Abstract
In this paper, the design of a Giant Magneto Resistive (GMR) sensor is optimized using single-objective optimization algorithms, for measuring magnetic nanoparticles stored in an Eppendorf tube. The iron oxide nanoparticle (Fe3O4) is employed as a magnetic nanoparticle. The variance-based sensitivity analysis is used to identify the most significant variable affecting the GMR sensitivity which is found to be the magnetic bias. As a result, using single-objective optimization algorithms, the optimal value for GMR sensor magnetic bias value (H) was computed and incorporated in the instrument design. The device thus designed was fabricated using Rapid Prototyping (RPT)-solid works. To identify the sensor response in a linear range, a couple of permanent neodymium magnets were used to provide horizontal and vertical magnetic fields for sensor bias and nanoparticle magnetization. This process gives an idea of a combined hardware-software approach, to reduce the measurement uncertainty and increase the system’s sensitivity. The proposed design achieved an output signal change of 248 mV for a magnetic particle concentration change of 1 µg. The device’s lowest measurable concentration was improved using the appropriate single-objective optimization technique, resulting in 36 ng as the lowest measurable concentration. The performance of the optimal GMR device design was analyzed for hysteresis analysis Fe3O4, Distance vs Sensor output for various input voltages, Temperature performance and SEM analysis of Fe3O4. The average nanoparticle size range is measured as 97 nm from SEM analysis.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Magnetic Field Sensors Techniques · Microfluidic and Bio-sensing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Anand G, Thyagarajan T, Ramakrishnan S (2021) “Fluorescence nanoparticle detection in a liquid sample using the smartphone for biomedical application fluorescence nanoparticle detection in a liquid sample using the smartphone for biomedical application,” J Fluroscence, pp. 0–8. https://doi.org/10.1007/s10895-021-02799-w10.1007/s10895-021-02799-w ↗
2. Anand G, Thyagarajan T, Aashique Roshan B, Rajeshwar L, Shyam Balaji R (2022) Signal conditioning circuits for GMR sensor in biomedical applications. In: Subramani C, Vijayakumar K, Dakyo B, Dash SS (eds) Proceedings of international conference on power electronics and renewable energy Systems. Lecture notes in electrical engineering, vol 795. Springer, Singapore. https://doi.org/10.1007/978-981-16-4943-1_1010.1007/978-981-16-4943-1_10 ↗
3. Atalay S, Kolat VS, Atalay FE, Bayri N, Kaya H, Izgi T (2018) Magnetoelastic sensor for magnetic nanoparticle detection. J Magn Magn Mater 465:151–155. https://doi.org/10.1016/j.jmmm.2018.05.10810.1016/j.jmmm.2018.05.108 ↗
4. Behera B et al (2021) Design and development of GMR based low range pressure sensor for medical ventilator application. Sensors Actuators, A Phys 321:1–14. https://doi.org/10.1016/j.sna.2021.11258110.1016/j.sna.2021.112581 ↗
5. Bhaskarrao NK, Anoop CS, Dutta PK (2017) “A simple signal conditioner for tunneling magneto-resistance based angle sensor,” 2016 IEEE Annu. India Conf. INDICON 2016, pp. 1–6. https://doi.org/10.1109/INDICON.2016.783906510.1109/INDICON.2016.7839065 ↗
6. Chakkarapani K, Thangavelu T, Dharmalingam K, Thandavarayan P (2019) Multiobjective design optimization and analysis of magnetic flux distribution for slotless permanent magnet brushless DC motor using evolutionary algorithms. J Magn Magn Mater 476(2018):524–537. https://doi.org/10.1016/j.jmmm.2019.01.02910.1016/j.jmmm.2019.01.029 ↗
7. Crespo RD, Elbaile L, Carrizo J, García JA (2018) Optimizing the sensitivity of a GMR sensor for superparamagnetic nanoparticles detection: micromagnetic simulation. J Magn Magn Mater 446:37–43. https://doi.org/10.1016/j.jmmm.2017.08.06610.1016/j.jmmm.2017.08.066 ↗
