journal article·2025-10-02

Detection of liquid mixtures by using a novel microwave sensor based on a multi-band one-port interdigitated split ring resonator structure

Gabriela Méndez-Jerónimo, Gerardo U. Díaz-Arango, Germán A. Álvarez-Botero, Humberto Lobato-Morales, Joel Molina-Reyes

Publisher page

Abstract

The design, fabrication and measurement of a novel multi-band microwave sensor based on a one-port interdigitated split ring resonator able to detect liquids mixtures is presented in this work. The sensitive region of the proposal is 13.5 mm × 21.55 mm allowing for measuring samples with a maximum volume of 1 ml. In addition, a sample holder is proposed to avoid the possible oxidation of the electrodes due to the direct contact with the liquid under test. Empty sensor was designed to present four resonances between 0.5 and 3.2 GHz in order to operate the sensor at different bands. Experimental validation was performed using 11 mixtures of water with alcohols (isopropyl and methanol) and glyphosate-based herbicide mixtures with different concentrations between 0% and 100%. From measurements, it was found that for the herbicide case, the Band-2 (1.3 GHz − 1.6 GHz) exhibits the best response and for the alcohol-based mixtures two bands are useful for sensing applications (Band-3 between 2.1 GHz − 2.7 GHz, and Band-4 between 2.9 and 3.1 GHz) with a maximum sensitivity of 1.12%. Finally, results demonstrated that the proposed sensor could have potential for environmental applications.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microwave and Dielectric Measurement Techniques · Acoustic Wave Resonator Technologies · Molecular Spectroscopy and Structure

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electronics and Telecommunications, Ensenada Center for Scientific Research and Higher Education

Department of Electronic Instrumentation, University of Veracruz

Department of Electrical, Electronic and Communications Engineering, Public University of Navarre

Department of Electronics, National Institute for Astrophysics, Optics and Electronics

Funding

Mexican Ministry of Science, Humanities

References (24)

Show source-provided references
1. 10.3390/ma1609341610.3390/ma16093416 ↗
2. 10.1109/TMTT.1970.112740710.1109/TMTT.1970.1127407 ↗
3. 10.1109/TMTT.2018.287339510.1109/TMTT.2018.2873395 ↗
4. 10.1109/TMTT.2020.297805110.1109/TMTT.2020.2978051 ↗
5. Cinch Connectivity Solutions. 2024. SMA 50 Ohm end launch jack receptacle—round contact. 1420701801 datasheet. [accessed 2024 Jul 12]. https://www.mouser.mx/datasheet/2/643/pi-CCSJOHN-142-0701-801290116.pdf
6. 10.1109/TMTT.2019.293273710.1109/TMTT.2019.2932737 ↗
7. 10.3390/s2109314710.3390/s21093147 ↗
8. 10.1109/22.50644910.1109/22.506449 ↗
9. Greene J et al. 2019. Non-invasive monitoring of glycogen in real-time using an electromagnetic sensor. Smart Sensors. Meas Instrum. 29:1–15.
10. 10.1002/978047042389910.1002/9780470423899 ↗
11. 10.1109/LED.2022.320278910.1109/LED.2022.3202789 ↗
12. 10.1007/978-3-030-62684-6_710.1007/978-3-030-62684-6_7 ↗
13. 10.1080/03772063.2023.223187510.1080/03772063.2023.2231875 ↗
14. 10.1016/j.measurement.2020.10780510.1016/j.measurement.2020.107805 ↗
15. 10.1049/el.2015.113810.1049/el.2015.1138 ↗
16. 10.3390/s1905101310.3390/s19051013 ↗
17. 10.35414/akufemubid.136352510.35414/akufemubid.1363525 ↗
18. 10.1109/22.351810.1109/22.3518 ↗
19. 10.3390/ijerph1719710210.3390/ijerph17197102 ↗
20. 10.1364/JOSAB.43318910.1364/JOSAB.433189 ↗
21. 10.1109/LAMC.2018.869924210.1109/LAMC.2018.8699242 ↗
22. 10.1007/s11270-021-04990-y10.1007/s11270-021-04990-y ↗
23. 10.1080/17452759.2023.217025310.1080/17452759.2023.2170253 ↗
24. 10.3390/s1802065510.3390/s18020655 ↗