journal article·2020-01

Dynamic response characteristics of vacuum pressure measurement system with pneumatic long-thin tube

Longlong Gao, Jinlong Hu, Jingmin Du, Baoren Li

Vacuum· Volume 171
Publisher page

Abstract

Abstract The pneumatic long-thin tube between a measured pressure source and pressure sensor is a key component of a vacuum pressure measurement system (VPMS). The dynamic response characteristics of a pneumatic long-thin tube significantly affects the accuracy of the VPMS. This paper presents a mathematical model of the pressure propagation in a VPMS. The mathematical model accounts for the effects of fluid viscosity and heat transfer. A method for testing dynamic response characteristics of the VPMS is proposed. The sinusoidal vacuum pressure signal source was generated by a device consisting of a closed chamber and a loudspeaker. A series of tests were carried out using pneumatic long-thin tube with diameters of 2 and 3 mm, lengths of 100 and 300 mm, and initial vacuum pressures of 3.3 and 30 kPa. The comparison of the experimental and mathematical simulation results demonstrated that the mathematical model could accurately describe the dynamic response characteristics of the VPMS within certain frequency and pressure ranges. The results of this paper have general implications for the design and analysis of the VPMSs.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Sensor Technologies Research · Scientific Measurement and Uncertainty Evaluation · Flow Measurement and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Measurement of the pressure differences in a large chamber where the pressure is generated dynamically10.1016/S0042-207X(02)00222-1 ↗
2. A capillary manometer for pressure measurements in small cavities10.1016/j.vacuum.2016.12.019 ↗
3. A comparative study of emissive probe techniques for vacuum space potential measurements10.1016/j.vacuum.2018.06.061 ↗
4. High vacuum measurements and calibrations, molecular flow fluid transient effects10.1016/j.vacuum.2015.04.030 ↗
5. Design of directional probes for high-frequency turbine measurements10.1115/1.4037640 ↗
6. Response time of a pressure measurement system with a connecting tube10.1080/10739140701436579 ↗
7. The response time of wind tunnel pressure measuring systems
8. Interferometric techniques for fundamental static or dynamic pressure measurements and transducer calibration10.1088/0022-3735/10/12/022 ↗
9. Flight evaluation of a pneumatic system for unsteady pressure measurements using conventional sensors
10. Bergh · 1965 · 217
11. Optimal dimensions of connecting tubes for dynamic measurements of pressure10.1088/1742-6596/1065/16/162006 ↗
12. Dynamic pressure generator for dynamic calibrations at different average pressures based on a double-acting pneumatic actuator10.1016/j.sna.2016.05.031 ↗
13. Investigation of polytropic corrections for the piston-in-cylinder primary standard used in dynamic calibrations of pressure sensors10.1016/j.sna.2018.03.019 ↗
14. Novel method for estimating the dynamic characteristics of pressure sensor in shock tube calibration test10.1063/1.4921853 ↗
15. Development of a dynamic pressure generator based on a loudspeaker with improved frequency characteristics10.1016/j.measurement.2018.03.038 ↗
16. Characteristics of a dynamic pressure generator based on loudspeakers10.1016/j.sna.2011.03.037 ↗
17. On the transient of pressure waves in ducts for systems operating in industrial automation10.1115/1.4000652 ↗
18. A practical model for pressure probe system response estimation (with review of existing models)10.1088/1361-6501/aaa58f ↗
19. An experimental and theoretical investigation of wave propagation in teflon and nylon tubing with methods to prevent aliasing in pressure scanners10.1115/1.4025004 ↗
20. A new tubing system for the measurement of fluctuating pressures10.1016/0167-6105(87)90026-2 ↗
21. Compensating for pneumatic distortion in pressure sensing devices
22. A high efficient method for calibration and compensation of digital air pressure sensor
23. Dynamic calibration of low-range silicon pressure sensors
24. H. Kobayashi, T. Leger, J.M. Wolff, Experimental and theoretical frequency response of pressure transducers for high speed turbomachinery, 34th AIAA/ASME/SAE/ASEE Joint Propul-Sion Meeting..
25. Improved accuracy, second-order response model for pressure sensing systems10.2514/1.36262 ↗
26. On the theory of the frequency response of gas and liquid pressure measurement systems with connecting tubes10.1088/1361-6501/aae884 ↗
27. Zhang · 1987
28. Application of digital filtering techniques to unsteady pressure measurements
29. Prediction of the dynamic response of complex transmission line systems for unsteady pressure measurements10.1088/0957-0233/19/12/125401 ↗
30. Optimization design of pulsating wind pressure measuring system
31. Cai · 1990