Abstract The Heavy Ion Medical Machine (HIMM) is the first medical accelerator being built in China using heavy ion beams for cancer therapy. The accelerator complex, developed by IMP (the Institute of Modern Physics, Chinese Academy of Sciences), has several innovative features, including the use of a synchrotron ring as the main ion accelerator. To guarantee a sufficient storage lifetime of the heavy ions, the average pressure for the entire synchrotron ring must be lower than 5 × 10 −7 Pa. This has been achieved integrating a sputter ion and a NEG pump in a suitably designed combination pump. The compact size of the combination pump (CP) allows its easy mounting in spite of the severe space limitations of the machine. The overall CP pumping speed exceeds 1000 l/s (H 2 ), a factor 2 larger than a standard ion pump of comparable size. This feature allows achieving lower ultimate pressure in shorter time, this being beneficial to increase the beam time for patient treatment at HIMM. The CP was also tested under very high gas loads to assess its usability at higher pressure (10 −5 –10 −6 Pa). Preliminary data indicate that long term stable pumping performances of the CP can be achieved also under these more demanding conditions. The result is of more general interest for compact accelerators operating in this pressure range and requiring very compact pump design solutions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Radiation Therapy and Dosimetry · Particle accelerators and beam dynamics · Radiation Effects in Electronics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Effectiveness of monoenergetic and spread-out Bragg peak carbon-ions for inactivation of various normal and tumour human cell lines10.1269/jrr.08052 ↗
2. Review of Hadron therapy accelerators worldwide and future trends
3. Slow extraction design in HIMM
4. A new ultrahigh vacuum combination pump10.1116/1.574390 ↗
5. Combined sputter ion and NEG pump10.1016/0042-207X(92)90075-8 ↗
6. The vacuum system for Shanghai synchrotron radiation facility (SSRF)10.3131/jvsj.49.754 ↗
7. Combination of compact non evaporable getter and small ion pumps for ultra- high vacuum systems10.1116/1.3529379 ↗
8. Vacuum tracking
9. www.saesgetters.com.
10. Monte Carlo computations on molecular flow in pumping speed test domes10.1016/0042-207X(67)92176-8 ↗
11. Med-Austron beam vacuum system : from sources to patient treatment rooms
12. An X-ray photoemission spectroscopy investigation of thermal activation induced changes in surface composition and chemical bonds of two gettering alloys: Zr2Fe versus Zr57V36Fe710.1116/1.577518 ↗
13. Pumping characteristics of the St707 nonevaporable getter (Zr70 V24.6-Fe5.4)10.1116/1.580226 ↗
14. Room temperature pumping characteristics for gas mixtures of a Zr–Al nonevaporable getter10.1116/1.576460 ↗
15. Theory of bulk gettering10.1063/1.332477 ↗