journal article·1996-01

Radiation Hazard Assessment of Pulsed Microwave Radars

L. Puranen, K. Jokela

Publisher page

Abstract

Observed biological effects of pulsed microwave radiation are reviewed and the exposure standards for microwave radiation are summarized. The review indicates that the microwave auditory effect is the only well-established specific effect in realistic exposure situations. The threshold for the effect depends on the energy density per pulse and may be as low as 20 mJ/m2 for people with low hearing threshold. Energy density limits have been included in the most recent exposure standards. A new battery-operated, hand-held meter developed for measurements of pulse power densities around scanning radar antennas is described, and a simple new model for the calculation of power density in the main beam of radar antennas is presented. In the near field measured values differed from the calculated values by 2-3 dB.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Electromagnetic Fields and Biological Effects · Wireless Body Area Networks

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (9)

Show source-provided references
1. European Committee for Electrotechnical Standardization (CENELEC). 1995. Human exposure to electromagnetic fields. High frequency (10 kHz to 300 GHz). European Prestandard ENV 50166–2, Brussels, Belgium.
2. Finnish Centre for Radiation and Nuclear Safety (STUK). 1992. ST-guide 9.2. Radiation safety of pulsed radar installations. Radiation safety guide 9.2. (in Finnish), Helsinki, Finland.
3. Hankin, N.N., Tell, R.A., Athey, T.W., and Janes, D.E. 1976. High power radiofrequency and microwave radiation sources: A study of relative environmental significance. Proceedings of the Ninth Midyear Topical Symposium of the Health Physics Society: 231–238.
4. Institute of Electrical and Electronic Engineers (IEEE). 1992. IEEE Standard for safety levels with respect to human exposure to radiofrequency electromagnetic fields, 3 kHz to 300 GHz. IEEE Std C95.1–1991, New York, NY, USA.
5. National Council on Radiation Protection and Measurements (NCRP). 1986. Biological effects and exposure criteria for radiofrequency electromagnetic fields. NCRP Report No. 86, USA.
6. Puranen, L. 1985. Development of microwave hazard monitor calibration system. Report S 163, Radio Laboratory, Helsinki University of Technology, Espoo, Finland.
7. Stutzman, W.L., and Thiele, G.A. 1981. Antenna Theory and Design, John Wiley St Sons, New York, USA.
8. Tell, R.A., Hankin, N.N., and Janes, D.E. 1976. Aircraft radar measurements in the near field. Proceedings of the Ninth Midyear Topical Symposium of the Health Physics Society: 239–246.
9. Wachtel, H., Brown, D., Gambrill, C., Bates, F., and Bassen, H. 1988. Reflexive movements in mice evoked selectively by high peak power microwave pulses. In: Abstracts, Tenth Annual Meeting of the Bioelectromagnetics Society, Stamford, Connecticut, USA: 58.