Electrochemical analysis of gold-coated magnetic nanoparticles for detecting immunological interaction
Source abstract
Abstract
An electrochemical impedance immunosensor was developed for detecting the immunological interaction between human immunoglobulin (IgG) and protein A from Staphylococcus aureus based on the immobilization of human IgG on the surface of modified gold-coated magnetic nanoparticles. The nanoparticles with an Au shell and Fe oxide cores were functionalized by a self-assembled monolayer of 11-mercaptoundecanoic acid. The electrochemical analysis was conducted on the modified magnetic carbon paste electrodes with the nanoparticles. The magnetic nanoparticles were attached to the surface of the magnetic carbon paste electrodes via magnetic force. The cyclic voltammetry technique and electrochemical impedance spectroscopy measurements of the magnetic carbon paste electrodes coated with magnetic nanoparticles-human IgG complex showed changes in its alternating current (AC) response both after the modification of the surface of the electrode and the addition of protein A. The immunological interaction between human IgG on the surface of the modified magnetic carbon paste electrodes and protein A in the solution could be successfully monitored.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Force Microscopy Techniques and Applications · Advanced Biosensing Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Bouafsoun A, Helali S, Mebarek S, Zeiller C, Prigent AF, Othmane A, Kerkeni A, Jaffrezic-Renault N, Ponsonnet L (2007) Electrical probing of endothelial cell behaviour on a fibronectin/polystyrene/thiol/gold electrode by Faradaic electrochemical impedance spectroscopy (EIS). Bioelectrochemistry 70:401–407. doi: 10.1016/j.bioelechem.2006.05.01210.1016/j.bioelechem.2006.05.012 ↗
2. Briand E, Salmain M, Compere C, Pradier CM (2006) Immobilization of protein A on SAMs for the elaboration of immunosensors. Colloid Surf B 53:215–224. doi: 10.1016/j.colsurfb.2006.09.01010.1016/j.colsurfb.2006.09.010 ↗
3. Cao C, Sim SJ (2007) Signal enhancement of surface plasmon resonance immunoassay using enzyme precipitation-functionalized gold nanoparticles: a femto molar level measurement of anti-glutamic acid decarboxylase antibody. Biosens Bioelectron 22:1874–1880. doi: 10.1016/j.bios.2006.07.02110.1016/j.bios.2006.07.021 ↗
4. Chen J, Tang J, Yan F, Ju H (2006) A gold nanoparticles/sol-gel composite architecture for encapsulation of immunoconjugate for reagentless electrochemical immunoassay. Biomaterials 27:2313–2321. doi: 10.1016/j.biomaterials.2005.11.00410.1016/j.biomaterials.2005.11.004 ↗
5. Huang H, Liu Z, Yang X (2006) Application of electrochemical impedance spectroscopy for monitoring allergen-antibody reactions using gold nanoparticle-based biomolecular immobilization method. Anal Biochem 356:208–214. doi: 10.1016/j.ab.2006.05.02110.1016/j.ab.2006.05.021 ↗
6. Jeong J, Ha TH, Chung BH (2006) Enhanced reusability of hexa-arginine-tagged esterase immobilized on gold-coated magnetic nanoparticles. Anal Chim Acta 569:203–209. doi: 10.1016/j.aca.2006.03.10210.1016/j.aca.2006.03.102 ↗
7. Jie M, Ming CY, Jing D, Cheng LS, Na LH, Jun F, Xiang CY (1999) An electrochemical impedance immunoanalytical method for detecting immunological interaction of human mammary tumor associated glycoprotein and its monoclonal antibody. Electrochem Commun 1:425–428. doi: 10.1016/S1388-2481(99)00071-510.1016/S1388-2481(99)00071-5 ↗
