journal article·2007-06

The impact of high-dose implantation into manganin on its thermo-resistance properties under high pressure

R. Wiśniewski, B. Słowiński, A.Yu. Didyk, T. Wilczyńska

Vacuum· Volume 81· Issue 10
Publisher page

Abstract

Abstract Using high-dose implantation into manganin of 253 MeV Kr ions (a surface dose of 2.5×1015 ion/cm2), as well as 250 keV Bi ions (a surface dose of 1017 ion/cm2) and 250 keV Kr ions (a surface dose of 1016 ion/cm2), the pressure and temperature sensitivities of manganin foil have been investigated. It was found that the pressure sensitivity of manganin increased (α=2.45×10−5 MPa−1 before implantation and αimp=4.60×10−5 MPa−1 after complex implantation with 250 keV of Bi and Kr ions, the accuracy of estimation does not exceed 0.01×10−5 MPa−1) and its temperature sensitivity remained appreciably reduced.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Diamond and Carbon-based Materials Research · Ion-surface interactions and analysis · Polymer Nanocomposite Synthesis and Irradiation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (3)

Show source-provided references
1. Słowiński B, Wiśniewski R. JINR Comm E14-89, 512: 1-6, Dubna 1989.
2. Słowiński · Nukleonika · 1999 · 44 · 227
3. Wilczyńska · Vacuum · 2005 · 78 · 51510.1016/j.vacuum.2005.01.077 ↗