Abstract

The performance of chemiresistor sensors made from thin film assemblies of single-wall carbon nanotubes, multiwall carbon nanotubes, reduced graphene oxide nanosheets (RGON), and gold nanoparticles (AuNP) was assessed with an immersible microelectrode array. Carbon nanotube and RGON chemiresistors were functionalized with octadecyl-1-amine and the AuNP chemiresistors were functionalized with 1-hexanethiol. The analytes examined were aqueous solutions of petroleum hydrocarbons: cyclohexane, naphthalene, benzene, toluene, ethylbenzene, and the three isomers of xylene (BTEX analytes). Titrations were performed to determine the detection limits of the different chemiresistors. The AuNP chemiresistor was the most sensitive to all the analytes with limits of detection between 0.2 and 0.6 ppm in water. In contrast, the multiwall carbon nanotube chemiresistor was the least sensitive to the analytes with limits of detection between 20 and 200 ppm. These sensitivities show that these nanomaterials have the potential, with further optimization, of being incorporated into devices that would respond to hydrocarbons in water at concentrations relevant to the regulations of the US Environmental Protection Agency. The stability of the sensors over 26 days was also assessed. Remarkably, there was a negligible change in the electrical resistance of the RGON sensors over this time. The nanotube sensors increased in resistance and the AuNP decreased in resistance over the same period. The drifting resistances did not affect the sensitivity of the nanomaterials, which remained constant with time.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Analytical Chemistry and Sensors · Advanced Chemical Sensor Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (86)

Show source-provided references
1. Abraham JK, Philip B, Witchurch A, Varadan VK, Reddy CC (2004) A compact wireless gas sensor using a carbon nanotube/PMMA thin film chemiresistor. Smart Mater Struct 13(5):1045–1049. doi: 10.1088/0964-1726/13/5/01010.1088/0964-1726/13/5/010 ↗
2. Ahn H, Chandekar A, Kang B, Sung C, Whitten JE (2004) Electrical conductivity and vapor-sensing properties of ω-(3-thienyl)alkanethiol-protected gold nanoparticle films. Chem Mater 16(17):3274–3278. doi: 10.1021/cm049794x10.1021/cm049794x ↗
3. Alwarappan S, Erdem A, Liu C, Li C-Z (2009) Probing the electrochemical properties of graphene nanosheets for biosensing applications. J Phys Chem C 113(20):8853–8857. doi: 10.1021/jp901031310.1021/jp9010313 ↗
4. Anantram MP, Léonard F (2006) Physics of carbon nanotube electronic devices. Rep Prog Phys 69(3):507–561. doi: 10.1088/0034-4885/69/3/R0110.1088/0034-4885/69/3/R01 ↗
5. Ancona MG, Snow AW, Foos EE, Kruppa W, Bass R (2006) Scaling properties of gold nanocluster chemiresistor sensors. IEEE Sens J 6(6):1403–1414. doi: 10.1109/JSEN.2006.88444710.1109/JSEN.2006.884447 ↗
6. Bekyarova E, Davis M, Burch T, Itkis ME, Zhao B, Sunshine S, Haddon RC (2004) Chemically functionalized single-walled carbon nanotubes as ammonia sensors. J Phys Chem B 108(51):19717–19720. doi: 10.1021/jp047185710.1021/jp0471857 ↗
7. Bohrer FI, Covington E, Kurdak Ç, Zellers ET (2011) Characterization of dense arrays of chemiresistor vapor sensors with submicrometer features and patterned nanoparticle interface layers. Anal Chem 83(10):3687–3695. doi: 10.1021/ac200019a10.1021/ac200019a ↗