8. Kang YS, Risbud S, Rabolt JF, Stroeve P (1996) Synthesis and characterization of nanometer-size Fe3O4 and γ-Fe2O3. Chem Mater 8:2209–2211. doi: 10.1021/cm960157j10.1021/cm960157j ↗
9. Merkoci A (2007) Electrochemical biosensing with nanoparticles. FEBS J 274:310–316. doi: 10.1111/j.1742-4658.2006.05603.x10.1111/j.1742-4658.2006.05603.x ↗
10. Navratilova I, Skaladal P (2004) The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopy. Bioelectrochemistry 62:11–18. doi: 10.1016/j.bioelechem.2003.10.00410.1016/j.bioelechem.2003.10.004 ↗
11. Pham TT, Cao C, Sim SJ (2008) Application of citrate-stabilized gold-coated ferric oxide composite nanoparticles for biological separations. J Magn Magn Mater 320:2049–2055. doi: 10.1016/j.jmmm.2008.03.01510.1016/j.jmmm.2008.03.015 ↗
12. Pumera M, Sanchez S, Ichinose I, Tang J (2007) Electrochemical nanobiosensors. Sens Actuators B 123:1195–1205. doi: 10.1016/j.snb.2006.11.01610.1016/j.snb.2006.11.016 ↗
13. Schwartz MP, Alvarez SD, Sailor MJ (2007) Porous SiO2 interferometric biosensor for quantitative determination of protein interactions: binding of protein A to immunoglobulins derived from different species. Anal Chem 79:327–334. doi: 10.1021/ac061476p10.1021/ac061476p ↗
14. Tang D, Yaun R, Chai Y, Fu Y, Dai J, Liu Y, Zhong X (2005) New amperometric and potentiometric immunosensors based on gold nanoparticles/tris(2,2′-bipyridyl)cobalt(III) multilayer films for hepatitis B surface antigen determinations. Biosens Bioelectron 21:539–546. doi: 10.1016/j.bios.2004.11.02410.1016/j.bios.2004.11.024 ↗
15. Tang D, Yuan R, Chai Y (2006a) Electrochemical immuno-bioanalysis for carcinoma antigen 125 based on thionine and gold nanoparticles-modified carbon paste interface. Anal Chim Acta 564:158–165. doi: 10.1016/j.aca.2006.01.09410.1016/j.aca.2006.01.094 ↗
16. Tang D, Yuan R, Chai Y (2006b) Magnetic core-shell Fe3O4@Ag nanoparticles coated carbon paste interface for studies of carcinoembryonic antigen in clinical immunoassay. J Phys Chem B 110:11640–11646. doi: 10.1021/jp060950s10.1021/jp060950s ↗
17. Touhami A, Jericho MH, Beveridge TJ (2007) Molecular recognition forces between immunoglobulin G and a surface protein adhesin on living Staphylococcus aureus. Langmuir 23:2755–2760. doi: 10.1021/la062893010.1021/la0628930 ↗
18. Wu L, Yan F, Ju HJ (2007) An amperometric immunosensor for separation-free immunoassay of CA125 based on its covalent immobilization coupled with thionine on carbon nanofiber. J Immunol Methods 322:12–19. doi: 10.1016/j.jim.2007.01.02610.1016/j.jim.2007.01.026 ↗
19. Zhang Y, Zeng GM, Tang L, Huang DL, Jiang XY, Chen YN (2007) A hydroquinone biosensor using modified core-shell magnetic nanoparticles supported on carbon paste electrode. Biosens Bioelectron 22:2121–2126. doi: 10.1016/j.bios.2006.09.03010.1016/j.bios.2006.09.030 ↗
20. Zhou YM, Hu SQ, Shen GL, Yu RQ (2003) An amperometric immunosensor based on an electrochemically pretreated carbon-paraffin electrode for complement III (C3) assay. Biosens Bioelectron 18:473–481. doi: 10.1016/S0956-5663(02)00146-X10.1016/S0956-5663(02)00146-X ↗
21. Zhou Y, Yuan R, Chai Y, Zhang Y, Li X, Wang N, Zhu Q (2006) Amperometric enzyme immunosensors based on layer-by-layer assembly of gold nanoparticles and thionine on Nafion modified electrode surface for α-1-fetoprotein determinations. Sens Actuators B 114:631–639. doi: 10.1016/j.snb.2005.04.05110.1016/j.snb.2005.04.051 ↗
22. Zhu X, Han K, Li G (2006) Magnetic nanoparticles applied in electrochemical detection of controllable DNA hybridization. Anal Chem 78:2447–2449. doi: 10.1021/ac051962x10.1021/ac051962x ↗