Study on the variation of the arc area in vacuum DC interruption
Source abstract
Abstract
Abstract The variation of the arc area in DC interruption was investigated. By the use of the vacuum interrupter with glass shielded, DC interruptions were carried out to obverse the arc appearance in the situation of axial magnetic. Meanwhile, using the CMOS high speed camera, arc images were obtained under the conditions of different commutation frequency, arcing time and pre-charged capacitor voltage. Subsequently, the arc area was obtained through the image processing technology. According to the obtained arc area, the factors influencing on the arc area were investigated, including the commutation frequency, arcing time and pre-charged voltage. The results indicated that the duration time of the commutation stage became shorter and the arc area decreased with the increase of commutation frequency. The rise rate of arc area in initial stage and the drop rate of arc area in commutation stage present the same trend under different arcing time. Considering the experimental results in this paper, arcing time of 2 ms is better for DC interruption. High pre-charged capacitor voltage leads to the increase of the current going through load. The capacitor voltage can be charged a little higher than the rated value for the reliable interruption of DC current.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Vacuum and Plasma Arcs · Electrical Fault Detection and Protection · Electrostatic Discharge in Electronics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Theory and application of the commutation principle for HVDC circuit breaker10.1109/TPAS.1972.293310 ↗
2. Ion parameters after forced extinguishing of the diffuse vacuum arc10.1109/TPS.2009.2024746 ↗
3. DC interruption characteristic of vacuum circuit breaker10.1002/eej.20362 ↗
4. Investigation on DC interruption based on artificial current zero of vacuum switch
5. Vacuum arc characters research on DC forcing interruption
6. Experimental investigation of the initial expansion process in a drawn vacuum arc and the influence of axial magnetic field10.1109/TPS.2011.2176963 ↗
7. Experimental investigation on the characteristics of drawn vacuum arc in initial expanding stage and in forced current-zero stage10.1109/TPS.2011.2131688 ↗
8. Insulation optimization by electrode contour modification based on breakdown area/volume effects10.1109/94.919913 ↗
9. High-speed imaging and radiative energy measurements of a high-current pulsed arc in air10.1109/TPS.2011.2116043 ↗
10. Investigation of multiphase AC arc behavior by high-speed video observation10.1109/TPS.2011.2149545 ↗
11. Research on arc burning and contact bounce of DC relays by high speed photograph method
12. Anode modes in vacuum arcs: Update10.1109/TPS.2017.2708695 ↗
13. D. Feng, S. Xiu, Y. Wang, G. Liu, Y. Zhang, D. Bi, Influence of axial self-magnetic field component on arcing behavior of spiral-shaped contacts, Phys. Plasmas, vol. 22, no. 10, 103505.10.1063/1.4933003 ↗
14. Experimental investigation on transition characteristics of arcing stages under transverse magnetic field10.1109/TPS.2018.2795021 ↗
15. HVDC vacuum circuit breaker10.1109/TPAS.1972.293311 ↗
16. The basic investigation of the high-speed VCB and its application for the DC power system
17. High-speed observations of arc modes and material erosion on RMF-and AMF-contact electrodes10.1109/TPS.2005.856514 ↗
18. Transition to the diffuse mode for high-current drawn arcs in vacuum with an axial magnetic field10.1109/TPS.2003.818416 ↗
19. Influence of the contact opening speed on DC vacuum arc10.1109/TPS.2015.2390256 ↗
20. Recovery of dielectric strength after DC interruption in vacuum10.1109/TDEI.2015.005167 ↗
21. Numerical investigation on residual axial magnetic field in vacuum interrupter in DC interruption based on artificial current zero10.1109/TPWRD.2016.2578981 ↗
22. Forced commutation performance of vacuum switches for HVDC breaker application10.1109/TPAS.1982.317643 ↗