Abstract

A certified reference material, ERM-FD100, for quality assurance and validation of various nanoparticle sizing methods, was developed by the Institute for Reference Materials and Measurements. The material was prepared from an industrially sourced colloidal silica containing nanoparticles with a nominal equivalent spherical diameter of 20 nm. The homogeneity and stability of the candidate reference material was assessed by means of dynamic light scattering and centrifugal liquid sedimentation. Certification of the candidate reference material was based on a global interlaboratory comparison in which 34 laboratories participated with various analytical methods (DLS, CLS, EM, SAXS, ELS). After scrutinising the interlaboratory comparison data, 4 different certified particle size values, specific for the corresponding analytical method, could be assigned. The good comparability of results allowed the certification of the colloidal silica material for nanoparticle size analysis.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Water Quality and Pollution Assessment · Heavy metals in environment · Scientific Measurement and Uncertainty Evaluation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. Braun A, Couteau O, Franks K, Kestens V, Roebben G, Lamberty A, Linsinger TPJ (2011a) Validation of dynamic light scattering and centrifugal liquid sedimentation methods for nanoparticle characterisation. Adv Powder Technol 22:766–77010.1016/j.apt.2010.11.001 ↗
2. Braun A, Franks K, Kestens V, Roebben G, Lamberty A, Linsinger TPJ (2011b) Certification of equivalent spherical diameter of silica nanoparticles in water—ERM-FD100; EUR Report 24620, ISBN 978-92-79-18676-9. European Union, Luxembourg
3. Couteau O, Charoud-Got J, Rauscher H, Franchini F, Rossi F, Kestens V, Franks K, Roebben G (2010) A colloidal silica reference material for nanoparticle sizing by means of dynamic light scattering and centrifugal liquid sedimentation. Part Part Syst Charact 27:112–12410.1002/ppsc.200900094 ↗
4. Emons H (2006) The ‘RM family’—identification of all its members. Accredit Qual Assur 10:690–69110.1007/s00769-005-0046-z ↗
5. Glatter O, Kratky O (1982) Small angle X-ray scattering: data treatment. Academic Press, London, p 155
6. Hassellöv M, Readman JW, Ranville JF, Tiede K (2008) Nanoparticle analysis and characterization methodologies in environmental risk assessment of engineered nanoparticles. Ecotoxicology 17:344–36110.1007/s10646-008-0225-x ↗
7. IRMM (Institute for Reference Materials and Measurements) (2008) Product information sheet IRMM-304 https://irmm.jrc.ec.europa.eu/html/reference_materials_catalogue/catalogue/attachements/IRMM-304_product.pdf . Accessed Dec 14 2008
8. ISO (1996) ISO 13321. Particle size analysis—photon correlation spectroscopy. ISO, Geneva
9. ISO (2006) ISO Guide 35. Reference materials—general and statistical principles for certification. ISO, Geneva
10. ISO (2008a) ISO/TS 27687. Nanotechnologies—terminology and definitions for nano-objects—nanoparticle, nanofibre and nanoplate. ISO, Geneva
11. ISO (2008b) ISO 22412. Particle size analysis—dynamic light scattering (DLS). ISO, Geneva
12. ISO (2009) ISO Guide 34—general requirements for the competence of reference material producers. ISO, Geneva
13. ISO/IEC (1995) ISO/IEC Guide 98-3. Uncertainty of measurement—Part 3: guide to the expression of uncertainty in measurement. ISO, Geneva
14. ISO/IEC (2005) ISO/IEC 17025. General requirements for the competence of testing and calibration laboratories. ISO, Geneva
15. Lamberty A, Schimmel H, Pauwels J (1998) The study of the stability of reference materials by isochronous measurements. Fresenius J Anal Chem 360:359–36110.1007/s002160050711 ↗
16. Lamberty A, Franks K, Braun A, Kestens V, Roebben G, Linsinger TPJ (2011) Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension. J Nanopart Res 13:7317–732910.1007/s11051-011-0624-4 ↗
17. Laven J, Stein HN (2001) The electroviscous behavior of aqueous dispersions of amorphous silica (Ludox). J Colloid Interface Sci 238:8–1510.1006/jcis.2001.7452 ↗
18. Lide DR (ed) (1997) CRC handbook of chemistry and physics, 78th edn. CRC Press, Boca Raton
19. Linsinger TPJ (2010) ERM Application Note 1, www.erm-crm.org . Accessed Jan 2010
20. Linsinger TPJ, Pauwels J, van der Veen AMH, Schimmel H, Lamberty A (2001a) Homogeneity and stability of reference materials. Accredit Qual Assur 6:20–2510.1007/s007690000261 ↗
21. Linsinger TPJ, Pauwels J, Lamberty A, Schimmel HG, van der Veen AMH, Siekmann L (2001b) Estimating the uncertainty of stability for matrix CRMs. Fresenius J Anal Chem 370:183–18810.1007/s002160100719 ↗
22. Linsinger TPJ, Roebben G, Solans C, Ramsch R (2011) Reference materials for measuring the size of nanoparticles. Trends Anal Chem 30:18–2710.1016/j.trac.2010.09.005 ↗
23. NIST (National Institute of Standards and Technology) (2007) Reports of investigation, NIST RM 8011, RM 8012, and RM 8013. https://www-s.nist.gov/srmors/reports/8011.pdf , https://www-s.nist.gov/srmors/reports/8012.pdf , https://www-s.nist.gov/srmors/reports/8013.pdf . Accessed Dec 14 2008
24. Pauwels J, van der Veen A, Lamberty A, Schimmel H (2000) Evaluation of uncertainty of reference materials. Accredit Qual Assur 5:95–9910.1007/s007690050020 ↗
25. van der Veen AMH, Linsinger T, Pauwels J (2001) Uncertainty calculations in the certification of reference materials. 2. Homogeneity study. Accredit Qual Assur 6:26–3010.1007/s007690000238 ↗