Am charger (tapcon & analysesysteme), were investigated on their charging performance of airborne nanoparticles. The charging probabilities for negatively and positively charged particles and the particle size conservation were measured in the diameter range of 5-40 nm using sucrose nanoparticles. Chargers were operated under various flow conditions in the range of 0.6-5.0 liters per minute. For particular experimental conditions, some deviations from the chosen theoretical model were found for all chargers. For very small particle sizes, the AC-corona charger showed particle losses at low flow rates and did not reach steady-state charge equilibrium at high flow rates. However, for all chargers, operating conditions were identified where the bipolar charge equilibrium was achieved. Practically, excellent particle size conservation was found for all three chargers.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Aerosol Filtration and Electrostatic Precipitation · Coagulation and Flocculation Studies · Electrohydrodynamics and Fluid Dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Adachi M, Kousaka Y, Okuyama K (1985) Unipolar and bipolar diffusion charging of ultrafine aerosol particles. J Aerosol Sci 16:109–12310.1016/0021-8502(85)90079-5 ↗
2. Adachi M, Pui DYH, Liu BYH (1993) Aerosol charge neutralization by a corona ionizer. Aerosol Sci Technol 18:48–5810.1080/02786829308959583 ↗
3. Alonso M, Kousaka Y, Nomura T, Hashimoto N, Hashimoto T (1997) Bipolar charging and neutralization of nanometer-sized aerosol particles. J Aerosol Sci 28:1479–149010.1016/S0021-8502(97)00036-0 ↗
4. Baron PA, Willeke K (2005) Aerosol measurement: principles, techniques, and applications, 2nd edn. Wiley, New York
5. Chen D-R, Pui DYH, Kaufman SL (1995) Electrospraying of conducting liquids for monodisperse aerosol generation in the 4 nm to 1.8 μm diameter range. J Aerosol Sci 26:963–97710.1016/0021-8502(95)00027-A ↗
6. Covert D, Wiedensohler A, Russell L (1997) Particle charging and transmission efficiencies of aerosol charge neutralizes. Aerosol Sci Technol 27:206–21410.1080/02786829708965467 ↗
7. Fuchs NA (1963) On the stationary charge distribution on aerosol particles in a bipolar ionic atmosphere. Geofis Pura Appl 56:185–19310.1007/BF01993343 ↗
8. Goldman M, Goldman A, Sigmond RS (1985) The corona discharge, its properties and specific uses. Pure Appl Chem 57:1353–136210.1351/pac198557091353 ↗
9. He M, Dhaniyala S (2014) Experimental characterization of flowrate-dependent bipolar diffusion charging efficiencies of sub-50 nm particles. J Aerosol Sci 76:175–18710.1016/j.jaerosci.2014.06.009 ↗
10. Hoppel WA, Frick GM (1986) Ion—aerosol attachment coefficients and the steady-state charge distribution on aerosols in a bipolar ion environment. Aerosol Sci Technol 5:1–2110.1080/02786828608959073 ↗
11. Hussin A, Scheibel HG, Becker KH, Porstendörfer J (1983) Bipolar diffusion charging of aerosol particles—I: experimental results within the diameter range 4–30 nm. J Aerosol Sci 14:671–67710.1016/0021-8502(83)90071-X ↗
12. Jiang J, Kim C, Wang X, Stolzenburg MR, Kaufman SL, Qi C, Sem GJ, Sakurai H, Hama N, McMurry PH (2014) Aerosol charge fractions downstream of six bipolar chargers: effects of ion source, source activity, and flowrate. Aerosol Sci Technol 48:1207–121610.1080/02786826.2014.976333 ↗
13. Kallinger P (2010) Experimentelle Untersuchung der bipolaren Diffusionsbeladung von Aerosolen mit Weichröntgenstrahlung sowie der Nanopartikelbildung unter Weichröntgenstrahlung. Master thesis, University of Vienna
14. Kallinger P, Steiner G, Szymanski WW (2012) Characterization of four different bipolar charging devices for nanoparticle charge conditioning. J Nanopart Res 14:94410.1007/s11051-012-0944-z ↗
15. Kallinger P, Weiss VU, Lehner A, Allmaier G, Szymanski WW (2013) Analysis and handling of bio-nanoparticles and environmental nanoparticles using electrostatic aerosol mobility. Particuology 11:14–1910.1016/j.partic.2012.09.004 ↗
16. Kaufman SL (2010) Aerosol charge conditioner. US Patent No. US 7,796,727 B1
