journal article·2014-11

Comparison of spatial distributions of atomic oxygen and hydrogen in ICP by means of catalytic probes and actinometry

Z. Kregar, R. Zaplotnik, M. Mozetič, S. Milošević

Vacuum· Volume 109
Publisher page

Abstract

Low pressure inductively coupled plasma was investigated with a combination of two diagnostic techniques: catalytic probes and optical emission spectroscopy (actinometry). Three working gases were used: oxygen, oxygen–argon mixture and hydrogen. Concentrations of oxygen and hydrogen atoms were determined in a wide range of plasma parameters, with pressure ranging from 10 Pa to 70 Pa, applied power in the range from 50 to 250 W and at many different positions throughout the system (including the coil and afterglow in sample chamber). Concentrations of oxygen atoms were measured to be 1.3 × 1015 cm−3 in the middle of the coil and 4 × 1012 cm−3 in the regions of the chamber furthest from the coil. These spatially resolved concentrations are very important in plasma processing of materials, because radical concentrations over the sample determine plasma–material interactions. This work demonstrates that a relatively simple detection system can be practical and sufficiently successful in many plasma applications.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Plasma Applications and Diagnostics · Plasma Diagnostics and Applications · Analytical chemistry methods development

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. The emerging role of reactive oxygen and nitrogen species in redox biology and some implications for plasma applications to medicine and biology10.1088/0022-3727/45/26/263001 ↗
2. Studies of pure and nitrogen-incorporated hydrogenated amorphous carbon thin films and their possible application for amorphous silicon solar cells10.1063/1.3675164 ↗
3. Surface modification and ageing of PMMA polymer by oxygen plasma treatment10.1016/j.vacuum.2011.07.005 ↗
4. Plasma applications: a dermatological view10.1002/ctpp.201310061 ↗
5. Characterization of bacillus subtilis spore inactivation in low-pressure, low-temperature gas plasma sterilization processes10.1111/j.1365-2672.2009.04453.x ↗
6. Sterilization of food contacting surfaces via non-thermal plasma treatment: a model study with Escherichia coli-contaminated stainless steel and polyethylene surfaces10.1007/s11947-012-1007-2 ↗
7. Low-temperature, low-pressure gas plasma application on aspergillus brasiliensis, Escherichia coli and pistachios10.1111/jam.12448 ↗
8. Spectroscopic measurements of nonequilibrium CO2 plasma in RF torch10.1016/j.chemphys.2008.09.006 ↗
9. Monitoring oxygen plasma treatment of polypropylene with optical emission spectroscopy10.1109/TPS.2011.2123111 ↗
10. Plasma-cavity ringdown spectroscopy for analytical measurement: progress and prospectives10.1016/j.sab.2013.04.007 ↗
11. Expansion and backscattering of laser produced Fe plasma plume10.1016/j.sab.2012.01.010 ↗
12. Application of Langmuir probe in recombination dominated afterglow plasma10.1002/ctpp.200810084 ↗
13. Electron energy distribution function measurements and plasma parameters in inductively coupled argon plasma10.1088/0963-0252/11/4/320 ↗
14. Hairpin resonator probe measurements in RF plasmas10.1088/0963-0252/14/4/012 ↗
15. A fiber optic catalytic sensor for neutral atom measurements in oxygen plasma10.3390/s120403857 ↗
16. The 2012 plasma roadmap10.1088/0022-3727/45/25/253001 ↗
17. Comparison of TALIF and catalytic probes for the determination of nitrogen atom density in a nitrogen plasma afterglow10.1088/0022-3727/42/5/055204 ↗
18. Comparison of NO titration and fiber optics catalytic probes for determination of neutral oxygen atom concentration in plasmas and postglows10.1116/1.1539082 ↗
19. Characterization and global modelling of low-pressure hydrogen-based RF plasmas suitable for surface cleaning processes10.1088/0022-3727/46/47/475206 ↗
20. Space and time resolved optical emission spectroscopy characterization of inductively coupled RF water vapour plasma10.1088/0022-3727/42/14/145201 ↗
21. Comparison of fiber optics and standard nickel catalytic probes for determination of neutral oxygen atoms concentration10.1116/1.1427893 ↗
22. Determination of atomic oxygen density with a nickel catalytic probe10.1116/1.582189 ↗
23. Recombination of neutral hydrogen atoms on AISI 304 stainless steel surface10.1016/S0169-4332(98)00830-7 ↗
24. Time resolved spectroscopic characterization of A–C: H deposition by methane and removal by oxygen inductively coupled RF plasma10.1007/s11090-010-9226-7 ↗
25. Inductively coupled RF oxygen plasma studied by spatially resolved optical emission spectroscopy10.1109/TPS.2008.920896 ↗
26. Studies of atomic oxygen in O-2+CF4 RF discharges by 2-photon laser-induced fluorescence and optical-emission spectroscopy
27. Oxygen plasma functionalization of poly (p-phenilene sulphide)10.1016/j.apsusc.2007.04.074 ↗
28. Characterization of extremely weakly ionized hydrogen plasma with a double Langmuir probe
29. Detection of atomic oxygen: improvement of actinometry and comparison with laser spectroscopy10.1063/1.1315332 ↗