8. Bradley K, Gabriel J-CP, Star A, Grüner G (2003) Short-channel effects in contact-passivated nanotube chemical sensors. Appl Phys Lett 83(18):3821–3823. doi: 10.1063/1.161922210.1063/1.1619222 ↗
9. Briman M, Bradley K, Gruner G (2006) Source of 1/f noise in carbon nanotube devices. J Appl Phys 100(1):013505. doi: 10.1063/1.221057010.1063/1.2210570 ↗
10. Brust M, Walker M, Bethell D, Schiffrin DJ, Whyman R (1994) Synthesis of thiol-derivatised gold nanoparticles in a two-phase liquid–liquid system. J Chem Soc Chem Commun 7:801–802. doi: 10.1039/c3994000080110.1039/C39940000801 ↗
11. Chen J, Rao AM et al (2001) Dissolution of full-length single-walled carbon nanotubes. J Phys Chem B 105(13):2525–2528. doi: 10.1021/jp002596i10.1021/jp002596i ↗
12. Chen J-H, Jang C, Xiao S, Ishigami M, Fuhrer MS (2008) Intrinsic and extrinsic performance limits of graphene devices on SiO2. Nat Nanotechnol 3(4):206–209. doi: 10.1038/nnano.2008.5810.1038/nnano.2008.58 ↗
13. Chow E, Herrmann J, Barton CS, Raguse B, Wieczorek L (2009) Inkjet-printed gold nanoparticle chemiresistors: influence of film morphology and ionic strength on the detection of organics dissolved in aqueous solution. Anal Chim Acta 632(1):135–142. doi: 10.1016/j.aca.2008.10.07010.1016/j.aca.2008.10.070 ↗
14. Chow E, Gengenbach TR, Wieczorek L, Raguse B (2010a) Detection of organics in aqueous solution using gold nanoparticles modified with mixed monolayers of 1-hexanethiol and 4-mercaptophenol. Sens Actuators B 143(2):704–711. doi: 10.1016/j.snb.2009.10.02410.1016/j.snb.2009.10.024 ↗
15. Chow E, Müller K-H, Davies E, Raguse B, Wieczorek L, Cooper JS, Hubble LJ (2010b) Characterization of the sensor response of gold nanoparticle chemiresistors. J Phys Chem C 114(41):17529–17534. doi: 10.1021/jp106055p10.1021/jp106055p ↗
16. Chow E, Raguse B, Müller K-H, Wieczorek L, Bendavid A, Cooper JS, Hubble LJ, Webster MS (2013) Influence of gold nanoparticle film porosity on the chemiresistive sensing performance. Electroanalysis 25(10):2313–2320. doi: 10.1002/elan.20130030310.1002/elan.201300303 ↗
17. Cooper JS, Raguse B, Chow E, Hubble L, Müller K-H, Wieczorek L (2010) Gold nanoparticle chemiresistor sensor array that differentiates between hydrocarbon fuels dissolved in artificial seawater. Anal Chem 82(9):3788–3795. doi: 10.1021/ac100178810.1021/ac1001788 ↗
18. Cooper JS, Chow E, Hubble LJ, Wieczorek L, Müller K-H, Raguse B (2011) Chemical sensor array that can differentiate complex hydrocarbon mixtures dissolved in seawater. Sens Lett 9(2):609–611. doi: 10.1166/sl.2011.157310.1166/sl.2011.1573 ↗
19. Dan Y, Lu Y, Kybert NJ, Luo Z, Johnson ATC (2009) Intrinsic response of graphene vapor sensors. Nano Lett 9(4):1472–1475. doi: 10.1021/nl803363710.1021/nl8033637 ↗
20. Doleman BJ, Lonergan MC, Severin EJ, Vaid TP, Lewis NS (1998) Quantitative study of the resolving power of arrays of carbon black-polymer composites in various vapor-sensing tasks. Anal Chem 70(19):4177–4190. doi: 10.1021/ac971204+10.1021/ac971204+ ↗
21. Dovgolevsky E, Konvalina G, Tisch U, Haick H (2011) Monolayer-capped cubic platinum nanoparticles for sensing nonpolar analytes in highly humid atmospheres. J Phys Chem C 114(33):14042–14049. doi: 10.1021/jp105810w10.1021/jp105810w ↗
22. Dresselhaus MS, Jorio A, Hofmann M, Dresselhaus G, Saito R (2010a) Perspectives on carbon nanotubes and graphene Raman spectroscopy. Nano Lett 10(3):751–758. doi: 10.1021/nl904286r10.1021/nl904286r ↗