17. Knutson EO, Whitby KT (1975) Aerosol classification by electric mobility: apparatus, theory, and applications. J Aerosol Sci 6:443–45110.1016/0021-8502(75)90060-9 ↗
18. Kousaka Y, Adachi M, Okuyama K, Kitada N, Motouchi T (1983) Bipolar charging of ultrafine aerosol particles. Aerosol Sci Technol 2:421–42710.1080/02786828308958645 ↗
19. Laschober C, Kaufman SL, Reischl G, Allmaier G, Szymanski WW (2006) Comparison between an unipolar corona charger and a polonium-based bipolar neutralizer for the analysis of nanosized particles and biopolymers. J Nanosci and Nanotechnol 6:1474–148110.1166/jnn.2006.308 ↗
20. Lee HM, Kim CS, Shimada M, Okuyama K (2005) Bipolar diffusion charging for aerosol nanoparticle measurement using a soft X-ray charger. J Aerosol Sci 36:813–82910.1016/j.jaerosci.2004.10.011 ↗
21. Leong KH, Hopke PK, Stukel JJ, Wang HC (1983) Radiolytic condensation nuclei in aerosol neutralizers. J Aerosol Sci 14:23–2710.1016/0021-8502(83)90081-2 ↗
22. Millikan RA (1913) On the elementary electrical charge and the avogadro constant. Phys Rev 2:109–14310.1103/PhysRev.2.109 ↗
23. MSP Corp. (2010) MSP product information bulletin: PI-1090, Rev. C
24. Qi C, Kulkarni P (2013) Miniature dual-corona ionizer for bipolar charging of aerosol. Aerosol Sci Technol 47:81–9210.1080/02786826.2012.728301 ↗
25. Reischl GP (1991) Measurement of ambient aerosols by the differential mobility analyzer method: concepts and realization criteria for the size range between 2 and 500 nm. Aerosol Sci Technol 14:5–2410.1080/02786829108959467 ↗
26. Reischl GP, Scheibel HG, Porstendörfer J (1983) The bipolar charging of aerosols: experimental results in the size range below 20-nm particle diameter. J Colloid Interface Sci 91:272–27510.1016/0021-9797(83)90332-6 ↗
27. Reischl GP, Mäkelä JM, Karch R, Necid J (1996) Bipolar charging of ultrafine particles in the size range below 10 nm. J Aerosol Sci 27:931–94910.1016/0021-8502(96)00026-2 ↗
28. Romay FJ, Liu BYH, Pui DYH (1994) A sonic jet corona ionizer for electrostatic discharge and aerosol neutralization. Aerosol Sci Technol 20:31–4110.1080/02786829408959661 ↗
29. Shimada M, Han B, Okuyama K, Otani Y (2002) Bipolar charging of aerosol nanoparticles by a soft X-ray photoionizer. J Chem Eng Jpn 35:786–79310.1252/jcej.35.786 ↗
30. Steiner G, Reischl GP (2012) The effect of carrier gas contaminants on the charging probability of aerosols under bipolar charging conditions. J Aerosol Sci 54:21–3110.1016/j.jaerosci.2012.07.008 ↗
31. Stolzenburg MR, McMurry PH (2008) Equations governing single and tandem DMA configurations and a new lognormal approximation to the transfer function. Aerosol Sci Technol 42:421–43210.1080/02786820802157823 ↗
32. Stommel YG, Riebel U (2004) A new corona discharge-based aerosol charger for submicron particles with low initial charge. J Aerosol Sci 35:1051–106910.1016/j.jaerosci.2004.03.005 ↗
33. TSI Inc. (2003) Model 3480 electrospray aerosol generator. instruction manual, revision D
34. TSI Inc. (2012) Model 3087 advanced aerosol neutralizer spec sheet
35. Wiedensohler A (1988) An approximation of the bipolar charge distribution for particles in the submicron size range. J Aerosol Sci 19:387–38910.1016/0021-8502(88)90278-9 ↗
36. Wiedensohler A, Fissan HJ (1991) Bipolar charge distributions of aerosol particles in high-purity argon and nitrogen. Aerosol Sci Technol 14:358–36410.1080/02786829108959498 ↗
37. Wiedensohler A, Lütkemeier E, Feldpausch M, Helsper C (1986) Investigation of the bipolar charge distribution at various gas conditions. J Aerosol Sci 17:413–41610.1016/0021-8502(86)90118-7 ↗
38. Yoon YH, Bong C, Kim DS (2015) Evaluation of the performance of a soft X-ray charger for the bipolar charging of nanoparticles. Particuology 18:165–16910.1016/j.partic.2014.05.005 ↗
39. Yun KM, Lee SY, Iskandar F, Okuyama K, Tajima N (2009) Effect of X-ray energy and ionization time on the charging performance and nanoparticle formation of a soft X-ray photoionization charger. Adv Powder Technol 20:529–53610.1016/j.apt.2009.07.002 ↗
40. Zamorani E, Ottobrini G (1978) Aerosol particle neutralization to Boltzmann’s equilibrium by AC-corona discharge. J Aerosol Sci 9:31–3910.1016/0021-8502(78)90061-7 ↗