Development and test of a multi-target transmission X-ray tube based on the electron deflection in an electric field
Source abstract
Abstract
Abstract The multitarget X-ray tube has special advantage for the X-ray fluorescence analysis of complex sample. The current paper reports on a four-target transmission X-ray tube based on the electron deflection in an electric field. It consists of four 90° sector targets, which are Cr, Ni, Au, Mo. The electron trajectory is selectively bent by the deflection field to bombard the desired target. The emission spectrum was detected by the silicon drift detector (SDD) at 1.1 W (−22 kV, 50 μA). The results showed the characteristic X-rays of the corresponding target produced clearly, especially for the Cr or Au target with a high intensity. The focal spot size was tested using the pinhole camera method. The results showed the electrons were bent effectively, the corrected area of real focal spot was between about 4 mm2 to 9 mm2. This multitarget X-ray tube will provide the selective X-ray spectrum of the application for the sample analysis.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Nuclear Physics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Hershyn · 1989
2. Note: development of target changeable palm-top pyroelectric x-ray tube10.1063/1.3677843 ↗
3. Development of a micro-focus x-ray fluorescence spectrometer using multiple target anode monochromatic x-ray sources10.1002/xrs.1168 ↗
4. Development of an X-ray tube with two selective targets modulated by a magnetic field10.1063/1.5094914 ↗
5. Energy-selective reconstructions in X-ray computerized tomography10.1088/0031-9155/21/5/002 ↗
6. Novel multi-energy X-ray imaging methods: experimental results of new image processing techniques to improve material separation in computed tomography and direct radiography10.1371/journal.pone.0232403 ↗
7. An optimal design of X-ray target for uniform X-ray emission from an electronic brachytherapy system10.1016/j.nimb.2011.03.001 ↗
8. Respective radiation output characteristics of transmission-target and reflection-target X-ray tubes with the same beam quality10.1016/j.radphyschem.2019.02.005 ↗
9. Optimization of X-ray target parameters for a high-brightness microfocus X-ray tube10.1016/j.nimb.2007.09.023 ↗
10. A microfocus X-ray tube based on a microstructured X-ray target10.1016/j.nimb.2009.08.012 ↗
11. A design of transmission-type multi-target X-ray tube based on electric field modulation10.1016/j.net.2021.03.002 ↗
12. Equipment design and performance characterization of full field x-ray fluorescence (FF-XRF) element distribution imaging system with combined collimating lens (CCL)10.1063/5.0024461 ↗
13. Focal-spot measurement comparison of slit, pinhole, and star resolution pattern techniques10.1148/radiology.165.1.3628780 ↗
14. Electron backscatter in X-ray tubes: experiment and analysis