3D electromagnetic modelling of new loco-regional hyperthermia applicator coupled with high resolution patient specific phantom
Source abstract
Abstract
Hyperthermia in oncology means exposing tumour to high-temperature in order to sensitize it to the main therapy modalities. There are a few clinical radio frequency-based phased-array applicators, named loco-regional hyperthermia (LHT) systems, to deliver hyperthermia to deep-seated tumours noninvasively. In the current study, a new dipole-based two ring LHT applicator was proposed and its specific absorption rate (SAR) characteristics were compared with clinical Sigma-60 system. It was demonstrated that the proposed applicator improves SAR focusing and SAR delivering capability compared to Sigma-60 applicator. However, the operating frequency of proposed applicator is higher than that of Sigma-60; therefore, higher fraction of applied energy is absorbed in less deep tissues and there is increased possibility of hot-spot occurrence compared to using Sigma-60.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Ultrasound and Hyperthermia Applications · Ultrasound Imaging and Elastography · Microwave Imaging and Scattering Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Mechanical Engineering, Shiraz University, Shiraz, Iran
References (29)
Show source-provided references
1. 10.4172/2329-6771.100011510.4172/2329-6771.1000115 ↗
2. 10.1088/0031-9155/54/12/02110.1088/0031-9155/54/12/021 ↗
3. 10.1007/s00066-012-0241-x10.1007/s00066-012-0241-x ↗
4. 10.3109/0265673090321337410.3109/02656730903213374 ↗
5. 10.3109/0265673900914094410.3109/02656739009140944 ↗
6. 10.3109/02656736.2010.53188210.3109/02656736.2010.531882 ↗
7. Fatehi D · 2007
8. 10.3109/02656736.2010.54154110.3109/02656736.2010.541541 ↗
9. 10.1080/0265673070183232610.1080/02656730701832326 ↗
10. 10.3109/02656736.2015.111766110.3109/02656736.2015.1117661 ↗
11. 10.1080/02656736.2016.121343010.1080/02656736.2016.1213430 ↗
12. 10.1080/02656739928562010.1080/026567399285620 ↗
13. Kirsch A · 201510.1007/978-3-319-11086-8 ↗
14. 10.3109/0265673910905645910.3109/02656739109056459 ↗
15. Longo TA · Int J Hyperthermia · 2016 · 6736 · 1
16. 10.1016/S0140-6736(95)90463-810.1016/S0140-6736(95)90463-8 ↗
17. 10.1080/02656739928570110.1080/026567399285701 ↗
18. 10.3892/or.2015.425210.3892/or.2015.4252 ↗
19. 10.1109/22.66413210.1109/22.664132 ↗
20. 10.1016/S0360-3016(02)04144-510.1016/S0360-3016(02)04144-5 ↗
21. 10.1093/annonc/mdf28010.1093/annonc/mdf280 ↗
22. 10.1080/026567302100003522610.1080/0265673021000035226 ↗
23. 10.1080/026567303100014081310.1080/0265673031000140813 ↗
24. 10.1016/0360-3016(96)00154-X10.1016/0360-3016(96)00154-X ↗
25. Weiser M. · Int JAppl Electrom Mech · 2009 · 30 · 265
26. Wiersma J. · 2005
27. 10.1016/S1470-2045(02)00818-510.1016/S1470-2045(02)00818-5 ↗
28. 10.3109/0265673960902352510.3109/02656739609023525 ↗
29. 10.3109/0265673960902352510.3109/02656739609023525 ↗