NOx treatment by DC streamer corona discharge with series gap
Source abstract
Abstract
Abstract Among many methods used for removal of NO from flue gas, a positive DC streamer corona discharge method is presented in this paper. To generate a uniform streamer corona discharge, which is effective for the NO treatment, a series gap was connected to the main discharge reactor. The electrical and optical measurements showed that the series gap was useful for getting the uniform streamer discharge. Using the series gap, a voltage pulse whose d V /d t was from 0.7 to 2.72 kV/ns (depending on the series gap spacing) was produced in the main reactor. The energy consumption of the series gap was from about 6% to 20% of the total input power for different series gap spacings from 0.3 to 1.05 mm.The maximum NO removal rate of 90% was obtained at the main gap spacing of 30 mm and series gap spacing of 0.9 mm. Maximum removal efficiency of 6.0 g NO/kW h also occurred at a series gap spacing of 0.3 mm.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Plasma Applications and Diagnostics · Gas Sensing Nanomaterials and Sensors · Plasma Diagnostics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (5)
Show source-provided references
1. Yan · Trans IEE Japan · 1998 · 118-A · 948
2. Sigmond · 1978
3. Yan K, van Veldhuizen EM, Rea M, Li R, J Adv Oxid Technol 1998.
4. Gasparik · Vacuum · 2000 · 59 · 22010.1016/S0042-207X(00)00273-6 ↗
5. Guan P, Ihara S, Gasparik R, Yamabe C, Proceedings of the 1999 Joint Conference of Electrical and Electronics Engineers in Kyushu, Kitakyushu, p. 67.