Faraday Cup for high current and duty cycle electron LINACs
Source abstract
Abstract
Abstract The design of a Faraday Cup (FC) is presented. The FC is designed to be used at an industrial LINAC test beamline. The present study gives the comprehensive design of FC to minimize the effects of secondary electrons. It also describes the heat dissipation at collector and its cooling design. A 200 mm long FC with aperture diameter of 20 mm and back wall thickness of 30 mm with repeller ring is simulated in CST particle studio software. A repeller ring is optimized for its thickness and axial distance to minimize the escape percentage of secondary charges from FC. The change in the thickness of repeller ring, axial distance and barrier potential greatly influence the escaped percentage. The study incorporates the secondary electron source at back wall of FC with fixed emission of 1.5 × 104 particles having energy 500 eV (10% dispersion) with different angular spread i.e. 0°, 45°, 90°. The escape percentage less than 1% is observed for 7 mm repeller ring-FC distance and 3 mm thickness with barrier potential of −700 V. The optimized design of the repeller ring reduces the physical dimensions of the FC. Moreover, the study also presents the mechanical design and heat transport analysis of Faraday cup. The designed square type channels with water circulating at 20 L/min limits the temperature to 333 K at the surface of the FC. Initial experimental results for thermal design are also presented, showing that temperature rise under 6 MeV, 4 μsec pulse width and 100 Hz repetition rate; is limited to 304 K. The cooling efficiently mitigates the heat load at water flow rate of 7.5 L/min.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Gyrotron and Vacuum Electronics Research · Particle accelerators and beam dynamics · Plasma Diagnostics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Tutorial on beam current monitoring
2. Surface and electro-luminescence characterization of Cerium doped Yttrium Aluminium Garnet produced by spray and electrophoretic deposition techniques10.1016/j.surfin.2018.02.008 ↗
3. Faraday cup monitors for high energy electron beams10.1063/1.1715674 ↗
4. Mcchesney · 2009
5. Strehl · 2006
6. A technique for accurate measurements of ion beam current density using a Faraday cup10.1063/1.1287635 ↗
7. Electron beam characterisation methods and devices for welding equipment10.1016/j.jmatprotec.2015.02.024 ↗
8. Design of a compact Faraday cup for low energy, low intensity ion beams10.1016/j.nima.2015.09.096 ↗
9. Development of multi Faraday cup assembly for ion beam measurements from a low energy plasma focus device10.1143/JJAP.44.5199 ↗
10. Design and study of an enhanced Faraday cup detector10.1016/j.vacuum.2009.01.005 ↗
11. L. M. Young, "PARMELA," Los Alamos National Laboratory Report, LA-UR-96-1835 (Revised February 27, 2001).
12. Cengel · 2011
13. Bravin · 2014
14. Design and characterization of a versatile Faraday cup10.1063/1.1144216 ↗
15. Design and simulation of a new Faraday Cup for ES-200 electrostatic accelerator
16. Introduction to health physics: fourth edition10.1118/1.3021454 ↗
17. Hasselkamp · 1992