High-voltage pulse bushing with induced voltage distribution between sections
Source abstract
Abstract
Abstract The article presents test results of a sectioned vacuum bushing with induced voltage distribution. The bushing was tested with voltage pulses with amplitudes of 24 and 90 kV. The setting of the voltage along the gradient rings was carried out using a galvanic coupling with the turns of a high-voltage pulse transformer. The presented method has allowed distributing the applied voltage between the sections with a deviation of less than 3.5% from the uniform distribution throughout the entire pulse duration (0.25 μs FWHM). The tests with 90 kV pulses were carried out at a pressure of 10−4 Тоrr. The conical design of the bushing provided a decrease in the average electric field strength in vacuum insulating gaps and a higher rate of the residual atmosphere pumping out, as compared to the traditional cylindrical design of pulse vacuum bushings. The investigated bushing can be used in designs of vacuum electron diodes of pulsed accelerating systems.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Pulsed Power Technology Applications · Gyrotron and Vacuum Electronics Research · Vacuum and Plasma Arcs
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Electric breakdown in solid dielectrics10.1007/BF00890544 ↗
2. Experimental analysis on electrical breakdown of acrylic VHB tape under quasi-static and pulsed voltage10.1134/S1063784218010231 ↗
3. Flashover of insulators in vacuum: review of the phenomena and techniques to improved holdoff voltage10.1109/14.231534 ↗
4. Kotov · 1986
5. Flashover of insulators in vacuum: the last twenty years10.1109/TDEI.2015.004702 ↗
6. Comparison of influence of gamma rays and E-beam on some chloramphenicol derivatives10.2174/157341112801264941 ↗
7. Direct comparison of gamma, electron beam and X-ray irradiation effects on single-use blood collection devices with plastic components10.1016/j.radphyschem.2020.109282 ↗
8. The Astra repetitive-pulse electron accelerator10.1134/S0020441213050035 ↗
9. Submicrosecond electron accelerator based on pulsed transformer
10. Self-bearing membrane exit window with the separate anode for sub-microsecond electron accelerator10.1016/j.vacuum.2019.109111 ↗
11. Repetitive nanosecond electron accelerators type URT-1 for radiation technology10.1016/j.radphyschem.2017.08.023 ↗
12. High power electron accelerators of ELV-series: status, development, applications, Radiat
13. A vacuum feedthrough insulator at a voltage of ∼1 MV10.1023/A:1026041705575 ↗
14. Characteristics of plasma process in explosive electron emission
15. Experimental research of different plasma cathodes for generation of high-current electron beams10.1063/1.4935880 ↗
16. Subnanosecond electron beams formed in a gas-filled diode at high pressures10.1134/1.1813732 ↗
17. Experimental demonstration of a single capillary, water-activated cathode for a sub-microsecond electron accelerator10.1016/j.nima.2019.162459 ↗
18. Note: numerical simulation and experimental validation of accelerating voltage formation for a pulsed electron accelerator10.1063/1.4884895 ↗
19. Low-inductive accelerating tube for heavy-current electron-accelerators
20. A new concept of a vacuum insulation tandem accelerator10.1016/j.apradiso.2015.06.015 ↗
21. Yoshimura · 2008
22. Discrete liquid-helium level-meter sensors based on TVO carbon resistors10.1134/S0020441214030014 ↗
23. Coaxial capacitive dividers for high-voltage pulse measurements in intense electron beam accelerator with water pulse-forming line10.1109/TIM.2008.927195 ↗
24. High-speed surface temperature measurement in Ti-coated aluminum during electron beam irradiation
25. A picosecond risetime high voltage divider10.1063/1.1686773 ↗
26. Aqueous-solution high-voltage resistors: development, study, and application (review)10.1134/S0020441206010015 ↗
27. Cryo-torr 8, Brooks Automation, https://www.brooks.com/products/cryopumps-cryochillers/cryopumps/cryo-torr-cryopumps, (n.d).
28. Televac CC-10 Wide Range Gauge, Fredericks Company, https://www.frederickscompany.com/products/cc-10-wide-range/, (n.d).
29. Immitance meter E7-21, http://en.mnipi.by/catalog/izmeriteli-immitansa-rlc/izmeritel-immitansa-e7-21.html, (n.d).