23. Dresselhaus MS, Jorio A, Saito R (2010b) Characterizing graphene, graphite, and carbon nanotubes by Raman spectroscopy. Annu Rev Condens Matter Phys 1(1):89–108. doi: 10.1146/annurev-conmatphys-070909-10391910.1146/annurev-conmatphys-070909-103919 ↗
24. EPA (2010) Protection of environment. Code of Federal Regulations, Title 40, Pt. 141.61, 2010
25. Evans SD, Johnson SR, Cheng YL, Shen T (2000) Vapour sensing using hybrid organic–inorganic nanostructured materials. J Mater Chem 10(1):183–188. doi: 10.1039/A903951A10.1039/a903951a ↗
26. Franke ME, Koplin TJ, Simon U (2006) Metal and metal oxide nanoparticles in chemiresistors: does the nanoscale matter? Small 2(1):36–50. doi: 10.1002/smll.20050026110.1002/smll.200500261 ↗
27. Gittins DI, Caruso F (2001) Spontaneous phase transfer of nanoparticulate metals from organic to aqueous media. Angew Chem Int Ed 40(16):3001–3004. doi: 10.1002/1521-3773(20010817)40:16<3001:AID-ANIE3001>3.0.CO;2-510.1002/1521-3773(20010817)40:16<3001::AID-ANIE3001>3.0.CO;2-5 ↗
28. Hangarter CM, Bangar M, Mulchandani A, Myung NV (2010) Conducting polymer nanowires for chemiresistive and FET-based bio/chemical sensors. J Mater Chem 20(16):3131–3140. doi: 10.1039/b915717d10.1039/b915717d ↗
29. Helbling T, Hierold C, Durrer L, Roman C, Pohle R, Fleischer M (2008) Suspended and non-suspended carbon nanotube transistors for NO2 sensing—a qualitative comparison. Phys Status Solidi B 245(10):2326–2330. doi: 10.1002/pssb.20087959910.1002/pssb.200879599 ↗
30. Hill EW, Vijayaragahvan A, Novoselov K (2011) Graphene Sensors. IEEE Sens J 11(12):3161–3170. doi: 10.1109/JSEN.2011.216760810.1109/JSEN.2011.2167608 ↗
31. Hu N, Wang Y, Chai J, Gao R, Yang Z, Kong ES-W, Zhang Y (2012) Gas sensor based on p-phenylenediamine reduced graphene oxide. Sens Actuators B 163(1):107–114. doi: 10.1016/j.snb.2012.01.01610.1016/j.snb.2012.01.016 ↗
32. Hubble L, Wieczorek L, Müller K-H, Chow E, Cooper J, Raguse B (2010) Electrical noise in gold nanoparticle chemiresistors: effects of measurement environment and organic linker properties. Nanoscience and Nanotechnology (ICONN), 2010 International Conference on, 22–26 Feb 2010. pp 37–40. doi: 10.1109/iconn.2010.604516910.1109/ICONN.2010.6045169 ↗
33. Hummers WS Jr, Offeman RE (1958) Preparation of graphitic oxide. J Am Chem Soc 80(6):1339. doi: 10.1021/ja01539a01710.1021/ja01539a017 ↗
34. Ibañez FJ, Zamborini FP (2012) Chemiresistive sensing with chemically modified metal and alloy nanoparticles. Small 8(2):174–202. doi: 10.1002/smll.20100223210.1002/smll.201002232 ↗
35. Joseph Y, Besnard I et al (2003) Self-assembled gold nanoparticle/alkanedithiol films: preparation, electron microscopy, XPS-analysis, charge transport, and vapor-sensing properties. J Phys Chem B 107(30):7406–7413. doi: 10.1021/jp030439o10.1021/jp030439o ↗
36. Joseph Y, Krasteva N et al (2004) Gold-nanoparticle/organic linker films: self-assembly, electronic and structural characterisation, composition and vapour sensitivity. Faraday Discuss 125:77–97. doi: 10.1039/B302678G10.1039/B302678G ↗
37. Joshi RK, Gomez H, Alvi F, Kumar A (2010) Graphene films and ribbons for sensing of O2, and 100 ppm of CO and NO2 in practical conditions. J Phys Chem C 114(14):6610–6613. doi: 10.1021/jp100343d10.1021/jp100343d ↗
38. Kong J, Franklin NR, Zhou C, Chapline MG, Peng S, Cho K, Dai H (2000) Nanotube molecular wires as chemical sensors. Science 287(5453):622–625. doi: 10.1126/science.287.5453.62210.1126/science.287.5453.622 ↗
