Process-induced oscillator frequency pulling and phase noise within plasma systems
Source abstract
Abstract
Abstract Passive radio spectroscopy is employed to examine plasma process instabilities generated by the interaction between the power source oscillator and the plasma load. A fixed frequency of 13.56 MHz and a 170–180 kHz Flyback transformer are considered. The carrier frequencies are interrogated using a resolution bandwidth that constitutes ∼1/7000–1/580 of the target oscillator frequencies with a sweep time of less than 0.06 s across the phase noise disturbance. Within these spectrum analyzer measurement parameters, oscillator phase noise (1/ f n= 1–3 , discrete spurs and raised noise floor) is shown to be linked to plasma load mismatch and periodic instabilities. In the case of the Flyback circuit, it is found that the oscillator frequency pulling and modulation are linked to the plasma reactance. These results indicate that oscillator phase noise can be used as a non-invasive plasma process metrology tool.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Acoustic Wave Resonator Technologies · Advanced Frequency and Time Standards · Advanced Electrical Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Passive radio spectroscopy of atmospheric plasma10.1049/el:20060293 ↗
2. Brouk V, Heckman R. Stabilizing RF generator and plasma interactions. 47th (SVC) annual conference proceedings 49–54, 2005 [ISSN 0737-5921].
3. Instabilities in inductively coupled oxygen plasma10.1088/0963-0252/12/2/318 ↗
4. Chlorine plasma system instabilities within an ICP driven at a frequency of 13.56MHz10.1088/0963-0252/15/2/004 ↗
5. Harmonic monitoring of the switched silicon etch process10.1088/0022-3727/36/17/319 ↗
6. Process harmonic pulling in a RIE plasma-tool10.1049/el:20064133 ↗
7. Oscillator phase noise: a tutorial10.1109/4.826814 ↗
8. A comparison of flicker noise and shot noise on a hot cathode10.1109/27.887726 ↗
9. 1999
10. Fault detection for a via etch process using adaptive multivariate methods10.1109/TSM.2005.858495 ↗
11. Atmospheric pressure DBD gun and its application in ink printability10.1088/0963-0252/14/4/005 ↗
12. Electrical and optical characterisation of the plasma needle10.1088/1367-2630/6/1/149 ↗
13. Measurement of levels of non-ionising radiation emitted by a glow discharge display globe10.1088/0952-4746/10/1/005 ↗
14. Information on the National Instrument sound and vibration toolkit 5.0 for LabVIEW 8.2 can be found at 〈www.ni.com〉.