem 402(1):47–5310.1016/j.ab.2010.03.015 ↗
17. Mirkin CA, Letsinger RL, Mucic RC, Storhoff JJ (1996) A DNA-based method for rationally assembling nanoparticles into macroscopic materials. Nature 382(6592):607–60910.1038/382607a0 ↗
18. Nam JM, Thaxton CS, Mirkin CA (2003) Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins. Science 301(5641):1884–188610.1126/science.1088755 ↗
19. Nam JM, Stoeva SI, Mirkin CA (2004) Bio-bar-code-based DNA detection with PCR-like sensitivity. J Am Chem Soc 126(19):5932–593310.1021/ja049384+ ↗
20. Oh BK, Nam JM, Lee SW, Mirkin CA (2006) A fluorophore-based bio-barcode amplification assay for proteins. Small 2(1):103–10810.1002/smll.200500260 ↗
21. Pathak S, Choi SK, Arnheim N, Thompson ME (2001) Hydroxylated quantum dots as luminescent probes for in situ hybridization. J Am Chem Soc 123(17):4103–410410.1021/ja0058334 ↗
22. Qiao F, Liu J, Li F, Kong X, Zhang H, Zhou H (2008) Antibody and DNA dual-labeled gold nanoparticles: stability and reactivity. Appl Surf Sci 254:2941–294610.1016/j.apsusc.2007.10.046 ↗
23. Qin WJ, Yung LY (2005) Nanoparticle-DNA conjugates bearing a specific number of short DNA strands by enzymatic manipulation of nanoparticle-bound DNA. Langmuir 21(24):11330–1133410.1021/la051630n ↗
24. Shen L, Chen Z, Li Y, He S, Xie S, Xu X, Liang Z, Meng X, Li Q, Zhu Z, Li M, Le XC, Shao Y (2008) Electrochemical DNAzyme sensor for lead based on amplification of DNA-Au bio-bar codes. Anal Chem 80(16):6323–632810.1021/ac800601y ↗
25. Stoeva SI, Lee JS, Thaxton CS, Mirkin CA (2006) Multiplexed DNA detection with biobarcoded nanoparticle probes. Angew Chem Int Ed Engl 45(20):3303–330610.1002/anie.200600124 ↗
26. Taton TA, Mirkin CA, Letsinger RL (2000) Scanometric DNA array detection with nanoparticle probes. Science 289(5485):1757–176010.1126/science.289.5485.1757 ↗
27. Wang Z, Yang Y, Li J, Gong J, Shen G, Yu R (2006) Organic-inorganic matrix for electrochemical immunoassay: detection of human IgG based on ZnO/chitosan composite. Talanta 69(3):686–69010.1016/j.talanta.2005.11.004 ↗
28. Wang G, Gang X, Zhou X, Zhang G, Huang H, Zhang X, Wang L (2013) Electrochemical immunosensor with graphene/gold nanoparticles platform and ferrocene derivatives label. Talanta 103:75–8010.1016/j.talanta.2012.10.008 ↗
29. Willner I, Patolsky F, Wasserman J (2001) Photoelectrochemistry with Controlled DNA-Cross-Linked CdS Nanoparticle Arrays. Angew Chem Int Ed Engl 40(10):1861–186410.1002/1521-3773(20010518)40:10<1861::AID-ANIE1861>3.0.CO;2-V ↗
30. Yang Z, Fu Z, Yan F, Liu H, Ju H (2008) A chemiluminescent immunosensor based on antibody immobilized carboxylic resin beads coupled with micro-bubble accelerated immunoreaction for fast flow-injection immunoassay. Biosens Bioelectron 24(1):35–4010.1016/j.bios.2008.03.007 ↗
31. Zanchet D, Micheel CM, Parak WJ, Gerion D, Alivisatos AP (2001) Electrophoretic Isolation of Discrete Au Nanocrystal/DNA Conjugates. Nano Lett 1(1):32–3510.1021/nl005508e ↗
32. Zhu D, Tang Y, Xing D, Chen WR (2008) PCR-free quantitative detection of genetically modified organism from raw materials. An electrochemiluminescence-based bio bar code method. Anal Chem 80(10):3566–357110.1021/ac0713306 ↗