Elettra vacuum system: status and experience with the new Al vacuum chambers
Source abstract
Abstract
The status and recent developments of the Elettra vacuum system are reported. Due to the fact that in our facility no in-situ bake out is applied, we focused our work to contribute to the theoretical explanation of the beam cleaning efficiency. Gas injection experiments have been performed introducing various gases into the vacuum chamber of the storage ring. These experiments are very useful and help us to analyse better behaviour of vacuum chambers having a higher pressure profile. New aluminium vacuum chambers have been recently installed into the storage ring. Operational experience is also reported.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Laser Design and Applications · Advanced Frequency and Time Standards
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Karantzoulis E, Miertusova J, Vascotto A. Proceedings of the PAC'99, New York 1999. p. 166.
2. Miertusova · Vacuum · 1997 · 48 · 75110.1016/S0042-207X(97)00080-8 ↗
3. Miertusova J. Proceedings of the PAC'98, Stockholm, 1998. p. 49.
4. Mathewson A. Proceedings of the Workshop on Vacuum for Synchronous Light Sources, Orsay 1996. p. 25.
5. Miertusova J. Proceedings of EPAC'96, Barcelona-Sitges, 1996. p. 469.
6. Ishimaru H. MRS Bulletin 1990;15(7): p. 23.10.1557/S0883769400059212 ↗
7. Ushkov V. Private communication.
8. Benvenuti C. Private communication.