Cylindrical hot cathode ionisation gauge – The concept and simulations
Source abstract
Abstract
A novel design of an ionisation vacuum gauge is presented, aiming to achieve predictable sensitivity and high accuracy in high and the ultra-high vacuum range. The proposed design features a belt-like electron beam emitted from a linear filament, following a circular trajectory between two cylindrical electrodes, resembling a cylindrical analyser. The proposed design offers several key upsides: a precisely defined electron beam trajectory with reduced susceptibility to path variations, effective electron collection in a Faraday cup able to contain secondary emissions and backscattered electrons, and the inclusion of a suppressor grid in front of the ion collector to eliminate ion-induced secondary electron emission. These features are expected to secure high stability of the gauge and the low pressure limit. An in-depth description of the design is presented, along with the discussions on simulations of the key components that provide the improved performance.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Scientific Measurement and Uncertainty Evaluation · Radioactive Decay and Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. Vacuum metrology and its impact on research and industry: from state of the art measurements to future trends10.1002/vipr.201900715 ↗
2. Sensitivity of hot cathode ionization gages10.1116/1.572991 ↗
3. Comparison of some metrological characteristics of hot and cold cathode ionisation gauges10.1016/S0042-207X(02)00781-9 ↗
4. Nonstable behavior of widely used ionization gauges10.1116/1.578835 ↗
5. Long-term stability of metal-envelope enclosed Bayard–Alpert ionization gauges10.1116/1.4750482 ↗
6. The spinning rotor gauge10.1116/1.573007 ↗
7. Precise quantum measurement of vacuum with cold atoms10.1063/5.0120500 ↗
8. Comparison of two multiplexed portable cold-atom vacuum standards10.1116/5.0095011 ↗
9. Numerical investigations of hot cathode ionization gauges10.1016/S0042-207X(98)00133-X ↗
10. 3D-simulation of ionisation gauges and comparison with measurements10.1016/j.vacuum.2016.12.014 ↗
11. Effect of the magnetic field on the operation of ionisation gauges10.1016/j.vacuum.2022.111339 ↗
12. 3D-Simulation of a Bayard Alpert ionisation gauge using SIMION program10.1016/j.vacuum.2019.03.039 ↗
13. Development of a design for an ionisation vacuum gauge suitable as a reference standard10.1016/j.vacuum.2020.109884 ↗
14. Novel ionisation vacuum gauge suitable as a reference standard: influence of primary electron trajectories on the operation10.1016/j.vacuum.2022.111041 ↗
15. Evaluation and metrological performance of a novel ionisation vacuum gauge suitable as reference standard10.1016/j.measurement.2023.112552 ↗
16. A cylindrical triode ultrahigh vacuum ionization gauge with a carbon nanotube cathode
17. Investigation of a spherical oscillator ionization gauges with carbon nanotube field-emitter cathodes
18. Simulation of bayard alpert ionization vacuum gauge with COMSOL
19. Numerical simulation of the performance of the ASDEX pressure gauge10.1016/j.vacuum.2021.110237 ↗
20. Numerical simulation of relative sensitivity factor of Bayard–Alpert gauge10.1016/j.vacuum.2020.109525 ↗
21. Tegerup · 2018
22. New hot-filament ionization gauge with low residual current10.1116/1.1492470 ↗
23. Ion gauge for vacuum pressure measurements below 1×10−10 torr10.1063/1.1720076 ↗
24. Axial-symmetric transmission gauge: extension of its pressure measuring range and reduction of the electron stimulated desorption ion effect in ultrahigh vacuum10.1116/1.1901668 ↗
25. Ion spectroscopy gauge: total pressure measurements down to 10 −12 Pa with discrimination against electron‐stimulated‐desorption ions10.1116/1.577821 ↗
26. Bent belt-beam gauge: extending low-pressure measurement limits in a hot-cathode ionization vacuum gauge by combining multiple methods10.1116/1.3400233 ↗
27. Electrons on a straight path: a novel ionisation vacuum gauge suitable as reference standard10.1016/j.vacuum.2021.110239 ↗
28. Traceable low-current measurements for a novel ionization gauge suitable as reference standard
29. Electron trajectories in ionization gauges10.1088/0022-3727/3/7/316 ↗
30. Dependence of sensitivity coefficient of a nude-type Bayard-Alpert gauge on the diameter of an envelope10.1016/S0042-207X(98)00353-4 ↗
31. Causes of nonstability and nonreproducibility in widely used Bayard–Alpert ionization gauges10.1116/1.578836 ↗
32. An ionization gauge for measurement of ultra-high vacuum
33. On the analysis of electronic velocities by electrostatic means10.1103/PhysRev.34.284 ↗
34. Stable and reproducible Bayard-Alpert ionisation gauge10.1116/1.578837 ↗
35. Extension of the low pressure range of the ionization gauge10.1063/1.1745653 ↗
36. Surface effects on the stability of hot cathode ionization gauges10.1016/0042-207X(88)90173-X ↗
37. Influence of ion induced secondary electron emission on the stability of ionisation vacuum gauges10.1016/j.vacuum.2020.109907 ↗
38. New x‐ray limit measurements for extractor gauges10.1116/1.577192 ↗
39. New model for electron-impact ionization cross sections of molecules10.1063/1.471116 ↗
40. CASINO V2.42 - a fast and easy-to-use modeling tool for scanning electron microscopy and microanalysis users10.1002/sca.20000 ↗
41. Measuring the angular dependent energy distribution of backscattered electrons at variable geometry10.1002/sca.4950270605 ↗
42. Sensitivity reduction and restoration in an extractor gauge10.1016/0042-207X(96)00021-8 ↗
43. Secondary electron emission in the scanning electron microscope10.1063/1.332840 ↗
44. Fliigge · 1992