journal article·2002-01

Wall conditioning of TJ-II stellarator by glow discharge

D Tafalla

Vacuum· Volume 64· Issue 3-4
Publisher page

Abstract

Abstract The wall conditioning of the vacuum vessel has been a critical issue during the first experimental campaigns of TJ-II stellarator. In this paper, a new procedure for plasma density control in metallic wall scenarios, based on conventional glow discharge cleaning (GDC) techniques, is presented. After a first bakeout of the chamber, intensive He GDC at room temperature was applied with the aim of keeping the values of residual water as low as possible. A subsequent Ar GDC for 30 min before the TJ-II operation was required in order to remove an important fraction of He implanted on the wall, which hindered the density control in plasma discharges at injected powers above 300 kW. The Ar GDC removes a total amount of 10 21 He atoms from the TJ-II surface allowing a good control of plasma discharges. Detrapping cross sections for He atoms by Ar bombardment of 1.6×10 −15 cm 2 , for high coverages and 4×10 −16 cm 2 at lower ones were estimated.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnetic confinement fusion research · Plasma Diagnostics and Applications · Superconducting Materials and Applications