8. Daughton JM (2000) GMR and SDT sensor applications. IEEE Trans. Magn. 36(5 I):2773–2778. https://doi.org/10.1109/20.90858610.1109/20.908586 ↗
9. Djamal M, Ramli R (2017) Giant magnetoresistance sensors based on ferrite material and its applications. Bandung10.5772/intechopen.70548 ↗
10. Elangovan K, Anoop CS (2020) “A digital signal-conditioner for resistive sensors and its utility for linearizing GMR-based magnetometer,” 2020 IEEE Sensors Appl. Symp. SAS 2020 - Proc. https://doi.org/10.1109/SAS48726.2020.9220031.10.1109/SAS48726.2020.9220031 ↗
11. Laha SS (2015) “Understanding the physics of magnetic nanoparticles and their applications in the biomedical field,” ProQuest Diss. Theses, p. 139, [Online]. Available: http://search.proquest.com/docview/1728804023?accountid=14701%5Cnhttp://sfx.scholarsportal.info/ottawa?url_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&genre=dissertations+%26+theses&sid=ProQ:ProQuest+Dissertations+%26+Theses+Global&atitl
12. Lee CP, Lai MF, Huang HT, Lin CW, Wei ZH (2014) Wheatstone bridge giant-magnetoresistance based cell counter. Biosens Bioelectron 57:48–53. https://doi.org/10.1016/j.bios.2014.01.02810.1016/j.bios.2014.01.028 ↗
13. Li Y et al (2010) Nanomagnetic competition assay for low-abundance protein biomarker quantification in unprocessed human sera. J Am Chem Soc 132(12):4388–4392. https://doi.org/10.1021/ja910406a10.1021/ja910406a ↗
14. Li L, Mak KY, Leung CW, Ng SM, Lei ZQ, Pong PWT (2013) Detection of 10-nm superparamagnetic iron oxide nanoparticles using exchange-biased GMR sensors in wheatstone bridge. IEEE Trans Magn 49(7):4056–4059. https://doi.org/10.1109/TMAG.2013.223788910.1109/TMAG.2013.2237889 ↗
15. Manteca A, Mujika M, Arana S (2011) GMR sensors: magnetoresistive behaviour optimization for biological detection by means of superparamagnetic nanoparticles. Biosens Bioelectron 26(8):3705–3709. https://doi.org/10.1016/j.bios.2011.02.01310.1016/j.bios.2011.02.013 ↗
16. Murzin D et al (2020) Ultrasensitive magnetic field sensors for biomedical applications. Sensors (switzerland) 20(6):1–32. https://doi.org/10.3390/s2006156910.3390/s20061569 ↗
17. Mușuroi C, Oproiu M, Volmer M, Neamtu J, Avram M, Helerea E (2021) Low field optimization of a non-contacting high-sensitivity gmr-based dc/ac current sensor. Sensors 21(7):1–20. https://doi.org/10.3390/s2107256410.3390/s21072564 ↗
18. Park J (2015) Superparamagnetic nanoparticle quantification using a giant magnetoresistive sensor and permanent magnets. J Magn Magn Mater 389:56–60. https://doi.org/10.1016/j.jmmm.2015.04.04910.1016/j.jmmm.2015.04.049 ↗
19. Park J (2016) A giant magnetoresistive reader platform for quantitative lateral fl ow immunoassays. Sensors Actuators A Phys 250:55–5910.1016/j.sna.2016.09.016 ↗
20. Reig C, Cubells-Beltrán MD, Muñoz DR (2009) Magnetic field sensors based on Giant Magnetoresistance (GMR) technology: Applications in electrical current sensing. Sensors 9(10):7919–7942. https://doi.org/10.3390/s9100791910.3390/s91007919 ↗
21. Smith CH, Schneider RW (1998) Magnetic field sensing utilizing GMR materials. Sens Rev 18(4):230–236. https://doi.org/10.1108/0260228981024059210.1108/02602289810240592 ↗
22. Sun Y, Fang L, Wan Y, Gu Z (2018) Pathogenic detection and phenotype using magnetic nanoparticle-urease nanosensor. Sensors Actuators, B Chem 259:428–432. https://doi.org/10.1016/j.snb.2017.12.09510.1016/j.snb.2017.12.095 ↗
23. Xu J et al (2016) Detection of the concentration of MnFe2O4 magnetic microparticles using giant magnetoresistance sensors. IEEE Trans Magn 52(4):10–1310.1109/TMAG.2015.2497249 ↗
24. Zhang D, Pan Z, Zhou H, Zhang W (2016) Magnetic sensor based on giant magneto-impedance effect using the self-regulating technology on the bias magnetic field. Sensors Actuators, A Phys 249:225–230. https://doi.org/10.1016/j.sna.2016.09.00510.1016/j.sna.2016.09.005 ↗