journal article·2008-02

Monitoring oxygen species in diamond hot-filament CVD by zircon dioxide sensors

J. Hirmke, S.M. Rosiwal, R.F. Singer

Vacuum· Volume 82· Issue 6
Publisher page

Abstract

Abstract Electrochemical zircon dioxide oxygen sensors were applied to measure oxygen in diamond hot-filament CVD (HFCVD) coating atmospheres. These low-pressure hydrogen environments are highly reductive and methane containing. Under industrial coating conditions there is the possibility that oxygen from ambient air enters the reactor by leakages. This leads to a tremendous influence on coating conditions by lowering the active carbon content in the gas phase and by decarburizing the gas activating filaments in HFCVD. In order to ensure process stability, a monitoring of an oxygen-related value is desired. This work displays the possibility to measure oxygen in HFCVD with potentiometric and amperometric ZrO 2 sensors. The dependency of the sensor signals on process parameters is investigated and the possibility of monitoring an oxygen-related value during a coating process is shown. The sensor signals allow a comparison of plants and processes regarding the seal tightness condition. The employed zircon dioxide sensors offer a cost effective and feasible method to monitor air leakage and ensure process reproducibility.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Diamond and Carbon-based Materials Research · Analytical Chemistry and Sensors · Advanced Sensor Technologies Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. Mankelevich · Diamond Relat Mater · 2002 · 11 · 56710.1016/S0925-9635(01)00557-X ↗
2. Smith · J Appl Phys · 2002 · 92 · 67210.1063/1.1481961 ↗
3. Peters H, Möbius H-H. DDR-Patent 21 673, angem. 20.5.1958, ausgeg. 7.8.1961.
4. ZIROX Sensoren & Elektronik GmbH Greifswald, 〈http://www.zirox.de/html/vacuumsonde.html〉.
5. Vakuum Forschung Praxis · 2003 · 15 · 217
6. Möbius H-H, Hartung R, Brunner E. DE Patentanmeldung Nr. 103 24 954.0, 3.6.2003.
7. ZIROX Sensoren & Elektronik GmbH Greifswald. DE Gebrauchsmusteranmeldung Nr. 203 15 483.5, 8.10.2003.
8. Hartung · J Anal Chem · 1996 · 356 · 228
9. Hartung · Fresenius J Anal Chem · 1994 · 349 · 57110.1007/BF00323459 ↗
10. Lang T. PhD thesis, Technische Universität Wien, Wien, 1993.
11. Ashfold · Phys Chem Chem Phys · 2001 · 3 · 347110.1039/b104265n ↗
12. Goodwin · J Appl Phys · 1990 · 68 · 639310.1063/1.346858 ↗
13. Mankelevich · Diamond Relat Mater · 1998 · 7 · 113310.1016/S0925-9635(98)00163-0 ↗
14. Mankelevich · 2001
15. Sommer · J Vac Sci Technol · 1991 · A910.1116/1.577590 ↗
16. Harris · Appl Phys Lett · 1989 · 55 · 217910.1063/1.102350 ↗
17. Ullman · 1992
18. Göpel W, Jones TA, Kleitz M, Lundström I, Seiyama T, editors. Sensors Volume 2: Chemical and biochemical sensors—Part I, A comprehensive survey. Weilheim: Wiley VCH; 1991, 1.Auflage.
19. Reiter W. Diploma thesis, Technische Universität Wien, Wien, 1997.
20. Hartung · Z Phys Chem · 1985 · 266 · 113510.1515/zpch-1985-266137 ↗
21. Rüffer M. Diploma thesis. University of Erlangen, Nuremberg, 1999.