39. Kurdak C, Kim J, Kuo A, Lucido JJ, Farina LA, Bai X, Rowe MP, Matzger AJ (2005) 1/f Noise in gold nanoparticle chemosensors. Appl Phys Lett 86(7):073506. doi: 10.1063/1.186532410.1063/1.1865324 ↗
40. Lange U, Mirsky VM (2011) Chemiresistors based on conducting polymers: a review on measurement techniques. Anal Chim Acta 687(2):105–113. doi: 10.1016/j.aca.2010.11.03010.1016/j.aca.2010.11.030 ↗
41. Li J, Lu Y, Ye Q, Cinke M, Han J, Meyyappan M (2003) Carbon nanotube sensors for gas and organic vapor detection. Nano Lett 3(7):929–933. doi: 10.1021/nl034220x10.1021/nl034220x ↗
42. Li Y, H-c Wang, M-j Yang (2007) n-Type Gas sensing characteristics of chemically modified multi-walled carbon nanotubes and PMMA composite. Sens Actuators B 121(2):496–500. doi: 10.1016/j.snb.2006.04.07410.1016/j.snb.2006.04.074 ↗
43. Liu J, Legros S, Ma G, Veinot JGC, von der Kammer F, Hofmann T (2012) Influence of surface functionalization and particle size on the aggregation kinetics of engineered nanoparticles. Chemosphere 87(8):918–924. doi: 10.1016/j.chemosphere.2012.01.04510.1016/j.chemosphere.2012.01.045 ↗
44. Lonergan MC, Severin EJ, Doleman BJ, Beaber SA, Grubbs RH, Lewis NS (1996) Array-based vapor sensing using chemically sensitive, carbon black-polymer resistors. Chem Mater 8(9):2298–2312. doi: 10.1021/cm960036j10.1021/cm960036j ↗
45. Luo Y-R (2012) Bond dissociation energies. In: Lide DL (ed) CRC handbook of chemistry and physics (Internet Version), CRC Press/Taylor and Francis, Boca Raton, pp 9–66
46. Maeng S, Moon S et al (2008) Highly sensitive NO2 sensor array based on undecorated single-walled carbon nanotube monolayer junctions. Appl Phys Lett 93(11):113111. doi: 10.1063/1.298242810.1063/1.2982428 ↗
47. Mohanty N, Berry V (2008) Graphene-based single-bacterium resolution biodevice and DNA transistor: interfacing graphene derivatives with nanoscale and microscale biocomponents. Nano Lett 8(12):4469–4476. doi: 10.1021/nl802412n10.1021/nl802412n ↗
48. Müller K-H, Herrmann J, Raguse B, Baxter G, Reda T (2002) Percolation model for electron conduction in films of metal nanoparticles linked by organic molecules. Phys Rev B 66(7):75417. doi: 10.1103/Physrevb.66.07541710.1103/PhysRevB.66.075417 ↗
49. Müller K-H, Wei G, Raguse B, Myers J (2003) Three-dimensional percolation effect on electrical conductivity in films of metal nanoparticles linked by organic molecules. Phys Rev B 68(15):155407. doi: 10.1103/PhysRevB.68.15540710.1103/PhysRevB.68.155407 ↗
50. Müller K-H, Chow E, Wieczorek L, Raguse B, Cooper JS, Hubble LJ (2011) Dynamic response of gold nanoparticle chemiresistors to organic analytes in aqueous solution. Phys Chem Chem Phys 13(40):18208–18216. doi: 10.1039/C1CP20242A10.1039/c1cp20242a ↗
51. Myers M, Cooper J, Pejcic B, Baker M, Raguse B, Wieczorek L (2011) Functionalized graphene as an aqueous phase chemiresistor sensing material. Sens Actuators B 155(1):154–158. doi: 10.1016/j.snb.2010.11.04010.1016/j.snb.2010.11.040 ↗
52. Novoselov KS, Geim AK, Morozov SV, Jiang D, Zhang Y, Dubonos SV, Grigorieva IV, Firsov AA (2004) Electric field effect in atomically thin carbon films. Science 306(5696):666–669. doi: 10.1126/science.110289610.1126/science.1102896 ↗
53. Ohno Y, Maehashi K, Yamashiro Y, Matsumoto K (2009) Electrolyte-gated graphene field-effect transistors for detecting pH and protein adsorption. Nano Lett 9(9):3318–3322. doi: 10.1021/nl901596m10.1021/nl901596m ↗
