Arc Parameters in CO2-blast quenching chamber with high-pressure storage tank of different pressures
Source abstract
Abstract
Abstract The present paper reports CO 2 arc parameters just before a current-zero measured for a double-pressure type interrupting apparatus. The arc parameters before a current-zero were determined at the CO 2 pressure in a high-pressure storage tank of 0.2–0.6 MPa. The increase in the high-pressure storage tank from 0.2 to 0.6 MPa raises the arc power loss from 0.32 to 0.78 kW and also decreases the arc time constant from 1.3 to 0.7 μs for a current with a peak value of 1.1 kA. On the basis of the measured arc parameters, the increase in an interrupting capability of the apparatus with the CO 2 pressure was discussed. As a result, it was concluded that this increase in the interrupting capability resulted from the decrease in the arc time constant.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Vacuum and Plasma Arcs · Combustion and Detonation Processes · Electrical Fault Detection and Protection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (4)
Show source-provided references
1. Approach to Decaying Process of Arc Conductance after Current Zero on the basis of Thermodynamic and Transport Properties of High Temperature Gases
2. Inoue K, et al. Arc Interrupting Capability of a Puffer-Type Load Break Switch using Environmentally Benign Gases. In: Proceedings of the fifteenth annual conference of power & energy society. IEE of Japan, No. 155, 2004 (in Japanese).
3. Yokomizu Y, et al. Time Constants and Conductances of Wall-Stabilized Arcs Burning in Different Gases. Proceedings of the international workshop on high voltage engineering (IWHV’00), vol. 1, Tottori, Japan, 2000. pp.7–12.