journal article·2007-06

PIXE detection limits for dental enamel from some human teeth by excitation with protons and 4He2+ ions from a 3MeV Van der Graaff accelerator

C. Oprea, A.P. Kobzev, I.A. Oprea, P.J. Szalanski, V. Buzguta

Vacuum· Volume 81· Issue 10
Publisher page

Abstract

Abstract A technique has been developed to measure elemental content in human teeth using H+ and 4He2+ ion beam analysis. Teeth of Oradea inhabitants were sampled in two stomatological clinics in Oradea in the period of 2004 and 2005 years. Tooth samples were irradiated in vacuum with 2 MeV proton and 3 MeV alpha beams from a Van der Graaff electrostatic accelerator of EG-5 experimental facility in FLNP, JINR. The particle induced X-ray emission (PIXE) analysis, apart from determination of Ca, allowed an optimised detection of Cr, Cu, Fe and Zn above the detection limits by the use of Al and Mylar filters. The detection limits for Kα X-rays using proton and alpha beams are determined and discussed.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: X-ray Spectroscopy and Fluorescence Analysis · Nuclear Physics and Applications · Radiation Shielding Materials Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Carvalho · X-ray Spectrom · 2004 · 33 · 5510.1002/xrs.705 ↗
2. Bren · Nucl Instrum Methods B · 1999 · 158 · 27010.1016/S0168-583X(99)00305-5 ↗
3. Elias · Am J Phys Anthropol · 1980 · 53 · 110.1002/ajpa.1330530102 ↗
4. Elias · Geochim Cosmochim Acta · 1982 · 46 · 256110.1016/0016-7037(82)90378-7 ↗
5. Rheingold · J Chem Educ · 1983 · 60 · 23310.1021/ed060p233 ↗
6. Grunke · Fresenius J Anal Chem · 1996 · 354 · 63310.1007/s0021663540633 ↗
7. Solis · Nucl Instrum Methods B · 1996 · 118 · 35910.1016/0168-583X(95)01177-3 ↗
8. Lane · Biol Trace Elem Res · 1997 · 60 · 110.1007/BF02783305 ↗
9. Oprea · Environ Prog · 2005 · 3 · 273
10. Oprea · Rev Cytol Biol Vég · 2005 · 28 · 439
11. Cohen · Nucl Instrum Methods · 1981 · 188 · 20310.1016/0029-554X(81)90340-2 ↗
12. Rizzutto · Nucl Instrum Methods B · 2002 · 190 · 18610.1016/S0168-583X(01)01216-2 ↗
13. Andrade · Nucl Instrum Methods B · 1998 · 137 · 90810.1016/S0168-583X(97)00892-6 ↗
14. Lane · Nucl Instrum Methods B · 1996 · 118 · 39210.1016/0168-583X(95)01181-1 ↗
15. Pajek · Nucl Instrum Methods B · 1989 · 42 · 34610.1016/0168-583X(89)90446-1 ↗
16. Brudevold · 1967
17. Güereca G, Ruvalcaba-Sil JL. In: Proceedings of the 10th international conference on PIXE, its analysis and applications. Portorož, Slovenia, June 4–8, 2004. p. 825.1 〈http://pixe2004.ijs.si/〉.
18. Van Grieken RE, Markovicz AJ, editors. Handbook of X-ray spectrometry. Practical spectroscopy series, vol. 29. New York: 2002.10.1201/9780203908709 ↗
19. Chu · 1978
20. Johansson · Int J PIXE · 1992 · 2 · 3310.1142/S012908359200004X ↗
21. Beck · X-ray Spectrom · 2005 · 34 · 39310.1002/xrs.854 ↗
22. Zlokazov · Comput Phys Commun · 1982 · 28 · 2710.1016/0010-4655(82)90060-1 ↗
23. Grime · Nucl Instrum Methods B · 1996 · 109/110 · 17010.1016/0168-583X(95)00901-9 ↗
24. Bohac · Nucl Instrum Methods B · 1994 · 84 · 49710.1016/0168-583X(94)95344-9 ↗
25. Ahlberg · Int J Appl Radiat Isot · 1976 · 27 · 27910.1016/0020-708X(76)90145-9 ↗
26. Van Gysel · X-ray Spectrom · 2003 · 32 · 13910.1002/xrs.628 ↗
27. Papp · X-ray Spectrom · 2001 · 30 · 7710.1002/xrs.459 ↗
28. Pallon · Nucl Instrum Methods B · 2005 · 231 · 27410.1016/j.nimb.2005.01.070 ↗
29. Bennun · X-ray Spectrom · 2002 · 31 · 28910.1002/xrs.556 ↗
30. Orlic · Nucl Instrum Methods B · 2003 · 210 · 33010.1016/S0168-583X(03)01059-0 ↗
31. Svalbe · Nucl Instrum Methods B · 1984 · 3 · 64810.1016/0168-583X(84)90455-5 ↗