54. Ong KG, Zeng K, Grimes CA (2002) A wireless, passive carbon nanotube-based gas sensor. IEEE Sens J 2(2):82–88. doi: 10.1109/JSEN.2002.100024710.1109/JSEN.2002.1000247 ↗
55. Pejcic B, Eadington P, Ross A (2007) Environmental monitoring of hydrocarbons: a chemical sensor perspective. Environ Sci Technol 41(18):6333–6342. doi: 10.1021/es070453510.1021/es0704535 ↗
56. Peng G, Tisch U et al (2009a) Diagnosing lung cancer in exhaled breath using gold nanoparticles. Nat Nanotechnol 4:669–673. doi: 10.1038/nnano.2009.23510.1038/nnano.2009.235 ↗
57. Peng G, Tisch U, Haick H (2009b) Detection of nonpolar molecules by means of carrier scattering in random networks of carbon nanotubes: toward diagnosis of diseases via breath samples. Nano Lett 9(4):1362–1368. doi: 10.1021/nl803021810.1021/nl8030218 ↗
58. Penza M, Rossi R, Alvisi M, Signore MA, Serra E (2009) Effects of reducing interferers in a binary gas mixture on NO2 gas adsorption using carbon nanotube networked films based chemiresistors. J Phys D Appl Phys 42(7):072002. doi: 10.1088/0022-3727/42/7/07200210.1088/0022-3727/42/7/072002 ↗
59. Philip B, Abraham JK, Chandrasekhar A, Varadan VK (2003) Carbon nanotube/PMMA composite thin films for gas-sensing applications. Smart Mater Struct 12(6):935–939. doi: 10.1088/0964-1726/12/6/01010.1088/0964-1726/12/6/010 ↗
60. Raguse B, Chow E, Barton CS, Wieczorek L (2007) Gold nanoparticle chemiresistor sensors: direct sensing of organics in aqueous electrolyte solution. Anal Chem 79(19):7333–7339. doi: 10.1021/ac070887i10.1021/ac070887i ↗
61. Raguse B, Barton CS, Müller K-H, Chow E, Wieczorek L (2009) Gold nanoparticle chemiresistor sensors in aqueous solution: comparison of hydrophobic and hydrophilic nanoparticle films. J Phys Chem C 113(34):15390–15397. doi: 10.1021/Jp903445310.1021/jp9034453 ↗
62. Rider AE, Kumar S, Furman SA, Ostrikov K (2012) Self-organized Au nanoarrays on vertical graphenes: an advanced three-dimensional sensing platform. Chem Commun 48(21):2659–2661. doi: 10.1039/c2cc17326c10.1039/c2cc17326c ↗
63. Roberts ME, LeMieux MC, Bao Z (2009) Sorted and aligned single-walled carbon nanotube networks for transistor-based aqueous chemical sensors. ACS Nano 3(10):3287–3293. doi: 10.1021/nn900808b10.1021/nn900808b ↗
64. Robinson JT, Perkins FK, Snow ES, Wei Z, Sheehan PE (2008) Reduced graphene oxide molecular sensors. Nano Lett 8(10):3137–3140. doi: 10.1021/nl801300710.1021/nl8013007 ↗
65. Saha K, Agasti SS, Kim C, Li X, Rotello VM (2012) Gold nanoparticles in chemical and biological sensing. Chem Rev 112(5):2739–2779. doi: 10.1021/cr200117810.1021/cr2001178 ↗
66. Salehi-Khojin A, Khalili-Araghi F, Kuroda MA, Lin KY, Leburton J-P, Masel RI (2011) On the sensing mechanism in carbon nanotube chemiresistors. ACS Nano 5(1):153–158. doi: 10.1021/nn101995f10.1021/nn101995f ↗
67. Schedin F, Geim AK, Morozov SV, Hill EW, Blake P, Katsnelson MI, Novoselov KS (2007) Detection of individual gas molecules adsorbed on graphene. Nat Mater 6(9):652–655. doi: 10.1038/nmat196710.1038/nmat1967 ↗
68. Shao Q, Liu G, Teweldebrhan D, Balandin AA, Rumyantsev S, Shur MS, Yan D (2009) Flicker noise in bilayer graphene transistors. IEEE Electron Device Lett 30(3):288–290. doi: 10.1109/led.2008.201192910.1109/LED.2008.2011929 ↗
69. Teh K-S, Lin L (2005) MEMS sensor material based on polypyrrole-carbon nanotube nanocomposite: film deposition and characterization. J Micromech Microeng 15(11):2019–2027. doi: 10.1088/0960-1317/15/11/00510.1088/0960-1317/15/11/005 ↗
