Abstract
The preparation of pH-sensitive nanospheres by emulsion polymerization for the detection of trace levels of ammonia is described. A fluorescent, polymerizable xanthene dye was copolymerized with styrene, crosslinkers and further copolymers aimed at enhancing the sensitivity to obtain materials for sensing of ammonia. A half-seeded technique was used to obtain stable emulsions of the monomers which were cured to obtain nanospheres with covalently attached active components. The nanospheres were embedded in a silicon matrix and the sensor films obtained were investigated regarding their response to ammonia at concentrations between 25 and 1,000 ppb. Sensors containing polystyrene nanospheres crosslinked with divinylbenzene showed the best performance in ammonia measurements exhibiting detection limits (LODs) of less than 25 ppb ammonia.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Gas Sensing Nanomaterials and Sensors · Advanced Chemical Sensor Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Brasuel M, Kopelman R, Miller TJ, Tjalkens R, Philbert MA (2001) Fluorescent nanosensors for intracellular chemical analysis: decyl methacrylate liquid polymer matrix and ion-exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells. Anal Chem 73:2221–222810.1021/ac0012041 ↗
2. Capek I, Lin SY, Hsu TJ, Chern CS (2000) Effect of temperature on styrene emulsion polymerization in the presence of sodium dodecyl sulphate. J Polym Sci 38:1477–148610.1002/(SICI)1099-0518(20000501)38:9<1477::AID-POLA10>3.0.CO;2-Y ↗
3. Caruso F (2004) Colloids and colloids assemblies. Wiley-VHC, Weinheim, Germany
4. Charreyre MT, Zhang P, Winnik MA, Pichot C, Graillat C (1995) Adsorption of Rhodamine 6G onto polystyrene latex particles with sulphate groups at the surface. J Colloid Interface Sci 170:374–38210.1006/jcis.1995.1115 ↗
5. Holzapfel V, Musyanovych A, Landfester K, Lorenz MR, Mailänder V (2005) Preparation of fluorescent carboxyl and amino functionalized polystyrene particles by miniemulsion polymerization as markers for cells. Macromol Chem Phys 206:2440–244910.1002/macp.200500372 ↗
6. Ji J, Rosenzweig N, Griffin C, Rosenzweig Z (2000) Synthesis and application of submicrometer fluorescence sensing particles for lysosomal pH measurements in murine macrophages. Anal Chem 72:3497–350310.1021/ac000080p ↗
7. Lin SY, Capek I, Hsu TJ, Chern CS (1999) On the emulsion polymerization of styrene in the presence of a non-ionic emulsifier. J Polym Sci 37:4422–443210.1002/(SICI)1099-0518(19991201)37:23<4422::AID-POLA19>3.0.CO;2-V ↗
8. Ma A, Rosenzweig Z (2005) Synthesis and analytical properties of micrometric biosensing lipobeads. Anal Bioanal Chem 382:28–3610.1007/s00216-005-3186-4 ↗
9. Ozawa S, Hauser PC, Seiler K, Tan SSS, Morf WE, Simon W (1991) Ammonia-gas-selective optical sensors based on neutral ionophores. Anal Chem 63:640–64410.1021/ac00006a017 ↗
10. Timmer B, Wouter O, van den Berg A (2005) Ammonia sensors and their applications—a review. Sens Actuators B 107:666–67710.1016/j.snb.2004.11.054 ↗
11. Waich K, Mayr T, Klimant I (2007) Microsensors for detection of ammonia at ppb-concentration levels. Meas Sci Technol 18:3195–320110.1088/0957-0233/18/10/S22 ↗
12. Waich K, Mayr T, Klimant I (2008) Fluorescence sensors for trace monitoring of dissolved ammonia. Talanta 77:66–7210.1016/j.talanta.2008.05.058 ↗
13. Weidgans BM, Krause C, Klimant I, Wolfbeis OS (2004) Fluorescent pH sensors with negligible sensitivity to ionic strength. Analyst 2004:645–65010.1039/b404098h ↗
14. West SJ, Ozawa S, Seiler K, Tan SSS, Simon W (1992) Selective ionophore-based optical sensors for ammonia measurement in air. Anal Chem 64:533–54010.1021/ac00029a016 ↗
15. Xu H, Aylott JW, Kopelman R, Miller TJ, Philbert MA (2001) A real-time ratiometric method fort he determination of molecular oxygen inside lifing cells using sol–gel. Anal Chem 73:4124–413310.1021/ac0102718 ↗