Effect of the magnetic field on the operation of ionisation gauges
Source abstract
Abstract
Hot cathode ionisation gauges are the only reliable pressure measurement devices suitable for both high and ultra-high vacuum measurement. These devices are characterized by low accuracy that is hardly better than 20%. The sources of loss of accuracy are documented in the literature although their quantification and details are not fully understood. In the present work, simulations of Bayard-Alpert and extractor gauges were performed under the influence of uniform magnetic fields up to 30 Gs. Results are in qualitative agreement with measurements taken previously with the Bayard-Alpert gauge. Both gauges are sensitive to low intensity magnetic fields which may be present in vacuum chambers. However, the extractor gauge proved to be more stable in the presence of a magnetic field due to its ring-shaped cathode.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Plasma Diagnostics and Applications · Advanced Sensor Technologies Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Total pressure vacuum gauges
2. Stable and reproducible Bayard-Alpert ionisation gauge10.1116/1.578837 ↗
3. Comparison of some metrological characteristics of hot and cold cathode ionisation gauges10.1016/S0042-207X(02)00781-9 ↗
4. Long-term stability of metal-envelope enclosed Bayard–Alpert ionization gauges10.1116/1.4750482 ↗
5. Comparison of hot cathode and cold cathode ionization gauges10.1116/1.577439 ↗
6. Ionization gauge errors at low pressures10.1116/1.581912 ↗
7. A review on hot cathode ionisation gauges with focus on a suitable design for measurement accuracy and stability10.1016/j.vacuum.2020.109545 ↗
8. Quantitative measurements of various gases in high and ultrahigh vacuum10.1116/1.5018210 ↗
9. Influence of ion induced secondary electron emission on the stability of ionisation vacuum gauges10.1016/j.vacuum.2020.109907 ↗
10. New x‐ray limit measurements for extractor gauges10.1116/1.577192 ↗
11. New hot-filament ionization gauge with low residual current10.1116/1.1492470 ↗
12. The application of ion storage in electron space-charge fields to the design of a U.H.V. gauge and mass-spectrometer ion source
13. Development of a design for an ionisation vacuum gauge suitable as a reference standard10.1016/j.vacuum.2020.109884 ↗
14. Electrons on a straight path: a novel ionisation vacuum gauge suitable as reference standard10.1016/j.vacuum.2021.110239 ↗
15. Calibration and characterization of Bayard–Alpert gauges operating in high magnetic fields10.1116/1.573967 ↗
16. Miertusova · 1998
17. Haas · 1998
18. The effect of magnetic field on the performance of Bayard-Alpert gauges10.1116/1.571364 ↗
19. 3D-Simulation of a Bayard Alpert ionisation gauge using SIMION program10.1016/j.vacuum.2019.03.039 ↗
20. 3D-simulation of ionisation gauges and comparison with measurements10.1016/j.vacuum.2016.12.014 ↗
21. Novel ionisation vacuum gauge suitable as a reference standard: influence of primary electron trajectories on the operation10.1016/j.vacuum.2022.111041 ↗
22. Simulation of an extractor ionisation gauge
23. A database of electron-impact ionization cross sections of molecules composed of H, C, N, O, and F10.1063/5.0054342 ↗