journal article·2013-06

“Real-world” precision, bias, and between-laboratory variation for surface area measurement of a titanium dioxide nanomaterial in powder form

Vincent A. Hackley, Aleksandr B. Stefaniak

Journal of Nanoparticle Research· Volume 15· Issue 6
Publisher page

Abstract

Accurate characterization of nanomaterial properties is a critical component of any nanotoxicology testing strategy. Data that describes the performance of various laboratories in measuring the characteristics of the same nanomaterial are scarce. We conducted an inter-laboratory study to evaluate "real-world" precision and bias of specific surface area measurements using a powered material containing sub-30 nm primary crystallites. Each participant was provided a sample of NIST Standard Reference Material 1898 (Titanium Dioxide Nanomaterial) and a sample preparation and analysis protocol. Based on results from 19 laboratories, overall performance was good. Estimates of precision ranged from 0.10 to 3.96 % and measurement bias was generally within ±5 % of the certified surface area value of the material. Between-laboratory variability accounted for 91 % of the total variance and is likely explained by gravimetric errors. Reliable determination of intrinsic nanomaterial properties such as surface area will permit development of protocols for toxicity testing, verification of laboratory proficiency, and consistency in interpretation of toxicity study data.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Nanoparticles: synthesis and applications · Healthcare and Environmental Waste Management · Heavy metals in environment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. ASTM C1274–00 (2006) Standard test method for advanced ceramic specific surface area by physical adsorption. ASTM International, West Conshohocken, PA
2. Badalyan A, Pendleton P (2003) Analysis of uncertainties in manometric gas-adsorption measurements. I: propagation of uncertainties in BET analyses. Langmuir 19:7919–7928. doi: 10.1021/la020985t10.1021/la020985t ↗
3. Boverhof DR, David RM (2010) Nanomaterial characterization: considerations and needs for hazard assessment and safety evaluation. Anal Bioanal Chem 396:953–961. doi: 10.1007/s00216-009-3103-310.1007/s00216-009-3103-3 ↗
4. Donaldson K, Stone V, Gilmour PS, Brown DM, MacNee W (2000) Ultrafine particles: mechanisms of lung injury. Philos Trans A: Math Phys Eng Sci 358:2741–274910.1098/rsta.2000.0681 ↗
5. Duffin R, Tran CL, Clouter A, Brown DM, MacNee W, Stone V, Donaldson K (2002) The importance of surface area and specific reactivity in the acute pulmonary inflammatory response to particles. Ann Occup Hyg 46(Suppl 1):242–245. doi: 10.1093/annhyg/46.suppl_1.24210.1093/annhyg/46.suppl_1.242 ↗
6. Hassellöv M, Readman JW, Ranville JF, Tiede K (2008) Nanoparticle analysis and characterization methodologies in environmental risk assessment of engineered nanoparticles. Ecotoxicology 17:344–361. doi: 10.1007/s10646-008-0225-x10.1007/s10646-008-0225-x ↗
7. ISO/DIS 9277 (2008) Determination of the specific surface area of solids by gas adsorption using the BET method. International Organization for Standardization, Geneva
8. Maier M, Hannebauer B, Holldorff H, Albers P (2006) Does lung surfactant promote disaggregation of nanostructured titanium dioxide? J Occup Environ Med 48:1314–1320. doi: 10.1097/01.jom.0000215405.72714.b210.1097/01.jom.0000215405.72714.b2 ↗
9. Monteiller C, Tran L, MacNee W, Faux S, Jones A, Miller B, Donaldson K (2007) The pro-inflammatory effects of low-toxicity low-solubility particles, nanoparticles and fine particles, on epithelial cells in vitro: the role of surface area. Occup Environ Med 64:609–615. doi: 10.1136/oem.2005.02480210.1136/oem.2005.024802 ↗
10. National Institute of Standards and Technology (2012) Standard Reference Material 1898, Certificate of Analysis ( https://www-s.nist.gov/srmors/view_cert.cfm?srm=1898 ). Accessed 16 October 2012
11. Oberdörster G, Oberdörster E, Oberdörster J (2005a) Nanotoxicology: an emerging discipline evolving from studies of ultrafine particles. Environ Health Perspect 113:823–839. doi: 10.1289/ehp.733910.1289/ehp.7339 ↗
12. Oberdörster G, Maynard A, Donaldson K, Castranova V, Fitzpatrick J, Ausman K, Carter J, Karn B, Kreyling W, Lai D, Olin S, Monteiro-Riviere N, Warheit D, Yang H (2005b) Principles for characterizing the potential human health effects from exposure to nanomaterials: elements of a screening strategy. Part Fibre Toxicol 2:8. doi: 10.1186/1743-8977-2-810.1186/1743-8977-2-8 ↗
13. OECD (December 2010) Series on the safety of manufactured nanomaterials. Report 27: List of manufactured nanomaterials and list of endpoints for phase one of the sponsorship programe for the testing of manufactured nanomaterials: Revision. Organization for Economic Cooperation and Development, Paris
14. Robichaud C, Uyar A, Darby M, Zucker L, Wiesner M (2009) Estimates of upper bounds and trends in nano-TiO2 production as a basis for exposure assessment. Environ Sci Technol 43:4227–4233. doi: 10.1021/es803254910.1021/es8032549 ↗
15. Rouquerol J, Avnir D, Fairbridge CW, Everett DH, Haynes JH, Pernicone N, Ramsay JDF, Sing KSW, Unger KK (1994) Recommendations for the characterization of porous solids. Pure Appl Chem 66:1739–1758. doi: 10.1351/pac19946608173910.1351/pac199466081739 ↗
16. Seaton A, Tran L, Aitken R, Donaldson K (2009) Nanoparticles, human health hazard and regulation. J R Soc Interface 7:S119–S129. doi: 10.1098/rsif.2009.0252.focus10.1098/rsif.2009.0252.focus ↗
17. Sing KSW, Everett DH, Haul RAW, Moscou L, Pierotti RA, Rouquerol J, Siemieniewska T (1985) Reporting physisorption data for gas/solid systems with special reference to the determination of surface area and porosity (Recommendations 1984). Pure Appl Chem 57:603–619. doi: 10.1351/pac19855704060310.1351/pac198557040603 ↗
18. Singh S, Shi T, Duffin R, Albrecht C, van Berlo D, Hohr D, Fubini B, Martra G, Fenoglio I, Borm PJA, Schins RPF (2007) Endocytosis, oxidative stress and IL-8 expression in human lung epithelial cells upon treatment with fine and ultrafine TiO2: role of the specific surface area and of surface methylation of the particles. Toxicol Appl Pharmacol 222:141–151. doi: 10.1016/j.taap.2007.05.00110.1016/j.taap.2007.05.001 ↗
19. Stefaniak AB, Hackley VA, Roebben G, Ehara K, Hankin S, Postek MT, Lynch I, Fu W-E, Linsinger TPJ, Thünemann AF (2012) Nanoscale reference materials for environmental, health, and safety measurements: needs, gaps, and opportunities. Nanotoxicology. doi: 10.3109/17435390.2012.73966410.3109/17435390.2012.739664 ↗
20. Stoeger T, Reinhard C, Takenaka S, Schroeppel A, Karg E, Ritter B, Heyder J, Schulz H (2006) Instillation of six different ultrafine carbon particles indicates a surface area threshold dose for acute lung inflammation in mice. Environ Health Perspect 114:328–333. doi: 10.1289/ehp.826610.1289/ehp.8266 ↗