Electrons on a straight path: A novel ionisation vacuum gauge suitable as reference standard

Karl Jousten, Matthias Bernien, Frédéric Boineau, Nenad Bundaleski, Claus Illgen, Berthold Jenninger, Gustav Jönsson, Janez Šetina, Orlando M.N.D. Teodoro, Martin Vičar

Vacuum· Volume 189

Abstract

The consortium of the European project 16NRM05 designed a novel ionisation vacuum gauge in which the electrons take a straight path from the emitting cathode through the ionisation space into a Faraday cup. Compared to existing ionisation vacuum gauges, this has the advantage that the electron path length is well defined. It is independent of the point and angle of emission and is not affected by space charge around the collector. In addition, the electrons do not hit the anode where they can be reflected, generate secondary electrons or cause desorption of neutrals or ions. This design was chosen in order to develop a more stable ionisation vacuum gauge suitable as reference standard in the range of 10-6 Pa to 10-2 Pa for calibration purposes of other vacuum gauges and quadrupole mass spectrometers. Prototype gauges were produced by two different manufacturers and showed predictable sensitivities with a very small spread (< 1.5%), very good short-term repeatability (< 0.05%) and reproducibility (< 1%), even after changing the emission cathode and drop-down tests. These characteristics make the gauge also attractive for industrial applications, because a gauge exchange does not require calibration or re-adjustment of a process.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Plasma Diagnostics and Applications · Scientific Measurement and Uncertainty Evaluation · Electron and X-Ray Spectroscopy Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. ISO 27894:2009 Specifications for hot cathode ionization gauges.
2. A review on hot cathode ionisation gauges with focus on a suitable design for measurement accuracy and stability10.1016/j.vacuum.2020.109545 ↗
3. Stable and reproducible Bayard-Alpert ionisation gauge10.1116/1.578837 ↗
4. New x-ray limit measurements for extractor gauges10.1116/1.577192 ↗
5. Development of a design for an ionisation vacuum gauge suitable as a reference standard
6. New ionization gauge geometries providing stable and reproducible sensitivities10.1116/1.572714 ↗
7. An ionization gauge for measurement of Ultra-high vacua, Transact. of the 8th Nat
8. Stabilisierung der Empfindlichkeit von Heißkathoden-ionisationsvakuummetern
9. Influence of ion induced secondary electron emission on the stability of ionisation vacuum gauges, Vacuum
10. The effect of ambient temperature on the sensitivity of hot-cathode ionization gauges10.1016/j.vacuum.2004.09.013 ↗
11. Comparison of the Standards for high and ultrahigh vacuum at three national standard laboratories
12. Final report of key comparison CCM.P-K3: absolute pressure measurements in gas from 3 × 10-6 Pa to 9 × 10-4 Pa10.1088/0026-1394/47/1A/07004 ↗