journal article·2016-12

Outgassing analysis of the 14-m-long arc-cell vacuum chambers of the Taiwan Photon Source

L.H. Wu, T.Y. Lee, C.H. Chang, Y.C. Yang, C.S. Huang, Y.T. Huang, C.C. Chang, C.K. Chan, C.M. Cheng, S.N. Hsu, H.P. Hsueh, G.Y. Hsiung, J.R. Chen

Vacuum· Volume 134
Publisher page

Abstract

Abstract An overall outgassing analysis of the large, 14-m-long, ultra-high-vacuum aluminum arc-cell chambers of the Taiwan Photon Source (TPS) was performed using residual gas analyzer (RGA). Pumping primarily by ion pumps (IP) and non-evaporable getter (NEG) pumps, the cells obtained pressures of 6.4 × 10 −9 Pa on average, and the main residual gas was H 2 . The pressure build-up method was adopted to investigate the outgassing of the vacuum chambers. Because active gases (H 2 , CO, CO 2 ) were primarily pumped by NEG pumps, the increased vacuum pressure here mainly resulted from the inert gas. Therefore, the residual gases measured after switched off the ion pumps were CH 4 and Ar. After the ion pumps were baked separately, the outgassing of CH 4 was considerably diminished and the lowest achievable vacuum pressure was improved. The outgassing of Ar was primarily responsible for the long-term pressure build-up. Moreover, vacuum pressure measurements and residual gas analyses were performed in situ while a cell chamber was being transported. The vibration of the arc-cell vacuum chamber caused the pressure to rise abruptly; in this case, the outgassing gas measured during transportation was CH 4 . Once the arc cell was installed, the original level recovered because of the pumping effect of the ion gauges.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Atomic and Subatomic Physics Research · Scientific Measurement and Uncertainty Evaluation · Advancements in Photolithography Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. Design concept of the vacuum system for the 3 GeV taiwan photon Source
2. Comparison of chemical cleaning methods of aluminum alloy vacuum chambers for electron storage rings10.1116/1.575736 ↗
3. Surface analysis of carbon on ozone treated metals10.1116/1.579776 ↗
4. Stable performance of 508-MHz superconducting RF cavities for KEK B-Factory
5. Cleaning of aluminium alloy chambers with ozonized water10.1088/1742-6596/100/9/092025 ↗
6. Study of the ultra-high -vacuum system of the 14-m-long vacuum chamber of the Taiwan Photon Source using the pressure build-up method10.1016/j.vacuum.2014.06.015 ↗
7. Weissler · 1979
8. A. G. Mathewson, Vacuum System Design, CERN. Geneva, Switzerland.
9. Comparison of hot cathode and cold cathode ionization gauges10.1116/1.577439 ↗
10. On the effect of bakeout for the pumping speed dependence of outgassing rate in a stainless steel chamber10.1016/0042-207X(96)00059-0 ↗
11. O'Hanlon · 2003
12. Reduction in hydrogen outgassing from stainless steels by a medium-temperature heat treatment10.1116/1.2956625 ↗
13. Outgassing reduction of type 304 stainless steel by surface oxidation in air10.1116/1.579777 ↗
14. Outgassing characteristics of stainless steel and aluminum with different surface treatments10.1116/1.1492700 ↗
15. Desorption of the NEG-coated aluminum chamber10.1063/1.3120008 ↗
16. Outgassing of stainless steel during sliding friction in ultra-high vacuum10.1016/S0042-207X(98)00366-2 ↗
17. David Orálek, Outgassing stimulated by deformation10.1016/S0042-207X(98)00367-4 ↗
18. Comparison of some metrological characteristics of hot and cold cathode ionisation gauges10.1016/S0042-207X(02)00781-9 ↗