70. Terrill RH, Postlethwaite TA et al (1995) Monolayers in three dimensions: NMR, SAXS, thermal, and electron hopping studies of alkanethiol stabilized gold clusters. J Am Chem Soc 117(50):12537–12548. doi: 10.1021/ja00155a01710.1021/ja00155a017 ↗
71. Thomsen C, Reich S (2007) Raman scattering in carbon nanotubes. In: Cardona M, Merlin R (eds) Light scattering in solids IX. Springer, Berlin, pp 115–234
72. Vichchulada P, Lipscomb LD, Zhang Q, Lay MD (2009) Incorporation of single-walled carbon nanotubes into functional sensor applications. J Nanosci Nanotechnol 9(4):2189–2200. doi: 10.1166/jnn.2009.SE1110.1166/jnn.2009.SE11 ↗
73. Wang F, Swager TM (2011) Diverse chemiresistors based upon covalently modified multiwalled carbon nanotubes. J Am Chem Soc 133(29):11181–11193. doi: 10.1021/ja201860g10.1021/ja201860g ↗
74. Wang F, Gu H, Swager TM (2008) Carbon nanotube/polythiophene chemiresistive sensors for chemical warfare agents. J Am Chem Soc 130(16):5392–5393. doi: 10.1021/ja710795k10.1021/ja710795k ↗
75. Wang G, Shen X, Wang B, Yao J, Park J (2009a) Synthesis and characterisation of hydrophilic and organophilic graphene nanosheets. Carbon 47(5):1359–1364. doi: 10.1016/j.carbon.2009.01.02710.1016/j.carbon.2009.01.027 ↗
76. Wang J, Yang S, Guo D, Yu P, Li D, Ye J, Mao L (2009b) Comparative studies on electrochemical activity of graphene nanosheets and carbon nanotubes. Electrochem Commun 11(10):1892–1895. doi: 10.1016/j.elecom.2009.08.01910.1016/j.elecom.2009.08.019 ↗
77. Wang C, Yin L, Zhang L, Xiang D, Gao R (2010) Metal oxide gas sensors: sensitivity and influencing factors. Sensors 10(3):2088–2106. doi: 10.3390/s10030208810.3390/s100302088 ↗
78. Wei C, Dai L, Roy A, Tolle TB (2006) Multifunctional chemical vapor sensors of aligned carbon nanotube and polymer composites. J Am Chem Soc 128(5):1412–1413. doi: 10.1021/ja057033510.1021/ja0570335 ↗
79. Wohltjen H, Snow AW (1998) Colloidal metal-insulator-metal ensemble chemiresistor sensor. Anal Chem 70(14):2856–2859. doi: 10.1021/ac971346410.1021/ac9713464 ↗
80. Wuelfing WP, Murray RW (2002) Electron hopping through films of arenethiolate monolayer-protected gold clusters. J Phys Chem B 106(12):3139–3145. doi: 10.1021/jp013987f10.1021/jp013987f ↗
81. Wuelfing WP, Green SJ, Pietron JJ, Cliffel DE, Murray RW (2000) Electronic conductivity of solid-state, mixed-valent, monolayer-protected Au clusters. J Am Chem Soc 122(46):11465–11472. doi: 10.1021/ja002367+10.1021/ja002367+ ↗
82. Xia L, Wei Z, Wan M (2010) Conducting polymer nanostructures and their application in biosensors. J Colloid Interface Sci 341(1):1–11. doi: 10.1016/j.jcis.2009.09.02910.1016/j.jcis.2009.09.029 ↗
83. Zhang Y, Tan Y-W, Stormer HL, Kim P (2005) Experimental observation of the quantum Hall effect and Berry’s phase in graphene. Nature 438(7065):201–204. doi: 10.1038/nature0423510.1038/nature04235 ↗
84. Zhang T, Nix MB, Yoo B-Y, Deshusses MA, Myung NV (2006) Electrochemically functionalized single-walled carbon nanotube gas sensor. Electroanalysis 18(12):1153–1158. doi: 10.1002/elan.20060352710.1002/elan.200603527 ↗
85. Zhang T, Mubeen S, Myung NV, Deshusses MA (2008) Recent progress in carbon nanotube-based gas sensors. Nanotechnology 19(33):332001. doi: 10.1088/0957-4484/19/33/33200110.1088/0957-4484/19/33/332001 ↗
86. Zhao J, Buldum A, Han J, Lu JP (2002) Gas molecule adsorption in carbon nanotubes and nanotube bundles. Nanotechnology 13(2):195–200. doi: 10.1088/0957-4484/13/2/31210.1088/0957-4484/13/2/312 ↗